메뉴 건너뛰기




Volumn 53, Issue 14, 2008, Pages 3723-3738

Measured count-rate performance of the Discovery STE PET/CT scanner in 2D, 3D and partial collimation acquisition modes

Author keywords

[No Author keywords available]

Indexed keywords

ARSENIC COMPOUNDS; COMPUTATIONAL METHODS; COMPUTER SIMULATION; FORECASTING; HEALTH; MERGERS AND ACQUISITIONS; SCANNING; STANDARDS; THREE DIMENSIONAL;

EID: 47649124206     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/14/002     Document Type: Article
Times cited : (32)

References (23)
  • 3
    • 0142095006 scopus 로고    scopus 로고
    • Brain lesion detectability studies with a high resolution PET operation in no-septa and partial-septa configurations
    • Baghaei H, Wong W-H, Uribe J, Li H, Aykac M, Wang Y, Liu Y, Xing T and Farrel R 2003 Brain lesion detectability studies with a high resolution PET operation in no-septa and partial-septa configurations IEEE Trans. Nucl. Sci. 50 1364-9
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1364-1369
    • Baghaei, H.1    Wong, W.-H.2    Uribe, J.3    Li, H.4    Aykac, M.5    Wang, Y.6    Liu, Y.7    Xing, T.8    Farrel, R.9
  • 5
    • 84939045331 scopus 로고
    • A multi-crystal two dimensional BGO detector system for positron emission tomography
    • Casey M E and Nutt R 1986 A multi-crystal two dimensional BGO detector system for positron emission tomography IEEE Trans. Nucl. Sci. 33 460-3
    • (1986) IEEE Trans. Nucl. Sci. , vol.33 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2
  • 11
    • 45849135565 scopus 로고    scopus 로고
    • Performance evaluation of an integrated PET/CT scanner: Discovery STE
    • Kinahan P E et al 2006 Performance evaluation of an integrated PET/CT scanner: discovery STE J. Nucl. Med. 47 392P (abstract)
    • (2006) J. Nucl. Med. , vol.47
    • Kinahan, P.E.1    Al, E.2
  • 12
    • 0036731951 scopus 로고    scopus 로고
    • Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET
    • Lartizien C, Comtat C, Kinahan P E, Ferreira N, Bendriem B and Trebossen R 2002 Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET J. Nucl. Med. 43 1268-78
    • (2002) J. Nucl. Med. , vol.43 , Issue.9 , pp. 1268-1278
    • Lartizien, C.1    Comtat, C.2    Kinahan, P.E.3    Ferreira, N.4    Bendriem, B.5    Trebossen, R.6
  • 13
    • 2542474417 scopus 로고    scopus 로고
    • A lesion detection observer study comparing 2D versus fully-3D whole-body PET imaging protocols
    • Lartizien C, Kinahan P E and Comtat C 2004 A lesion detection observer study comparing 2D versus fully-3D whole-body PET imaging protocols J. Nucl. Med. 45 714-23
    • (2004) J. Nucl. Med. , vol.45 , Issue.4 , pp. 714-723
    • Lartizien, C.1    Kinahan, P.E.2    Comtat, C.3
  • 17
    • 0033024060 scopus 로고    scopus 로고
    • Capabilities of two- and three-dimensional FDG-PET for detecting small lesions and lymph nodes in the upper torso: A dynamic phantom study
    • Raylman R R, Kison P V and Wahl R L 1999 Capabilities of two- and three-dimensional FDG-PET for detecting small lesions and lymph nodes in the upper torso: a dynamic phantom study Eur. J. Nucl. Med. 26 39-45
    • (1999) Eur. J. Nucl. Med. , vol.26 , Issue.1 , pp. 39-45
    • Raylman, R.R.1    Kison, P.V.2    Wahl, R.L.3
  • 18
    • 0037459552 scopus 로고    scopus 로고
    • Survey of parallel slat collimator designs for hybrid PET imaging
    • Rust T C and Kadrmas D J 2003 Survey of parallel slat collimator designs for hybrid PET imaging Phys. Med. Biol. 48 N97-104
    • (2003) Phys. Med. Biol. , vol.48 , Issue.6 , pp. 97-104
    • Rust, T.C.1    Kadrmas, D.J.2
  • 19
    • 34547291283 scopus 로고    scopus 로고
    • Optimization of noise equivalent count rate performance for a partially collimated PET scanner by varying the number of septa
    • Schmitz R E, Harrison R L, Stearns C W, Lewellen T K and Kinahan P E 2007 Optimization of noise equivalent count rate performance for a partially collimated PET scanner by varying the number of septa IEEE Trans. Med. Imaging 26 935-44
    • (2007) IEEE Trans. Med. Imaging , vol.26 , Issue.7 , pp. 935-944
    • Schmitz, R.E.1    Harrison, R.L.2    Stearns, C.W.3    Lewellen, T.K.4    Kinahan, P.E.5
  • 21
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using noise equivalent counts
    • Strother S C, Casey M E and Hoffman E J 1990 Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using noise equivalent counts IEEE Trans. Nucl. Sci. 37 783-8
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , Issue.2 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 22
    • 0033776439 scopus 로고    scopus 로고
    • A 2D/3D hybrid PET scanner with rotating partial slice-septa and its quantitative procedures
    • Tanaka E, Hasegawa T, Yamashita T, Okada H and Murayama H 2000 A 2D/3D hybrid PET scanner with rotating partial slice-septa and its quantitative procedures Phys. Med. Biol. 45 2821-41
    • (2000) Phys. Med. Biol. , vol.45 , Issue.10 , pp. 2821-2841
    • Tanaka, E.1    Hasegawa, T.2    Yamashita, T.3    Okada, H.4    Murayama, H.5
  • 23
    • 0035020033 scopus 로고    scopus 로고
    • Comparison of 2-dimensional and 3-dimensional cardiac 82Rb PET studies
    • Votaw J R and White M 2001 Comparison of 2-dimensional and 3-dimensional cardiac 82Rb PET studies J. Nucl. Med. 42 701-6
    • (2001) J. Nucl. Med. , vol.42 , Issue.5 , pp. 701-706
    • Votaw, J.R.1    White, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.