메뉴 건너뛰기




Volumn 42, Issue 6, 1999, Pages 1098-1105

Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: Comparison with hyperbolic secant

Author keywords

FAIR; FOCI; Hyperbolic secant; Perfusion

Indexed keywords

BRAIN; FREQUENCY ALLOCATION; TISSUE;

EID: 0032749944     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199912)42:6<1098::AID-MRM14>3.0.CO;2-1     Document Type: Article
Times cited : (59)

References (24)
  • 2
  • 3
    • 0026877346 scopus 로고
    • Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: Accounting for transit times and cross-relaxation
    • Zhang D, Williams DS, Detre JA, Koretsky AP. Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: accounting for transit times and cross-relaxation. Magn Reson Med 1992;25:362-371.
    • (1992) Magn Reson Med , vol.25 , pp. 362-371
    • Zhang, D.1    Williams, D.S.2    Detre, J.A.3    Koretsky, A.P.4
  • 4
    • 0028014523 scopus 로고
    • Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water
    • Roberts DA, Detre JA, Bolinger L, Insko EK, Leigh JS. Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water. Proc Natl Acad Sci USA 1994;91:33-37.
    • (1994) Proc Natl Acad Sci USA , vol.91 , pp. 33-37
    • Roberts, D.A.1    Detre, J.A.2    Bolinger, L.3    Insko, E.K.4    Leigh, J.S.5
  • 5
    • 0028961859 scopus 로고
    • NMR measurement of perfusion using arterial spin-labelling without saturation of macromolecules spins
    • Zhang W, Silva A, Williams D, Koretsky A. NMR measurement of perfusion using arterial spin-labelling without saturation of macromolecules spins. Magn Reson Med 1995;33:370-376.
    • (1995) Magn Reson Med , vol.33 , pp. 370-376
    • Zhang, W.1    Silva, A.2    Williams, D.3    Koretsky, A.4
  • 6
    • 0030203923 scopus 로고    scopus 로고
    • Perfusion imaging of the human brain at 1.5 T using a single-short EPI spin tagging approach
    • Ye FQ, Pekar JJ, Jezzard P, Duyn J, Frank JA, McLaughlin AC. Perfusion imaging of the human brain at 1.5 T using a single-short EPI spin tagging approach. Magn Reson Med 1996;36:219-224.
    • (1996) Magn Reson Med , vol.36 , pp. 219-224
    • Ye, F.Q.1    Pekar, J.J.2    Jezzard, P.3    Duyn, J.4    Frank, J.A.5    McLaughlin, A.C.6
  • 7
    • 0027936294 scopus 로고
    • Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency
    • Edelman RR, Siewert B, Darby BG, Thangaraj V, Nobre AC, Mesulam MM, Warach S. Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency. Radiology 1994;192:513-520.
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, B.G.3    Thangaraj, V.4    Nobre, A.C.5    Mesulam, M.M.6    Warach, S.7
  • 9
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim S-G. Quantification of relative cerebral blood flow change by flow sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995;34:293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.-G.1
  • 10
    • 0030012099 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice
    • Schwarzbauer C, Morrisey S, Haase A. Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice. Magn Reson Med 1996;35:540-546.
    • (1996) Magn Reson Med , vol.35 , pp. 540-546
    • Schwarzbauer, C.1    Morrisey, S.2    Haase, A.3
  • 11
    • 0031019253 scopus 로고    scopus 로고
    • Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging
    • Kim S-G, Tsekos NV. Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: application to functional brain imaging. Magn Reson Med 1997;37:425-435.
    • (1997) Magn Reson Med , vol.37 , pp. 425-435
    • Kim, S.-G.1    Tsekos, N.V.2
  • 12
    • 0030940606 scopus 로고    scopus 로고
    • Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR)
    • Helpern JA, Branch CA, Yongbi MN, Huang NC. Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR). Magn Reson Imaging 1997;15:135-139.
    • (1997) Magn Reson Imaging , vol.15 , pp. 135-139
    • Helpern, J.A.1    Branch, C.A.2    Yongbi, M.N.3    Huang, N.C.4
  • 14
    • 0031966050 scopus 로고    scopus 로고
    • Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPPS II)
    • Wong EC, Buxton RB, Frank LR. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPPS II). Magn Reson Med 1998;39:702-708.
    • (1998) Magn Reson Med , vol.39 , pp. 702-708
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 15
    • 0031956255 scopus 로고    scopus 로고
    • Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
    • Yang Y, Frank JA, Hou L, Ye FQ, McLaughlin AC, Duyn JH. Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling. Magn Reson Med 1998;39:825-832.
    • (1998) Magn Reson Med , vol.39 , pp. 825-832
    • Yang, Y.1    Frank, J.A.2    Hou, L.3    Ye, F.Q.4    McLaughlin, A.C.5    Duyn, J.H.6
  • 16
    • 4243461379 scopus 로고
    • Selective spin inversion in nuclear magnetic resonance and coherence optics through an exact solution of the Bloch-Riccati equations
    • Silver MS, Joseph RI, Hoult DI. Selective spin inversion in nuclear magnetic resonance and coherence optics through an exact solution of the Bloch-Riccati equations. Phys Rev 1985;A31:2753-2755.
    • (1985) Phys Rev , vol.A31 , pp. 2753-2755
    • Silver, M.S.1    Joseph, R.I.2    Hoult, D.I.3
  • 18
    • 0344178986 scopus 로고    scopus 로고
    • FOCI pulses re-visited as re-mapped hyperbolic secant pulses tagging with the FOCI pulse
    • Philadelphia, PA
    • Matson FB. FOCI pulses re-visited as re-mapped hyperbolic secant pulses tagging with the FOCI pulse. In: Proceedings of the ISMRM 7th Scientific Meeting, Philadelphia, PA. 1999. p 2086.
    • (1999) Proceedings of the ISMRM 7th Scientific Meeting , pp. 2086
    • Matson, F.B.1
  • 20
    • 0030716493 scopus 로고    scopus 로고
    • Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system
    • Payne GS, Leach MO. Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system. Magn Reson Med 1997;38:828.
    • (1997) Magn Reson Med , vol.38 , pp. 828
    • Payne, G.S.1    Leach, M.O.2
  • 22
    • 0031848388 scopus 로고    scopus 로고
    • A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging
    • Wong EC, Buxton RB, Frank LR. A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging. Magn Reson Med 1998 40:348-355.
    • (1998) Magn Reson Med , vol.40 , pp. 348-355
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 24
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • Wong EC, Buxton RB, Frank LR. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed 1997;10:237-249.
    • (1997) NMR Biomed , vol.10 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.