메뉴 건너뛰기




Volumn 231, Issue 1, 2004, Pages 272-276

Measurement of Flow Modification in Phantom Aneurysm Model: Comparison of Coils and a Longitudinally and Axially Asymmetric Stent - Initial Findings

Author keywords

Aneurysm, cerebral; Aneurysm, therapy; Angiography; Blood; Experimental study; Flow dynamics; Phantoms; Stents and prostheses

Indexed keywords

ANEURYSM SURGERY; ARTICLE; BRAIN ARTERY ANEURYSM; COIL; FLOW; IMAGE ANALYSIS; INTERMETHOD COMPARISON; PHANTOM; PRIORITY JOURNAL; STENT; SURGICAL INSTRUMENT; TREATMENT OUTCOME; VORTEX MOTION;

EID: 12144289923     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2311021741     Document Type: Article
Times cited : (44)

References (16)
  • 2
    • 0035199676 scopus 로고    scopus 로고
    • Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using a computerized tomography angiogram as a mold
    • Tateshima S, Murayama Y, Villablanca JP, et al. Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using a computerized tomography angiogram as a mold. J Neurosurg 2001; 95:1020-1027.
    • (2001) J Neurosurg , vol.95 , pp. 1020-1027
    • Tateshima, S.1    Murayama, Y.2    Villablanca, J.P.3
  • 3
    • 0034738138 scopus 로고    scopus 로고
    • Prevention of rat cerebral aneurysm formation by inhibition of nitric oxide synthase
    • Fukuda S, Hashimoto N, Naritomi H, et al. Prevention of rat cerebral aneurysm formation by inhibition of nitric oxide synthase. Circulation 2000; 101:2532-2538.
    • (2000) Circulation , vol.101 , pp. 2532-2538
    • Fukuda, S.1    Hashimoto, N.2    Naritomi, H.3
  • 4
    • 1842296356 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of acute intracranial aneurysms: Perioperative anatomical and clinical outcome in 403 patients
    • Vinuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysms: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997; 86:475-482.
    • (1997) J Neurosurg , vol.86 , pp. 475-482
    • Vinuela, F.1    Duckwiler, G.2    Mawad, M.3
  • 5
    • 0033709214 scopus 로고    scopus 로고
    • Neurovascular embolization: In vitro evaluation of a mechanical detachable platinum coil system
    • Murphy KJ, Mandai S, Gailloud P, et al. Neurovascular embolization: in vitro evaluation of a mechanical detachable platinum coil system. Radiology 2000; 217:904-906.
    • (2000) Radiology , vol.217 , pp. 904-906
    • Murphy, K.J.1    Mandai, S.2    Gailloud, P.3
  • 6
    • 0036125665 scopus 로고    scopus 로고
    • Unruptured intracranial aneurysms: A review
    • Weir B. Unruptured intracranial aneurysms: a review. J Neurosurg 2002; 96:3-42.
    • (2002) J Neurosurg , vol.96 , pp. 3-42
    • Weir, B.1
  • 7
    • 0032742470 scopus 로고    scopus 로고
    • Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils
    • Bavinzski G, Talazoglu V, Killer M, et al. Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils. J Neurosurg 1999; 91:284-293.
    • (1999) J Neurosurg , vol.91 , pp. 284-293
    • Bavinzski, G.1    Talazoglu, V.2    Killer, M.3
  • 8
    • 0032887656 scopus 로고    scopus 로고
    • Histologic evaluation of platinum coil embolization in an aneurysm model in rabbits
    • Kallmes DF, Helm GA, Hudson SB, et al. Histologic evaluation of platinum coil embolization in an aneurysm model in rabbits. Radiology 1999; 213:217-222.
    • (1999) Radiology , vol.213 , pp. 217-222
    • Kallmes, D.F.1    Helm, G.A.2    Hudson, S.B.3
  • 9
    • 0034912801 scopus 로고    scopus 로고
    • Aortic dissection: Percutaneous management with a separating stent-graft-preliminary results
    • Kang SG, Lee DY, Maeda M, et al. Aortic dissection: percutaneous management with a separating stent-graft-preliminary results. Radiology 2001; 220:533-539.
    • (2001) Radiology , vol.220 , pp. 533-539
    • Kang, S.G.1    Lee, D.Y.2    Maeda, M.3
  • 11
    • 0002968712 scopus 로고
    • Blood flow-induced remodeling of the artery wall
    • Bevan JA, Kaley G, Rubanyi GM, eds. New York, NY: Oxford University Press
    • Langille BL. Blood flow-induced remodeling of the artery wall. In: Bevan JA, Kaley G, Rubanyi GM, eds. Flow-dependent regulation of vascular function. New York, NY: Oxford University Press, 1995; 277-299.
    • (1995) Flow-dependent Regulation of Vascular Function , pp. 277-299
    • Langille, B.L.1
  • 13
    • 0026064241 scopus 로고
    • Determination of instantaneous and average blood flow rates from digital angiograms of vessel phantoms using distance-density curves
    • Hoffmann KR, Doi K, Fencil LE. Determination of instantaneous and average blood flow rates from digital angiograms of vessel phantoms using distance-density curves. Invest Radiol 1991; 26:207-212.
    • (1991) Invest Radiol , vol.26 , pp. 207-212
    • Hoffmann, K.R.1    Doi, K.2    Fencil, L.E.3
  • 14
    • 1642298642 scopus 로고    scopus 로고
    • Difference in flow characteristics between contrast media and blood during x-ray angiography
    • Wang Z, Kyprianou I, Rudin S, et al. Difference in flow characteristics between contrast media and blood during x-ray angiography (abstr). Med Phys 2002; 29: 1354.
    • (2002) Med Phys , vol.29 , pp. 1354
    • Wang, Z.1    Kyprianou, I.2    Rudin, S.3
  • 15
    • 1642388149 scopus 로고    scopus 로고
    • Evaluation of the effect of iodinated contrast media pooling on quantifying cerebral aneurysmal blood flow using x-ray angiograms
    • Wang Z, Kyprianou I, Rudin S, Wu Y, Bednarek DR, Hoffmann KR. Evaluation of the effect of iodinated contrast media pooling on quantifying cerebral aneurysmal blood flow using x-ray angiograms (abstr). Med Phys 2003; 30:1462.
    • (2003) Med Phys , vol.30 , pp. 1462
    • Wang, Z.1    Kyprianou, I.2    Rudin, S.3    Wu, Y.4    Bednarek, D.R.5    Hoffmann, K.R.6
  • 16
    • 0035052532 scopus 로고    scopus 로고
    • Analysis of slipstream flow in a wide-necked basilar artery aneurysm: Evaluation of potential treatment regimens
    • Imbesi SG, Kerber CW. Analysis of slipstream flow in a wide-necked basilar artery aneurysm: evaluation of potential treatment regimens. AJNR Am J Neuroradiol 2001; 22:721-724.
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 721-724
    • Imbesi, S.G.1    Kerber, C.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.