메뉴 건너뛰기




Volumn , Issue , 2007, Pages 579-584

Gait event detection with intelligent shoes

Author keywords

Gait event detection; Intelligent shoes; Support vector machine; Wearable robot

Indexed keywords

ARTIFICIAL INTELLIGENCE; CLASSIFICATION (OF INFORMATION); DATA REDUCTION; FINANCIAL DATA PROCESSING; IMAGE RETRIEVAL; LEARNING ALGORITHMS; LEARNING SYSTEMS; MERGERS AND ACQUISITIONS; SUPPORT VECTOR MACHINES; VECTORS;

EID: 47349115983     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICIA.2007.4295799     Document Type: Conference Paper
Times cited : (42)

References (10)
  • 1
    • 0034895669 scopus 로고    scopus 로고
    • Skelly, M.M. and Chizeck, H.J., Real-time gait event detection for paraplegic FES walking, Systems and Rehabilitation Engineering, IEEE Transactions on [see also IEEE Trans. on Rehabilitation Engineering] 9, Issue 1, March 2001
    • Skelly, M.M. and Chizeck, H.J., "Real-time gait event detection for paraplegic FES walking", Systems and Rehabilitation Engineering, IEEE Transactions on [see also IEEE Trans. on Rehabilitation Engineering] Volume 9, Issue 1, March 2001
  • 2
    • 0034283303 scopus 로고    scopus 로고
    • Williamson, R. and Andrews, B.J., Gait event detection for FES using accelerometers and supervised machine learning, Rehabilitation Engineering, IEEE Transactions on [see also IEEE Trans. on Neural Systems and Rehabilitation] 8, Issue 3, Sept. 2000
    • Williamson, R. and Andrews, B.J., "Gait event detection for FES using accelerometers and supervised machine learning", Rehabilitation Engineering, IEEE Transactions on [see also IEEE Trans. on Neural Systems and Rehabilitation] Volume 8, Issue 3, Sept. 2000
  • 4
    • 0031268842 scopus 로고    scopus 로고
    • Fuzzy model identification for classification of gait events in paraplegics, Fuzzy Syst
    • June
    • S. K. Ng and H. J. Chizeck, "Fuzzy model identification for classification of gait events in paraplegics", Fuzzy Syst., IEEE Transactions, Volume 5, pp. 536-544, June 1997
    • (1997) IEEE Transactions , vol.5 , pp. 536-544
    • Ng, S.K.1    Chizeck, H.J.2
  • 5
    • 0029066621 scopus 로고
    • Machine learning in control of function elcetrical stimulation systems for locomotion, Biomed. Eng
    • June
    • A. Kostov, B. J. Andrews, D. B. Popovic, R. B. Stein, and W. Armstrong, "Machine learning in control of function elcetrical stimulation systems for locomotion", Biomed. Eng., IEEE Transactions, Volume 42, pp. 541-551, June 1995
    • (1995) IEEE Transactions , vol.42 , pp. 541-551
    • Kostov, A.1    Andrews, B.J.2    Popovic, D.B.3    Stein, R.B.4    Armstrong, W.5
  • 6
    • 0008153126 scopus 로고
    • Significance of FES-assisted platarflexion during walking of incomplete SCI subjects
    • T. Bajd, A. Kralj, T. Karcnik, R. Savrin, and P. Obreza, "Significance of FES-assisted platarflexion during walking of incomplete SCI subjects", Gait Posture, Volume 2, pp. 5-10, 1990
    • (1990) Gait Posture , vol.2 , pp. 5-10
    • Bajd, T.1    Kralj, A.2    Karcnik, T.3    Savrin, R.4    Obreza, P.5
  • 7
    • 0028443327 scopus 로고
    • Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation, Rehab. Eng
    • June
    • R. Kobetic and E. B. Marsolais, "Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation", Rehab. Eng., IEEE Transactions, Volume 2, pp. 66-79, June 1994
    • (1994) IEEE Transactions , vol.2 , pp. 66-79
    • Kobetic, R.1    Marsolais, E.B.2
  • 8
    • 2342575621 scopus 로고    scopus 로고
    • A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
    • April
    • Ion P. I. Pappas, Thierry Keller, Sabine Mangold, Milos R. Popovic, Volker Dietz, and Manfred Morari, "A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole", IEEE Sensors Journal, Volume 4, pp. 268-274, April 2004
    • (2004) IEEE Sensors Journal , vol.4 , pp. 268-274
    • Pappas, I.P.I.1    Keller, T.2    Mangold, S.3    Popovic, M.R.4    Dietz, V.5    Morari, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.