메뉴 건너뛰기




Volumn 53, Issue 13, 2008, Pages

Off-resonance positive contrast imaging of a passive endomyocardial catheter in swine

Author keywords

[No Author keywords available]

Indexed keywords

CATHETERS; HEALTH; IMAGING TECHNIQUES; MEDICAL IMAGING; RESONANCE;

EID: 47649129463     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/13/N02     Document Type: Article
Times cited : (5)

References (16)
  • 4
    • 34248993948 scopus 로고    scopus 로고
    • Factors influencing fast low angle positive contrast steady-state free precession (FLAPS) magnetic resonance imaging
    • Dharmakumar R, Koktzoglou I and Li D 2007 Factors influencing fast low angle positive contrast steady-state free precession (FLAPS) magnetic resonance imaging Phys. Med. Biol. 52 3261-73
    • (2007) Phys. Med. Biol. , vol.52 , Issue.11 , pp. 3261-3273
    • Dharmakumar, R.1    Koktzoglou, I.2    Li, D.3
  • 5
    • 33747595007 scopus 로고    scopus 로고
    • Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: Theory and proof-of-principle experiments
    • Dharmakumar R, Koktzoglou I and Li D 2006 Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: theory and proof-of-principle experiments Phys. Med. Biol. 51 4201-15
    • (2006) Phys. Med. Biol. , vol.51 , Issue.17 , pp. 4201-4215
    • Dharmakumar, R.1    Koktzoglou, I.2    Li, D.3
  • 6
    • 34250378761 scopus 로고    scopus 로고
    • Dephased FLAPS for improved visualization of susceptibility-shifted passive devices for real-time interventional MRI
    • Koktzoglou I, Li D and Dharmakumar R 2007 Dephased FLAPS for improved visualization of susceptibility-shifted passive devices for real-time interventional MRI Phys. Med. Biol. 52 N277-86
    • (2007) Phys. Med. Biol. , vol.52 , Issue.13
    • Koktzoglou, I.1    Li, D.2    Dharmakumar, R.3
  • 8
    • 30344439136 scopus 로고    scopus 로고
    • Gradient echo acquisition for superparamagnetic particles with positive contrast (GRASP): Sequence characterization in membrane and glass superparamagnetic iron oxide phantoms at 1.5T and 3T
    • Mani V, Briley-Saebo K C, Itskovich V V, Samber D D and Fayad Z A 2006a Gradient echo acquisition for superparamagnetic particles with positive contrast (GRASP): sequence characterization in membrane and glass superparamagnetic iron oxide phantoms at 1.5T and 3T Magn. Reson. Med. 55 126-35
    • (2006) Magn. Reson. Med. , vol.55 , Issue.1 , pp. 126-135
    • Mani, V.1    Briley-Saebo, K.C.2    Itskovich, V.V.3    Samber, D.D.4    Fayad, Z.A.5
  • 9
    • 33750624038 scopus 로고    scopus 로고
    • Feasibility of in vivo identification of endogenous ferritin with positive contrast MRI in rabbit carotid crush injury using GRASP
    • Mani V, Briley-Saebo K C, Hyafil F and Fayad Z A 2006b Feasibility of in vivo identification of endogenous ferritin with positive contrast MRI in rabbit carotid crush injury using GRASP Magn. Reson. Med. 56 1096-106
    • (2006) Magn. Reson. Med. , vol.56 , Issue.5 , pp. 1096-1106
    • Mani, V.1    Briley-Saebo, K.C.2    Hyafil, F.3    Fayad, Z.A.4
  • 10
    • 31944448891 scopus 로고    scopus 로고
    • A polymer-based MR-compatible guidewire: A study to explore new prospects for interventional peripheral magnetic resonance angiography (ipMRA)
    • Mekle R, Hofmann E, Scheffler K and Bilecen D 2006 A polymer-based MR-compatible guidewire: a study to explore new prospects for interventional peripheral magnetic resonance angiography (ipMRA) J. Magn. Reson. Imaging 23 145-55
    • (2006) J. Magn. Reson. Imaging , vol.23 , Issue.2 , pp. 145-155
    • Mekle, R.1    Hofmann, E.2    Scheffler, K.3    Bilecen, D.4
  • 11
    • 0035172358 scopus 로고    scopus 로고
    • On the heating of linear conductive structures as guide wires and catheters in interventional MRI
    • Nitz W R, Oppelt A, Renz W, Manke C, Lenhart M and Link J 2001 On the heating of linear conductive structures as guide wires and catheters in interventional MRI J. Magn. Reson. Imaging 13 105-14
    • (2001) J. Magn. Reson. Imaging , vol.13 , Issue.1 , pp. 105-114
    • Nitz, W.R.1    Oppelt, A.2    Renz, W.3    Manke, C.4    Lenhart, M.5    Link, J.6
  • 14
    • 0141840798 scopus 로고    scopus 로고
    • Passive tracking exploiting local signal conservation: The white marker phenomenon
    • Seppenwoolde J H, Viergever M A and Bakker C J 2003 Passive tracking exploiting local signal conservation: the white marker phenomenon Magn. Reson. Med. 50 784-90
    • (2003) Magn. Reson. Med. , vol.50 , Issue.4 , pp. 784-790
    • Seppenwoolde, J.H.1    Viergever, M.A.2    Bakker, C.J.3
  • 15
    • 36348997189 scopus 로고    scopus 로고
    • White-marker imaging-separating magnetic susceptibility effects from partial volume effects
    • Seppenwoolde J H, Vincken K L and Bakker C J 2007 White-marker imaging-separating magnetic susceptibility effects from partial volume effects Magn. Reson. Med. 58 605-9
    • (2007) Magn. Reson. Med. , vol.58 , Issue.3 , pp. 605-609
    • Seppenwoolde, J.H.1    Vincken, K.L.2    Bakker, C.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.