메뉴 건너뛰기




Volumn 11, Issue SUPPL. 2, 2004, Pages

Endografting of the aortic arch

Author keywords

Aortic arch; Aortic dissection; Complications; Endograft design; Endoleak; Endovascular repair; Landing zone map; Migration; Stentgraft; Thoracic aorta; Thoracic aortic aneurysm

Indexed keywords

AORTA ANEURYSM; AORTA ARCH; AORTA INJURY; AORTA WALL; CORONARY STENT; DEVICE; ENDOLEAK; ENDOVASCULAR SURGERY; HUMAN; MEDICAL LITERATURE; PRIORITY JOURNAL; REVIEW; TECHNIQUE; THORACIC AORTA; THREE DIMENSIONAL IMAGING;

EID: 12144276913     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/04-1407.1     Document Type: Review
Times cited : (257)

References (46)
  • 1
    • 0031968175 scopus 로고    scopus 로고
    • Predictive factors for rupture of thoracoabdominal aortic aneurysm
    • Lobato AC, Puech-Leao P. Predictive factors for rupture of thoracoabdominal aortic aneurysm. J Vasc Surg. 1998;27:446-453.
    • (1998) J Vasc Surg , vol.27 , pp. 446-453
    • Lobato, A.C.1    Puech-Leao, P.2
  • 2
    • 0031727010 scopus 로고    scopus 로고
    • Thoracic and thoracoabdominal aneurysm repair using cardiopulmonary bypass, profound hypothermia, and circulatory arrest via left side of the chest incision
    • Safi HJ, Miller CC, Subramaniam MH, et al. Thoracic and thoracoabdominal aneurysm repair using cardiopulmonary bypass, profound hypothermia, and circulatory arrest via left side of the chest incision. J Vasc Surg. 1998;28:591-598.
    • (1998) J Vasc Surg , vol.28 , pp. 591-598
    • Safi, H.J.1    Miller, C.C.2    Subramaniam, M.H.3
  • 3
    • 0033382374 scopus 로고    scopus 로고
    • Self-expanding endovascular stent-graft implant for treatment of descending aortic diseases
    • Stolf NA, Pego Fernandes PM, Souza LR, et al. Self-expanding endovascular stent-graft implant for treatment of descending aortic diseases. J Card Surg. 1999;14:9-15.
    • (1999) J Card Surg , vol.14 , pp. 9-15
    • Stolf, N.A.1    Pego Fernandes, P.M.2    Souza, L.R.3
  • 4
    • 0033586995 scopus 로고    scopus 로고
    • Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement
    • Nienaber CA, Fattori R, Lund G, et al. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med. 1999;340:1539-1545.
    • (1999) N Engl J Med , vol.340 , pp. 1539-1545
    • Nienaber, C.A.1    Fattori, R.2    Lund, G.3
  • 5
    • 0020640806 scopus 로고
    • Transluminal expandable nitinol coil stent grafting: Preliminary report
    • Dotter CT, Buschmann RW, McKinney MK, et al. Transluminal expandable nitinol coil stent grafting: preliminary report. Radiology. 1983;147:259-260.
    • (1983) Radiology , vol.147 , pp. 259-260
    • Dotter, C.T.1    Buschmann, R.W.2    McKinney, M.K.3
  • 6
    • 0020522860 scopus 로고
    • Nonsurgical placement of arterial endoprostheses: A new technique using nitinol wire
    • Cragg A, Lund G, Rysavy J, et al. Nonsurgical placement of arterial endoprostheses: a new technique using nitinol wire. Radiology. 1983;147:261-263.
    • (1983) Radiology , vol.147 , pp. 261-263
    • Cragg, A.1    Lund, G.2    Rysavy, J.3
  • 7
    • 0022580654 scopus 로고
    • Transluminal placement of intraluminal polyurethane prosthesis for abdominal aortic aneurysm
    • Balko A, Piasecki GJ, Shah DM, et al. Transluminal placement of intraluminal polyurethane prosthesis for abdominal aortic aneurysm. J Surg Res. 1986;40:305-309.
    • (1986) J Surg Res , vol.40 , pp. 305-309
    • Balko, A.1    Piasecki, G.J.2    Shah, D.M.3
  • 8
    • 0024119126 scopus 로고
    • A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm
    • Volodos NL, Karpovich IP, Shekhanin VE, et al. A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm [in Russian]. Grudn Khir. 1988;6:84-86.
    • (1988) Grudn Khir , vol.6 , pp. 84-86
    • Volodos, N.L.1    Karpovich, I.P.2    Shekhanin, V.E.3
  • 9
    • 0026267990 scopus 로고
    • Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction
    • Volodos NL, Karpovich IP, Troyan VI, et al. Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. Vasa Suppl. 1991;33:93-95.
    • (1991) Vasa Suppl , vol.33 , pp. 93-95
    • Volodos, N.L.1    Karpovich, I.P.2    Troyan, V.I.3
  • 10
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg. 1991;5:491-499.
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 11
    • 0028631110 scopus 로고
    • Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms
    • Dake MD, Miller DC, Semba CP, et al. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med. 1994;331:1729-1734.
    • (1994) N Engl J Med , vol.331 , pp. 1729-1734
    • Dake, M.D.1    Miller, D.C.2    Semba, C.P.3
  • 12
    • 0029865278 scopus 로고    scopus 로고
    • Endovascular stent-graft repair of thoracic aortic aneurysms
    • Mitchell RS, Dake MD, Semba CP, et al. Endovascular stent-graft repair of thoracic aortic aneurysms. J Thorac Cardiovasc Surg. 1996;111:1054-1062.
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 1054-1062
    • Mitchell, R.S.1    Dake, M.D.2    Semba, C.P.3
  • 13
    • 0027321054 scopus 로고
    • Intravascular stenting of acute experimental type B dissections
    • Moon MR, Dake MD, Pelc LR, et al. Intravascular stenting of acute experimental type B dissections. J Surg Res. 1993;54:381-388.
    • (1993) J Surg Res , vol.54 , pp. 381-388
    • Moon, M.R.1    Dake, M.D.2    Pelc, L.R.3
  • 14
    • 0033586990 scopus 로고    scopus 로고
    • Endovascular stent-graft placement for the treatment of acute aortic dissection
    • Dake MD, Kato N, Mitchell RS, et al. Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med. 1999;340:1546-1552.
    • (1999) N Engl J Med , vol.340 , pp. 1546-1552
    • Dake, M.D.1    Kato, N.2    Mitchell, R.S.3
  • 15
    • 0031045662 scopus 로고    scopus 로고
    • Clinical application of transluminal endovascular graft placement for aortic aneurysm
    • Inoue K, Sato M, Tamaki S, et al. Clinical application of transluminal endovascular graft placement for aortic aneurysm. Ann Thorac Surg. 1997;63:522-528.
    • (1997) Ann Thorac Surg , vol.63 , pp. 522-528
    • Inoue, K.1    Sato, M.2    Tamaki, S.3
  • 16
    • 0036674056 scopus 로고    scopus 로고
    • Midterm results of stent-graft repair of acute and chronic aortic dissection with descending tear: The complication-specific approach
    • Kato N, Shimono T, Hirano T, et al. Midterm results of stent-graft repair of acute and chronic aortic dissection with descending tear: the complication-specific approach. J Thorac Cardiovasc Surg. 2002;124:306-312.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 306-312
    • Kato, N.1    Shimono, T.2    Hirano, T.3
  • 17
    • 0031979746 scopus 로고    scopus 로고
    • Preliminary report on prediction of spinal cord ischemia in endovascular stent-graft repair of thoracic aortic aneurysm by retrievable stent graft
    • Ishimaru S, Kawaguchi S, Koizumi N, et al. Preliminary report on prediction of spinal cord ischemia in endovascular stent-graft repair of thoracic aortic aneurysm by retrievable stent graft. J Thorac Cardiovasc Surg. 1998;115:811-818.
    • (1998) J Thorac Cardiovasc Surg , vol.115 , pp. 811-818
    • Ishimaru, S.1    Kawaguchi, S.2    Koizumi, N.3
  • 18
    • 0002876134 scopus 로고    scopus 로고
    • Classification of endovascular procedures for treating thoracic aortic aneurysms
    • Jacobs MJ, Branchereau A, eds. Armonk, NY: Futura Publishing Company
    • Balm R, Reekers JA, Jacobs MJ. Classification of endovascular procedures for treating thoracic aortic aneurysms. In: Jacobs MJ, Branchereau A, eds. Surgical and Endovascular Treatment of Aortic Aneurysms. Armonk, NY: Futura Publishing Company; 2000:19-26.
    • (2000) Surgical and Endovascular Treatment of Aortic Aneurysms , pp. 19-26
    • Balm, R.1    Reekers, J.A.2    Jacobs, M.J.3
  • 19
    • 0013308916 scopus 로고    scopus 로고
    • First International Summit on Thoracic Aortic Endografting: Roundtable on thoracic aortic dissection as an indication for endografting
    • Mitchell RS, Ishimaru S, Ehrlich MP, et al. First International Summit on Thoracic Aortic Endografting: roundtable on thoracic aortic dissection as an indication for endografting. J Endovasc Ther. 2002;9(suppl II):II-98-II105.
    • (2002) J Endovasc Ther , vol.9 , Issue.2 SUPPL.
    • Mitchell, R.S.1    Ishimaru, S.2    Ehrlich, M.P.3
  • 20
    • 0032938176 scopus 로고    scopus 로고
    • Thoracic aortic aneurysm repair with an endovascular stent graft: The "first generation"
    • Mitchell RS, Miller DC, Dake MD, et al. Thoracic aortic aneurysm repair with an endovascular stent graft: the "first generation." Ann Thorac Surg. 1999;67:1971-1974.
    • (1999) Ann Thorac Surg , vol.67 , pp. 1971-1974
    • Mitchell, R.S.1    Miller, D.C.2    Dake, M.D.3
  • 21
    • 0033978433 scopus 로고    scopus 로고
    • Endovascular repair of descending thoracic aortic aneurysms: An early experience with intermediate-term follow-up
    • Greenberg RK, Resch T, Nyman U, et al. Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up. J Vasc Surg. 2000;31:147-156.
    • (2000) J Vasc Surg , vol.31 , pp. 147-156
    • Greenberg, R.K.1    Resch, T.2    Nyman, U.3
  • 22
    • 17144443595 scopus 로고    scopus 로고
    • Aortic arch reconstruction by transluminally placed endovascular branched stent graft
    • Inoue K, Hosokawa H, Iwase T, et al. Aortic arch reconstruction by transluminally placed endovascular branched stent graft. Circulation. 1999;100(Suppl 19):II316-II321.
    • (1999) Circulation , vol.100 , Issue.19 SUPPL.
    • Inoue, K.1    Hosokawa, H.2    Iwase, T.3
  • 23
    • 0033744060 scopus 로고    scopus 로고
    • Treatment of Stanford type B aortic dissection with stent-grafts: Preliminary results
    • Czermak BV, Waldenberger P, Fraedrich G, et al. Treatment of Stanford type B aortic dissection with stent-grafts: preliminary results. Radiology. 2000;217:544-550.
    • (2000) Radiology , vol.217 , pp. 544-550
    • Czermak, B.V.1    Waldenberger, P.2    Fraedrich, G.3
  • 24
    • 0036154476 scopus 로고    scopus 로고
    • Endovascular stent-grafting for descending thoracic aortic aneurysms
    • Heijmen RH, Deblier IG, Moll FL, et al. Endovascular stent-grafting for descending thoracic aortic aneurysms. Eur J Cardiothorac Surg. 2002;21:5-9.
    • (2002) Eur J Cardiothorac Surg , vol.21 , pp. 5-9
    • Heijmen, R.H.1    Deblier, I.G.2    Moll, F.L.3
  • 25
    • 0036593014 scopus 로고    scopus 로고
    • Evolving experience with thoracic aortic stent graft repair
    • Cambria RP, Brewster DC, Lauterbach SR, et al. Evolving experience with thoracic aortic stent graft repair. J Vasc Surg. 2002;35:1129-1136.
    • (2002) J Vasc Surg , vol.35 , pp. 1129-1136
    • Cambria, R.P.1    Brewster, D.C.2    Lauterbach, S.R.3
  • 26
    • 0036185169 scopus 로고    scopus 로고
    • Endovascular repair of thoracic aortic aneurysms: Stent-graft fixation across the aortic arch vessels
    • Burks JA, Faries PL, Gravereaux EC, et al. Endovascular repair of thoracic aortic aneurysms: stent-graft fixation across the aortic arch vessels. Ann Vasc Surg. 2002;16:24-28.
    • (2002) Ann Vasc Surg , vol.16 , pp. 24-28
    • Burks, J.A.1    Faries, P.L.2    Gravereaux, E.C.3
  • 27
    • 0037001001 scopus 로고    scopus 로고
    • Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience
    • Criado FJ, Clark NS, Barnatan MF. Stent graft repair in the aortic arch and descending thoracic aorta: a 4-year experience. J Vasc Surg. 2002;36:1121-1128.
    • (2002) J Vasc Surg , vol.36 , pp. 1121-1128
    • Criado, F.J.1    Clark, N.S.2    Barnatan, M.F.3
  • 28
    • 19044366350 scopus 로고    scopus 로고
    • Endoluminal stent grafting of the thoracic aorta: Initial experience with the Gore Excluder
    • Thompson CS, Gaxotte VD, Rodriguez JA, et al. Endoluminal stent grafting of the thoracic aorta: initial experience with the Gore Excluder. J Vase Surg. 2002;35:1163-1170.
    • (2002) J Vase Surg , vol.35 , pp. 1163-1170
    • Thompson, C.S.1    Gaxotte, V.D.2    Rodriguez, J.A.3
  • 29
    • 0141741417 scopus 로고    scopus 로고
    • Descending thoracic aortic diseases: Stent-graft repair
    • Fattori R, Napoli G, Lovato L, et al. Descending thoracic aortic diseases: stent-graft repair. Radiology. 2003;229:176-183.
    • (2003) Radiology , vol.229 , pp. 176-183
    • Fattori, R.1    Napoli, G.2    Lovato, L.3
  • 30
    • 0037280262 scopus 로고    scopus 로고
    • Endovascular treatment in diseases of the descending thoracic aorta: 6-year results of a single center
    • Orend KH, Scharrer-Pamler R, Kapfer X, et al. Endovascular treatment in diseases of the descending thoracic aorta: 6-year results of a single center. J Vasc Surg. 2003;37:91-99.
    • (2003) J Vasc Surg , vol.37 , pp. 91-99
    • Orend, K.H.1    Scharrer-Pamler, R.2    Kapfer, X.3
  • 31
    • 0043056861 scopus 로고    scopus 로고
    • Endovascular aortic arch reconstruction with supra-aortic transposition for symptomatic contained rupture and dissection: Early experience in 8 high-risk patients
    • Schumacher H, Böckler D, Bardenheuer H, et al. Endovascular aortic arch reconstruction with supra-aortic transposition for symptomatic contained rupture and dissection: early experience in 8 high-risk patients. J Endovasc Ther. 2003;10:1066-1074.
    • (2003) J Endovasc Ther , vol.10 , pp. 1066-1074
    • Schumacher, H.1    Böckler, D.2    Bardenheuer, H.3
  • 32
    • 0037512317 scopus 로고    scopus 로고
    • Clinical application of a curved nitinol stent-graft for thoracic aortic aneurysms
    • Sanada J, Matsui O, Terayama N, et al. Clinical application of a curved nitinol stent-graft for thoracic aortic aneurysms. J Endovasc Ther. 2003;10:20-28.
    • (2003) J Endovasc Ther , vol.10 , pp. 20-28
    • Sanada, J.1    Matsui, O.2    Terayama, N.3
  • 33
    • 10744223716 scopus 로고    scopus 로고
    • Stent-graft placement in atherosclerotic descending thoracic aortic aneurysms: Midterm results
    • Czerny M, Cejna M, Hutschala D, et al. Stent-graft placement in atherosclerotic descending thoracic aortic aneurysms: midterm results. J Endovasc Ther. 2004;11:26-32.
    • (2004) J Endovasc Ther , vol.11 , pp. 26-32
    • Czerny, M.1    Cejna, M.2    Hutschala, D.3
  • 34
    • 0036616575 scopus 로고    scopus 로고
    • Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs
    • Görich J, Asquan Y, Seifarth H, et al. Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther. 2002;9(suppl II):II-39-II-43.
    • (2002) J Endovasc Ther , vol.9 , Issue.2 SUPPL.
    • Görich, J.1    Asquan, Y.2    Seifarth, H.3
  • 35
    • 0038335839 scopus 로고    scopus 로고
    • Endovascular stent graft placement in patients with acute thoracic aortic syndromes
    • Gräbenwoger M, Fleck T, Czerny M, et al. Endovascular stent graft placement in patients with acute thoracic aortic syndromes. Eur J Cardiothorac Surg. 2003;23:788-793.
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 788-793
    • Gräbenwoger, M.1    Fleck, T.2    Czerny, M.3
  • 36
    • 0029786213 scopus 로고    scopus 로고
    • Adenosine-induced transient cardiac asystole enhances precise deployment of stent-grafts in the thoracic or abdominal aorta
    • Dorros G, Cohn JM. Adenosine-induced transient cardiac asystole enhances precise deployment of stent-grafts in the thoracic or abdominal aorta. J Endovasc Surg. 1996;3:270-272.
    • (1996) J Endovasc Surg. , vol.3 , pp. 270-272
    • Dorros, G.1    Cohn, J.M.2
  • 37
    • 0031711791 scopus 로고    scopus 로고
    • Adenosine-induced transient cardiac arrest for placement of endovascular stent-grafts in the thoracic aorta
    • Weigand M, Motsch J, Bardenheuer HJ. Adenosine-induced transient cardiac arrest for placement of endovascular stent-grafts in the thoracic aorta. Anesthesiology. 1998;89:1037-1038.
    • (1998) Anesthesiology , vol.89 , pp. 1037-1038
    • Weigand, M.1    Motsch, J.2    Bardenheuer, H.J.3
  • 38
    • 16144367754 scopus 로고    scopus 로고
    • A safe, simple alternative for pressure reduction during aortic endograft deployment
    • Diethrich EB. A safe, simple alternative for pressure reduction during aortic endograft deployment [Commentary]. J Endovasc Surg. 1996;3:275.
    • (1996) J Endovasc Surg , vol.3 , pp. 275
    • Diethrich, E.B.1
  • 39
    • 0344643472 scopus 로고    scopus 로고
    • Endograft therapy for diseases of the descending thoracic aorta: Results in 43 high-risk patients
    • Lepore V, Lönn L, Delle M, et al. Endograft therapy for diseases of the descending thoracic aorta: results in 43 high-risk patients. J Endovasc Ther. 2002;9:829-837.
    • (2002) J Endovasc Ther , vol.9 , pp. 829-837
    • Lepore, V.1    Lönn, L.2    Delle, M.3
  • 40
    • 0031938737 scopus 로고    scopus 로고
    • Induction of ventricular fibrillation to facilitate endovascular stent graft repair of thoracic aortic aneurysms
    • Kahn RA, Marin ML, Hollier L, et al. Induction of ventricular fibrillation to facilitate endovascular stent graft repair of thoracic aortic aneurysms. Anesthesiology. 1998;88:534-536.
    • (1998) Anesthesiology , vol.88 , pp. 534-536
    • Kahn, R.A.1    Marin, M.L.2    Hollier, L.3
  • 41
    • 1842732236 scopus 로고    scopus 로고
    • Partial inflow occlusion facilitates accurate deployment of thoracic aortic endografts
    • Marty B, Chapuis Morales C, Tozzi P, et al. Partial inflow occlusion facilitates accurate deployment of thoracic aortic endografts. J Endovasc Ther. 2004;11:175-179.
    • (2004) J Endovasc Ther , vol.11 , pp. 175-179
    • Marty, B.1    Chapuis Morales, C.2    Tozzi, P.3
  • 42
    • 0034004007 scopus 로고    scopus 로고
    • Endovascular stent-graft deployment: Temporary vena caval occlusion with balloons to control aortic blood flow-experimental canine study and initial clinical experience
    • Ishiguchi T, Nishikimi N, Usui A, et al. Endovascular stent-graft deployment: temporary vena caval occlusion with balloons to control aortic blood flow-experimental canine study and initial clinical experience. Radiology. 2000;215:594-599.
    • (2000) Radiology , vol.215 , pp. 594-599
    • Ishiguchi, T.1    Nishikimi, N.2    Usui, A.3
  • 43
    • 10744231885 scopus 로고    scopus 로고
    • Challenges of endovascular tube graft repair of thoracic aortic aneurysm: Midterm follow-up and lessons learned
    • Ellozy SH, Carroccio A, Minor M, et al. Challenges of endovascular tube graft repair of thoracic aortic aneurysm: midterm follow-up and lessons learned. J Vasc Surg. 2003;38:676-683.
    • (2003) J Vasc Surg , vol.38 , pp. 676-683
    • Ellozy, S.H.1    Carroccio, A.2    Minor, M.3
  • 44
    • 0034761367 scopus 로고    scopus 로고
    • Emergency surgery for retrograde extension of type B dissection after endovascular stent graft repair
    • Totaro M, Miraldi F, andFanelli F, et al. Emergency surgery for retrograde extension of type B dissection after endovascular stent graft repair. Eur J Cardiothorac Surg. 2001;20:1057-1058.
    • (2001) Eur J Cardiothorac Surg , vol.20 , pp. 1057-1058
    • Totaro, M.1    Miraldi, F.2    Andfanelli, F.3
  • 45
    • 0035347171 scopus 로고    scopus 로고
    • Endovascular exclusion of descending thoracic aortic aneurysms and chronic dissections: Initial clinical results with the AneuRx device
    • White RA, Donayre CE, Walot I, et al. Endovascular exclusion of descending thoracic aortic aneurysms and chronic dissections: initial clinical results with the AneuRx device. J Vasc Surg. 2001;33:927-934.
    • (2001) J Vasc Surg , vol.33 , pp. 927-934
    • White, R.A.1    Donayre, C.E.2    Walot, I.3
  • 46
    • 0141919793 scopus 로고    scopus 로고
    • Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection
    • Chuter TAM, Schneider DB, Reilly LM, et al. Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection. J Vasc Surg. 2003;38:859-863.
    • (2003) J Vasc Surg , vol.38 , pp. 859-863
    • Chuter, T.A.M.1    Schneider, D.B.2    Reilly, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.