메뉴 건너뛰기




Volumn 39, Issue 7, 2008, Pages 2105-2113

Asymmetric vascular stent: Feasibility study of a new low-porosity patch-containing stent

Author keywords

Canine model; Neurysm; Stent; Time density curve

Indexed keywords

ANGIOGRAPHY; ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BLEEDING; BLOOD VESSEL GRAFT; CAROTID ARTERY; CAROTID ARTERY OBSTRUCTION; CONTROLLED STUDY; DOG; FEASIBILITY STUDY; HISTOPATHOLOGY; INTIMA; INTRACRANIAL ANEURYSM; MICRO-COMPUTED TOMOGRAPHY; NONHUMAN; PRIORITY JOURNAL; STENT; THROMBOGENESIS; ANIMAL; BLOOD VESSEL PROSTHESIS; COHORT ANALYSIS; COMPUTER ASSISTED TOMOGRAPHY; CONE BEAM COMPUTED TOMOGRAPHY; EQUIPMENT DESIGN; HEMODYNAMICS; METHODOLOGY; PATHOLOGY; POROSITY; PROBABILITY;

EID: 47649084858     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/STROKEAHA.107.503862     Document Type: Article
Times cited : (31)

References (27)
  • 1
    • 0347624003 scopus 로고    scopus 로고
    • Double-stent method: Therapeutic alternative for small wide-necked aneurysms
    • Doerfler A, Wanke I, Egelhof T, Stolke D, Forsting M. Double-stent method: Therapeutic alternative for small wide-necked aneurysms. J Neurosurg. 2004;100:150-154.
    • (2004) J Neurosurg , vol.100 , pp. 150-154
    • Doerfler, A.1    Wanke, I.2    Egelhof, T.3    Stolke, D.4    Forsting, M.5
  • 2
    • 33745407539 scopus 로고    scopus 로고
    • Flow modification in canine intracranial aneurysm model by an asymmetric stent: Studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses
    • Hoi Y, Ionita CN, Tranquebar RV, Hoffmann KR, Woodward SH, Taulbee DB, Meng H, Rudin S. Flow modification in canine intracranial aneurysm model by an asymmetric stent: Studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses. Proc SPIE. 2006;6143:61430J.
    • (2006) Proc SPIE , vol.6143
    • Hoi, Y.1    Ionita, C.N.2    Tranquebar, R.V.3    Hoffmann, K.R.4    Woodward, S.H.5    Taulbee, D.B.6    Meng, H.7    Rudin, S.8
  • 3
    • 3042601839 scopus 로고    scopus 로고
    • Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents
    • Ionita CN, Hoi Y, Meng H, Rudin S. Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents. Proc SPIE. 2004;5369:295-306.
    • (2004) Proc SPIE , vol.5369 , pp. 295-306
    • Ionita, C.N.1    Hoi, Y.2    Meng, H.3    Rudin, S.4
  • 4
    • 34548250908 scopus 로고    scopus 로고
    • A new endoluminal, flow-disrupting device for treatment of saccular aneurysms
    • Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA, Cloft HJ. A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke. 2007;38:2346-2352.
    • (2007) Stroke , vol.38 , pp. 2346-2352
    • Kallmes, D.F.1    Ding, Y.H.2    Dai, D.3    Kadirvel, R.4    Lewis, D.A.5    Cloft, H.J.6
  • 6
    • 0036286337 scopus 로고    scopus 로고
    • The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms
    • Lieber BB, Gounis MJ. The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms. Neurol Res. 2002;24:S33-S42.
    • (2002) Neurol Res , vol.24
    • Lieber, B.B.1    Gounis, M.J.2
  • 7
    • 33745346130 scopus 로고    scopus 로고
    • Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using computational fluid dynamic (CFD) calculations in the computed tomography (CT) derived lumen
    • Kim M, Ionita C, Tranquebar R, Hoffmann KR, Taulbee DB, Meng H, Rudin S. Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using computational fluid dynamic (CFD) calculations in the computed tomography (CT) derived lumen. Proc SPIE. 2006;6143:61432G.
    • (2006) Proc SPIE , vol.6143
    • Kim, M.1    Ionita, C.2    Tranquebar, R.3    Hoffmann, K.R.4    Taulbee, D.B.5    Meng, H.6    Rudin, S.7
  • 9
    • 0036677287 scopus 로고    scopus 로고
    • Angiographic quantification of contrast medium washout from cerebral aneu- brysms after stent placement
    • Sadasivan C, Lieber BB, Gounis MJ, Lopes DK, Hopkins LN. Angiographic quantification of contrast medium washout from cerebral aneu- brysms after stent placement. AJNR Am J Neuroradiol. 2002;23: 1214-1221.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1214-1221
    • Sadasivan, C.1    Lieber, B.B.2    Gounis, M.J.3    Lopes, D.K.4    Hopkins, L.N.5
  • 10
    • 3042635196 scopus 로고    scopus 로고
    • Angiographic analysis of blood flow modification in cerebral aneurysm models with a new asymmetric stent
    • Wang Z, Ionita CN, Rudin S, Hoffmann KR, Paxton AB, Bednarek DR. Angiographic analysis of blood flow modification in cerebral aneurysm models with a new asymmetric stent. Proc SPIE. 2004;5369:307-318.
    • (2004) Proc SPIE , vol.5369 , pp. 307-318
    • Wang, Z.1    Ionita, C.N.2    Rudin, S.3    Hoffmann, K.R.4    Paxton, A.B.5    Bednarek, D.R.6
  • 11
    • 0032773494 scopus 로고    scopus 로고
    • A steady flow analysis on the stented and non-stented sidewall aneurysm models
    • Yu SCM, Zhao JB. A steady flow analysis on the stented and non-stented sidewall aneurysm models. Med Eng Phys. 1999;21:133-141.
    • (1999) Med Eng Phys , vol.21 , pp. 133-141
    • Yu, S.C.M.1    Zhao, J.B.2
  • 12
    • 0035982808 scopus 로고    scopus 로고
    • Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow
    • Lieber BB, Livescu V, Hopkins LN, Wakhloo AK. Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow. Ann Biomed Eng. 2002;30:768-777.
    • (2002) Ann Biomed Eng , vol.30 , pp. 768-777
    • Lieber, B.B.1    Livescu, V.2    Hopkins, L.N.3    Wakhloo, A.K.4
  • 13
    • 0036629467 scopus 로고    scopus 로고
    • Changes of flow characteristics by stenting in aneurysm models: Influence of aneurysm geometry and stent porosity
    • Rhee K, Han MH, Cha SH. Changes of flow characteristics by stenting in aneurysm models: Influence of aneurysm geometry and stent porosity. Ann Biomed Eng. 2002;30:894-904.
    • (2002) Ann Biomed Eng , vol.30 , pp. 894-904
    • Rhee, K.1    Han, M.H.2    Cha, S.H.3
  • 14
    • 23244467460 scopus 로고    scopus 로고
    • Microangiographic image-guided localization of a new asymmetric stent for treatment of cerebral aneurysms
    • Ionita CN, Rudin S, Hoffmann KR, Bednarek DR. Microangiographic image-guided localization of a new asymmetric stent for treatment of cerebral aneurysms. Proc SPIE. 2005;5744:354-365.
    • (2005) Proc SPIE , vol.5744 , pp. 354-365
    • Ionita, C.N.1    Rudin, S.2    Hoffmann, K.R.3    Bednarek, D.R.4
  • 15
    • 33644847894 scopus 로고    scopus 로고
    • Characterization of cerebral aneurysms for assessing risk of rupture by using patient-specific computational hemodynamics models
    • Cebral JR, Castro MA, Burgess JE, Pergolizzi RS, Sheridan MJ, Putman CM. Characterization of cerebral aneurysms for assessing risk of rupture by using patient-specific computational hemodynamics models. AJNR Am J Neuroradiol. 2005;26:2550-2559.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 2550-2559
    • Cebral, J.R.1    Castro, M.A.2    Burgess, J.E.3    Pergolizzi, R.S.4    Sheridan, M.J.5    Putman, C.M.6
  • 19
    • 0024371608 scopus 로고
    • Measurement of absolute flow-rate in vessels using a stereoscopic DSA system
    • Fencil LE, Doi K, Chua KG, Hoffmann KR. Measurement of absolute flow-rate in vessels using a stereoscopic DSA system. Phys Med Biol. 1989;34:659-671.
    • (1989) Phys Med Biol , vol.34 , pp. 659-671
    • Fencil, L.E.1    Doi, K.2    Chua, K.G.3    Hoffmann, K.R.4
  • 20
    • 0033805467 scopus 로고    scopus 로고
    • X-ray video-densitometric methods for blood flow and velocity measurement: A critical review of literature
    • Shpilfoygel SD, Close RA, Valentino DJ, Duckwiler GR. X-ray video-densitometric methods for blood flow and velocity measurement: A critical review of literature. Med Phys. 2000;27:2008-2023.
    • (2000) Med Phys , vol.27 , pp. 2008-2023
    • Shpilfoygel, S.D.1    Close, R.A.2    Valentino, D.J.3    Duckwiler, G.R.4
  • 21
    • 0032231768 scopus 로고    scopus 로고
    • Evaluation of intraaneurysmal blood velocity by time-density curve analysis and digital subtraction angiography
    • Tenjin H, Asakura F, Nakahara Y, Matsumoto K, Matsuo T, Urano F, Ueda S. Evaluation of intraaneurysmal blood velocity by time-density curve analysis and digital subtraction angiography. AJNR Am J Neuroradiol. 1998;19:1303-1307.
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 1303-1307
    • Tenjin, H.1    Asakura, F.2    Nakahara, Y.3    Matsumoto, K.4    Matsuo, T.5    Urano, F.6    Ueda, S.7
  • 25
    • 33749681312 scopus 로고    scopus 로고
    • Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: Implications of intravascular stenting
    • Meng H, Wang Z, Kim M, Ecker RD, Hopkins LN. Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: Implications of intravascular stenting. AJNR Am J Neuroradiol. 2006;27: 1861-1865.
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1861-1865
    • Meng, H.1    Wang, Z.2    Kim, M.3    Ecker, R.D.4    Hopkins, L.N.5
  • 27
    • 33845927554 scopus 로고    scopus 로고
    • Method to rotate an endovascular device around the axis of a vessel using an external magnetic field
    • Florin E, Rangwala HS, Rudin S. Method to rotate an endovascular device around the axis of a vessel using an external magnetic field. Med Phys. 2007;34:328-333.
    • (2007) Med Phys , vol.34 , pp. 328-333
    • Florin, E.1    Rangwala, H.S.2    Rudin, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.