메뉴 건너뛰기




Volumn 60, Issue 1, 2008, Pages 53-63

Modeling the effects of dispersion and pulsatility of blood flow in pulsed arterial spin labeling

Author keywords

ASL; Dispersion; Pulsatility; Pulsed arterial spin labeling

Indexed keywords

BLOOD; DISPERSION (WAVES); DISPERSIONS; MAGNETIC RESONANCE IMAGING; UNCERTAINTY ANALYSIS;

EID: 46849119040     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21654     Document Type: Article
Times cited : (38)

References (21)
  • 3
    • 0028014523 scopus 로고
    • Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water
    • Roberts DA, Detre JA, Bolinger L, Insko EK, Leigh JSJ. Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water. Proc Natl Acad Sci USA 1994;91:33-37.
    • (1994) Proc Natl Acad Sci USA , vol.91 , pp. 33-37
    • Roberts, D.A.1    Detre, J.A.2    Bolinger, L.3    Insko, E.K.4    Leigh, J.S.J.5
  • 5
    • 12444321558 scopus 로고    scopus 로고
    • Interaction between secondary velocities, flow pulsation and vessel morphology in the common carotid artery
    • Tortoli P, Michelassi V, Bambi G, Guidi F, Righi D. Interaction between secondary velocities, flow pulsation and vessel morphology in the common carotid artery. Ultrasound Med Biol 2003;29:407-415.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 407-415
    • Tortoli, P.1    Michelassi, V.2    Bambi, G.3    Guidi, F.4    Righi, D.5
  • 6
    • 33846224253 scopus 로고    scopus 로고
    • The effects of flow dispersion and cardiac pulsation in arterial spin labeling
    • Wu WC, Mazaheri Y, Wong EC. The effects of flow dispersion and cardiac pulsation in arterial spin labeling. IEEE Trans Med Imaging 2007;26:84-92.
    • (2007) IEEE Trans Med Imaging , vol.26 , pp. 84-92
    • Wu, W.C.1    Mazaheri, Y.2    Wong, E.C.3
  • 7
    • 1242287516 scopus 로고    scopus 로고
    • Two analytical solutions for a model of pulsed arterial spin labeling with randomized blood arrival times
    • Hrabe J, Lewis DP. Two analytical solutions for a model of pulsed arterial spin labeling with randomized blood arrival times. J Magn Reson 2004;167:49-55.
    • (2004) J Magn Reson , vol.167 , pp. 49-55
    • Hrabe, J.1    Lewis, D.P.2
  • 8
    • 0042739012 scopus 로고    scopus 로고
    • Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
    • Calamante F, Yim PJ, Cebral JR. Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics. Neuroimage 2003;19(2 Pt 1):341-353.
    • (2003) Neuroimage , vol.19 , Issue.2 PART 1 , pp. 341-353
    • Calamante, F.1    Yim, P.J.2    Cebral, J.R.3
  • 9
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
    • Wong EC, Buxton RB, Frank LR. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magn Reson Med 1998;39:702-708.
    • (1998) Magn Reson Med , vol.39 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 10
    • 20044391646 scopus 로고    scopus 로고
    • Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries
    • Ford MD, Alperin N, Lee SH, Holdsworth DW, Steinman DA. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas 2005;26:477-488.
    • (2005) Physiol Meas , vol.26 , pp. 477-488
    • Ford, M.D.1    Alperin, N.2    Lee, S.H.3    Holdsworth, D.W.4    Steinman, D.A.5
  • 11
    • 0032997648 scopus 로고    scopus 로고
    • QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
    • Luh WM, Wong EC, Bandettini PA, Hyde JS. QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn Reson Med 1999;41:1246-1254.
    • (1999) Magn Reson Med , vol.41 , pp. 1246-1254
    • Luh, W.M.1    Wong, E.C.2    Bandettini, P.A.3    Hyde, J.S.4
  • 12
    • 0031022848 scopus 로고    scopus 로고
    • Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
    • Ye FQ, Mattay VS, Jezzard P, Frank JA, Weinberger DR, McLaughlin AC. Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magn Reson Med 1997;37:226-235.
    • (1997) Magn Reson Med , vol.37 , pp. 226-235
    • Ye, F.Q.1    Mattay, V.S.2    Jezzard, P.3    Frank, J.A.4    Weinberger, D.R.5    McLaughlin, A.C.6
  • 13
  • 14
    • 0032749944 scopus 로고    scopus 로고
    • Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: Comparison with hyperbolic secant
    • Yongbi MN, Yang Y, Frank JA, Duyn JH. Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant. Magn Reson Med 1999;42:1098-1105.
    • (1999) Magn Reson Med , vol.42 , pp. 1098-1105
    • Yongbi, M.N.1    Yang, Y.2    Frank, J.A.3    Duyn, J.H.4
  • 15
    • 46849098267 scopus 로고    scopus 로고
    • Comparison of ASL kinetic curves between subjects and between brain areas
    • Gallichan D, Jezzard P. Comparison of ASL kinetic curves between subjects and between brain areas. In: Proc ISMRM 2006:3432.
    • (2006) Proc ISMRM , pp. 3432
    • Gallichan, D.1    Jezzard, P.2
  • 16
    • 20044386904 scopus 로고    scopus 로고
    • Quantitative perfusion measurements using pulsed arterial spin labeling: Effects of large region-of-interest analysis
    • Figueiredo PM, Clare S, Jezzard P. Quantitative perfusion measurements using pulsed arterial spin labeling: effects of large region-of-interest analysis. J Magn Reson Imaging 2005;21:676-682.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 676-682
    • Figueiredo, P.M.1    Clare, S.2    Jezzard, P.3
  • 17
    • 0035091066 scopus 로고    scopus 로고
    • Rapid T(1) mapping using multislice echo planar imaging
    • Clare S, Jezzard P. Rapid T(1) mapping using multislice echo planar imaging. Magn Reson Med 2001;45:630-634.
    • (2001) Magn Reson Med , vol.45 , pp. 630-634
    • Clare, S.1    Jezzard, P.2
  • 18
    • 0345167988 scopus 로고    scopus 로고
    • Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla
    • Ethofer T, Mader I, Seeger U, Helms G, Erb M, Grodd W, Ludolph A, Klose U. Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla. Magn Reson Med 2003;50:1296-1301.
    • (2003) Magn Reson Med , vol.50 , pp. 1296-1301
    • Ethofer, T.1    Mader, I.2    Seeger, U.3    Helms, G.4    Erb, M.5    Grodd, W.6    Ludolph, A.7    Klose, U.8
  • 19
    • 0033817185 scopus 로고    scopus 로고
    • Effect of restricted water exchange on cerebral blood flow values calculated with arterial spin tagging: A theoretical investigation
    • St. Lawrence KS, Frank JA, McLaughlin AC. Effect of restricted water exchange on cerebral blood flow values calculated with arterial spin tagging: a theoretical investigation. Magn Reson Med 2000;44:440-449.
    • (2000) Magn Reson Med , vol.44 , pp. 440-449
    • St. Lawrence, K.S.1    Frank, J.A.2    McLaughlin, A.C.3
  • 20
    • 32544441071 scopus 로고    scopus 로고
    • Model-free arterial spin labeling quantification approach for perfusion MRI
    • Petersen ET, Lim T, Golay X. Model-free arterial spin labeling quantification approach for perfusion MRI. Magn Reson Med 2006;55:219-232.
    • (2006) Magn Reson Med , vol.55 , pp. 219-232
    • Petersen, E.T.1    Lim, T.2    Golay, X.3
  • 21
    • 46849105336 scopus 로고    scopus 로고
    • Early experience with new arterial spin labeling techniques in the assessment of acute stroke
    • Guenther M, Kern R, Szabo K, Griebe M, Hennerici M, Gass A. Early experience with new arterial spin labeling techniques in the assessment of acute stroke. In: Proc ISMRM 2005;13:1112.
    • (2005) Proc ISMRM , vol.13 , pp. 1112
    • Guenther, M.1    Kern, R.2    Szabo, K.3    Griebe, M.4    Hennerici, M.5    Gass, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.