메뉴 건너뛰기




Volumn 55, Issue 3, 2008, Pages 975-983

Image reconstruction for a partially collimated whole body PET scanner

Author keywords

2.5D; Collimation; Fully 3 d PET; Normalization; Scatter estimation; Septa

Indexed keywords

ACOUSTIC EMISSIONS; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; MEDICAL IMAGING; PLASTIC BOTTLES; POSITRON ANNIHILATION SPECTROSCOPY; POSITRON EMISSION TOMOGRAPHY; REPAIR; RESTORATION;

EID: 45849098002     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2008.921938     Document Type: Conference Paper
Times cited : (2)

References (28)
  • 1
    • 0031987385 scopus 로고    scopus 로고
    • S. Pajevic, M. E. Daube-Witherspoon, S. L. Bacharach, and R. E. Carson, Noise characteristics of 3-D and 2-D PET images, IEEE Trans. Med. Imag., 1.7, no. 1, pp. 9-23, Jan. 1.998.
    • S. Pajevic, M. E. Daube-Witherspoon, S. L. Bacharach, and R. E. Carson, "Noise characteristics of 3-D and 2-D PET images," IEEE Trans. Med. Imag., vol. 1.7, no. 1, pp. 9-23, Jan. 1.998.
  • 2
    • 0142241181 scopus 로고    scopus 로고
    • Comparison of NEC and subjective image quality measures in 2D and 3D whole-body PET imaging
    • 3
    • S. D. Wollenweber, S. G. Kohlmyer, and C. W. Stearns, "Comparison of NEC and subjective image quality measures in 2D and 3D whole-body PET imaging," in Proc. IEEE Nucl. Sci. Symp. Conf. Record, 2002, vol. 3, pp. 1393-1396, vol. 3.
    • (2002) Proc. IEEE Nucl. Sci. Symp. Conf. Record , vol.3 , pp. 1393-1396
    • Wollenweber, S.D.1    Kohlmyer, S.G.2    Stearns, C.W.3
  • 3
    • 2542474417 scopus 로고    scopus 로고
    • A lesion detection observer study comparing 2-dimensional versus fully 3-dimensional whole-body PET imaging protocols
    • C. Lartizien, P. E. Kinahan, and C. Comtat, "A lesion detection observer study comparing 2-dimensional versus fully 3-dimensional whole-body PET imaging protocols," J. Nucl. Med., vol. 45, no. 4, pp. 714-723, 2004.
    • (2004) J. Nucl. Med , vol.45 , Issue.4 , pp. 714-723
    • Lartizien, C.1    Kinahan, P.E.2    Comtat, C.3
  • 4
    • 0001549484 scopus 로고
    • The effect of collimation on scatter fraction in multi-slice PET
    • Feb
    • C. J. Thompson, "The effect of collimation on scatter fraction in multi-slice PET," IEEE Trans. Nucl. Sci., vol. 35, no. 1, pp. 598-602, Feb. 1988.
    • (1988) IEEE Trans. Nucl. Sci , vol.35 , Issue.1 , pp. 598-602
    • Thompson, C.J.1
  • 5
    • 0024612105 scopus 로고
    • The effect of collimation on single rates in multi-slice PET
    • Feb
    • C. J. Thompson, "The effect of collimation on single rates in multi-slice PET," IEEE Trans. Nucl. Sci., vol. 36, no. 1, pp. 1072-1077, Feb. 1989.
    • (1989) IEEE Trans. Nucl. Sci , vol.36 , Issue.1 , pp. 1072-1077
    • Thompson, C.J.1
  • 6
    • 0036816445 scopus 로고    scopus 로고
    • Septa design study for volumetric imaging in positron emission tomography
    • Oct
    • M. Aykac, J. Uribe, H. Baghaei, H. Li, Y. Wang, Y. Liu, T. Xing, and W.-H. Wong, "Septa design study for volumetric imaging in positron emission tomography," IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2097-2102, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.5 , pp. 2097-2102
    • Aykac, M.1    Uribe, J.2    Baghaei, H.3    Li, H.4    Wang, Y.5    Liu, Y.6    Xing, T.7    Wong, W.-H.8
  • 7
    • 38649140203 scopus 로고    scopus 로고
    • Count-rate performance of the discovery STE PET scanner using partial collimation
    • presented at the, Record
    • L. R. MacDonald et al., "Count-rate performance of the discovery STE PET scanner using partial collimation," presented at the IEEE Nucl. Sci. Symp. Conf. Record, 2006.
    • (2006) IEEE Nucl. Sci. Symp. Conf
    • MacDonald, L.R.1
  • 8
    • 34547291283 scopus 로고    scopus 로고
    • Optimization of noise equivalent count rate performance for a partially collimated PET scanner by varying the number of septa
    • Jul
    • R. E. Schmitz, R. L. Harrison, C. W. Stearns, T. K. Lewellen, and P. E. Kinahan, "Optimization of noise equivalent count rate performance for a partially collimated PET scanner by varying the number of septa," IEEE Trans. Med. Imag., vol. 26, no. 7, pp. 935-944, Jul. 2007.
    • (2007) IEEE Trans. Med. Imag , vol.26 , Issue.7 , pp. 935-944
    • Schmitz, R.E.1    Harrison, R.L.2    Stearns, C.W.3    Lewellen, T.K.4    Kinahan, P.E.5
  • 9
    • 0036816514 scopus 로고    scopus 로고
    • Optimization of septal spacing in hybrid PET using estimation task performance
    • Oct
    • S. J. Glick, C. J. Groiselle, J. Kolthammer, and R. Z. Stodilka, "Optimization of septal spacing in hybrid PET using estimation task performance," IEEE Trans. Nucl., Sci., vol. 49, no. 5, pp. 2127-2132, Oct. 2002.
    • (2002) IEEE Trans. Nucl., Sci , vol.49 , Issue.5 , pp. 2127-2132
    • Glick, S.J.1    Groiselle, C.J.2    Kolthammer, J.3    Stodilka, R.Z.4
  • 10
    • 0029006731 scopus 로고
    • Collimator optimization for lesion detection incorporating prior information about lesion size
    • S. C. Moore, D. J. deVries, B. Nandram, M. F. Kijewski, and S. P. Mueller, "Collimator optimization for lesion detection incorporating prior information about lesion size," Med Phys., vol. 22, no. 6, pp. 703-713, 1995.
    • (1995) Med Phys , vol.22 , Issue.6 , pp. 703-713
    • Moore, S.C.1    deVries, D.J.2    Nandram, B.3    Kijewski, M.F.4    Mueller, S.P.5
  • 11
    • 0037459552 scopus 로고    scopus 로고
    • Survey of parallel slat collimator designs for hybrid PET imaging
    • T. C. Rust and D. J. Kadrmas, "Survey of parallel slat collimator designs for hybrid PET imaging," Phys. Med. Biol., vol. 48, no. 6, pp. N97-N104, 2003.
    • (2003) Phys. Med. Biol , vol.48 , Issue.6
    • Rust, T.C.1    Kadrmas, D.J.2
  • 13
    • 0142095006 scopus 로고    scopus 로고
    • Brain lesion detectability studies with a high resolution PET operating in no-septa and partial-septa configurations
    • Oct
    • H. Baghaei et al., "Brain lesion detectability studies with a high resolution PET operating in no-septa and partial-septa configurations," IEEE Trans. Nucl. Sci., vol. 50, no. 5, pp. 1364-1369, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , Issue.5 , pp. 1364-1369
    • Baghaei, H.1
  • 15
    • 0036816760 scopus 로고    scopus 로고
    • A Monte Carlo simulation study on coarse septa for scatter correction in 3-D PET
    • Oct
    • T. Hasegawa, E. Tanaka, T. Yamashita, M. Watanabe, T. Yamaya, and H. Murayama, "A Monte Carlo simulation study on coarse septa for scatter correction in 3-D PET," IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2133-2138, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.5 , pp. 2133-2138
    • Hasegawa, T.1    Tanaka, E.2    Yamashita, T.3    Watanabe, M.4    Yamaya, T.5    Murayama, H.6
  • 16
    • 45849135565 scopus 로고    scopus 로고
    • Performance evaluation of an integrated PET/CT scanner: Discovery STE
    • P. E. Kinahan et al., "Performance evaluation of an integrated PET/CT scanner: Discovery STE," in J. Nucl. Med., 2006, vol. 46, p. 392P.
    • (2006) J. Nucl. Med , vol.46
    • Kinahan, P.E.1
  • 18
    • 45849107925 scopus 로고    scopus 로고
    • Performance measurements of positron emission tomographs, National Electrical Manufacturers Association
    • NEMA standards publication NU 2-2001:, Tech. Rep, 200.1, National Electrical. Manufacturers Association
    • NEMA standards publication NU 2-2001: Performance measurements of positron emission tomographs, National Electrical Manufacturers Association, Tech. Rep., 200.1, National Electrical. Manufacturers Association, .
  • 19
    • 0022888626 scopus 로고    scopus 로고
    • M. E. Casey and E. J. Hoffman, Quantitation in positron emission computed tomography: 7. A technique to reduce noise in accidental, coincidence measurements and coincidence efficiency calibration., J. Comput. Assist., 1.0, no. 5, pp. 845-850, 1986.
    • M. E. Casey and E. J. Hoffman, "Quantitation in positron emission computed tomography: 7. A technique to reduce noise in accidental, coincidence measurements and coincidence efficiency calibration.," J. Comput. Assist., vol. 1.0, no. 5, pp. 845-850, 1986.
  • 20
    • 0024610834 scopus 로고
    • PET system calibrations and corrections for quantitative and spatially accurate images
    • Feb
    • E. J. Hoffman, T. M. Guerrero, G. Germano, W. M. Digby, and M. Dahlbom, "PET system calibrations and corrections for quantitative and spatially accurate images," IEEE Trans. Nucl. Sci., vol. 36, no. 1, pp. 1108-1112, Feb. 1989.
    • (1989) IEEE Trans. Nucl. Sci , vol.36 , Issue.1 , pp. 1108-1112
    • Hoffman, E.J.1    Guerrero, T.M.2    Germano, G.3    Digby, W.M.4    Dahlbom, M.5
  • 22
    • 0033776439 scopus 로고    scopus 로고
    • A 2D/3D hybrid PET scanner with rotating partial slice-septa and its quantitative procedures
    • E. Tanaka, T. Hasegawa, T. Yamashita, H. Okada, and H. Murayama, "A 2D/3D hybrid PET scanner with rotating partial slice-septa and its quantitative procedures," Phys. Med. Biol., vol. 45, no. 10, pp. 2821-2841, 2000.
    • (2000) Phys. Med. Biol , vol.45 , Issue.10 , pp. 2821-2841
    • Tanaka, E.1    Hasegawa, T.2    Yamashita, T.3    Okada, H.4    Murayama, H.5
  • 23
    • 0031913792 scopus 로고    scopus 로고
    • Algorithms for calculating detector efficiency normalization coefficients for true coincidences in 3D PET
    • R. D. Badawi, M. A. Lodge, and P. K. Marsden, "Algorithms for calculating detector efficiency normalization coefficients for true coincidences in 3D PET," Phys. Med. Biol., vol. 43, no. 1, pp. 189-205, 1998.
    • (1998) Phys. Med. Biol , vol.43 , Issue.1 , pp. 189-205
    • Badawi, R.D.1    Lodge, M.A.2    Marsden, P.K.3
  • 24
    • 0030067225 scopus 로고    scopus 로고
    • Model-based scatter correction for fully 3D PET
    • J. M. Ollinger, "Model-based scatter correction for fully 3D PET," Phys. Med. Biol., vol. 41, pp. 153-176, 1996.
    • (1996) Phys. Med. Biol , vol.41 , pp. 153-176
    • Ollinger, J.M.1
  • 25
    • 0036624451 scopus 로고    scopus 로고
    • Parameterization of a model-based 3-D PET scatter correction
    • Jun
    • S. D. Wollenweber, "Parameterization of a model-based 3-D PET scatter correction," IEEE Trans. Nucl. Sci., vol. 49, no. 3, pp. 722-727, Jun. 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.3 , pp. 722-727
    • Wollenweber, S.D.1
  • 26
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection, data
    • Apr
    • H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection, data," IEEE Trans. Med. Imag., vol. 13, no. 4, pp. 601-609, Apr. 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , Issue.4 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 28
    • 0029357131 scopus 로고
    • Detector efficiency and compton scatter in fully 3D PET
    • Aug
    • J. M. Ollinger, "Detector efficiency and compton scatter in fully 3D PET," IEEE Trans. Nucl. Sci., vol. 42, no. 4, pp. 1168-1173, Aug. 1995.
    • (1995) IEEE Trans. Nucl. Sci , vol.42 , Issue.4 , pp. 1168-1173
    • Ollinger, J.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.