메뉴 건너뛰기




Volumn 43, Issue 6, 2008, Pages 726-735

Analytical characterization of microfabricated SU-8 emitters for electrospray ionization mass spectrometry

Author keywords

Electrospray ionization; Mass spectrometry; Microchip technology; Microfluidics; SU 8 polymer

Indexed keywords

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; IONIZATION; MASS SPECTROMETERS; MASS SPECTROMETRY; MICROCHANNELS; OPTICAL DESIGN; OPTIMIZATION; SPECTROMETERS; SPECTROMETRY; SPECTRUM ANALYSIS;

EID: 46849114947     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.1368     Document Type: Article
Times cited : (17)

References (56)
  • 2
    • 33748168091 scopus 로고
    • Formation energies and concentrations of microclusters for homogeneous nucleation
    • Yamashita M, Fenn JB. Formation energies and concentrations of microclusters for homogeneous nucleation. Journal of Chemical Physics 1984; 88: 4451.
    • (1984) Journal of Chemical Physics , vol.88 , pp. 4451
    • Yamashita, M.1    Fenn, J.B.2
  • 5
    • 0029685702 scopus 로고    scopus 로고
    • Analytical properties of the nanoelectrospray ion source
    • Wilm MS, Mann M. Analytical properties of the nanoelectrospray ion source. Analytical Chemistry 1996; 68: 1.
    • (1996) Analytical Chemistry , vol.68 , pp. 1
    • Wilm, M.S.1    Mann, M.2
  • 6
    • 0005036961 scopus 로고    scopus 로고
    • Generating electrospray from microchip devices using electroosmotic pumping
    • Ramsey RS, Ramsey JM. Generating electrospray from microchip devices using electroosmotic pumping. Analytical Chemistry 1997; 69: 1174.
    • (1997) Analytical Chemistry , vol.69 , pp. 1174
    • Ramsey, R.S.1    Ramsey, J.M.2
  • 9
    • 0035891197 scopus 로고    scopus 로고
    • Polymer microspray with an integrated thick-film microelectrode
    • Rohner TC, Rossier JS, Girault HH. Polymer microspray with an integrated thick-film microelectrode. Analytical Chemistry 2001; 73: 5353.
    • (2001) Analytical Chemistry , vol.73 , pp. 5353
    • Rohner, T.C.1    Rossier, J.S.2    Girault, H.H.3
  • 10
    • 4344684428 scopus 로고    scopus 로고
    • Efficient electrospray ionization from polymer microchannels using integrated hydrophobic membrane
    • Wang YX, Cooper JW, Lee CS, DeVoe DL. Efficient electrospray ionization from polymer microchannels using integrated hydrophobic membrane. Lab on a Chip 2004; 4: 363.
    • (2004) Lab on a Chip , vol.4 , pp. 363
    • Wang, Y.X.1    Cooper, J.W.2    Lee, C.S.3    DeVoe, D.L.4
  • 11
    • 33144456907 scopus 로고    scopus 로고
    • Fabrication of porous polymer monoliths in polymeric microfluidic chips as an electrospray emitter for direct coupling to mass spectrometry
    • Bedair MF, Oleschuk RD. Fabrication of porous polymer monoliths in polymeric microfluidic chips as an electrospray emitter for direct coupling to mass spectrometry. Analytical Chemistry 2006; 78: 1130.
    • (2006) Analytical Chemistry , vol.78 , pp. 1130
    • Bedair, M.F.1    Oleschuk, R.D.2
  • 12
    • 0345873262 scopus 로고    scopus 로고
    • Microfluidic device for capillary electrochromatography-mass spectrometry
    • Lazar IM, Li L, Yang Y, Karger BL. Microfluidic device for capillary electrochromatography-mass spectrometry. Electrophoresis 2003; 24: 3655.
    • (2003) Electrophoresis , vol.24 , pp. 3655
    • Lazar, I.M.1    Li, L.2    Yang, Y.3    Karger, B.L.4
  • 13
    • 0032809717 scopus 로고    scopus 로고
    • Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry
    • Zhang B, Liu H, Karger BL, Foret F. Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry. Analytical Chemistry 1999; 71: 3258.
    • (1999) Analytical Chemistry , vol.71 , pp. 3258
    • Zhang, B.1    Liu, H.2    Karger, B.L.3    Foret, F.4
  • 14
    • 0031206748 scopus 로고    scopus 로고
    • A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry
    • Figeys D, Ning Y, Aebersold R. A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry. Analytical Chemistry 1997; 69: 3153.
    • (1997) Analytical Chemistry , vol.69 , pp. 3153
    • Figeys, D.1    Ning, Y.2    Aebersold, R.3
  • 15
    • 0032732346 scopus 로고    scopus 로고
    • Microfabricated polymer devices for automated sample delivery of peptides for analysis by electrospray ionization tandem mass spectrometry
    • Chan JH, Timperman AT, Qin D, Aebersold R. Microfabricated polymer devices for automated sample delivery of peptides for analysis by electrospray ionization tandem mass spectrometry. Analytical Chemistry 1999; 71: 4437.
    • (1999) Analytical Chemistry , vol.71 , pp. 4437
    • Chan, J.H.1    Timperman, A.T.2    Qin, D.3    Aebersold, R.4
  • 16
    • 0032799817 scopus 로고    scopus 로고
    • Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: Application to rapid analyses of proteolytic digests
    • Li J, Thibault P, Bings NH, Skinner CD, Wang C, Colyer C, Harrison J. Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: application to rapid analyses of proteolytic digests. Analytical Chemistry 1999; 71: 3036.
    • (1999) Analytical Chemistry , vol.71 , pp. 3036
    • Li, J.1    Thibault, P.2    Bings, N.H.3    Skinner, C.D.4    Wang, C.5    Colyer, C.6    Harrison, J.7
  • 18
    • 0035866596 scopus 로고    scopus 로고
    • Interfacing a polymer-based micromachined device to a nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometer
    • Meng Z, Qi S, Soper SA, Limbach PA. Interfacing a polymer-based micromachined device to a nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometer. Analytical Chemistry 2001; 73: 1286.
    • (2001) Analytical Chemistry , vol.73 , pp. 1286
    • Meng, Z.1    Qi, S.2    Soper, S.A.3    Limbach, P.A.4
  • 20
    • 0033198571 scopus 로고    scopus 로고
    • Subattomole-sensitivity microchip nanoelectrospray source with time-of-flight mass spectrometry detection
    • Lazar IM, Ramsey RS, Sundberg S, Ramsey M. Subattomole-sensitivity microchip nanoelectrospray source with time-of-flight mass spectrometry detection. Analytical Chemistry 1999; 71: 3627.
    • (1999) Analytical Chemistry , vol.71 , pp. 3627
    • Lazar, I.M.1    Ramsey, R.S.2    Sundberg, S.3    Ramsey, M.4
  • 21
    • 0035326230 scopus 로고    scopus 로고
    • Integrated plastic microfluidic devices with ESI-MS for drug screening and residue analysis
    • Jiang Y, Wang PC, Locascio LE, Lee CS. Integrated plastic microfluidic devices with ESI-MS for drug screening and residue analysis. Analytical Chemistry 2001; 73: 2048.
    • (2001) Analytical Chemistry , vol.73 , pp. 2048
    • Jiang, Y.1    Wang, P.C.2    Locascio, L.E.3    Lee, C.S.4
  • 22
    • 0035253647 scopus 로고    scopus 로고
    • Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine
    • Deng Y, Henion J, Li J, Thibault P, Wang C, Harrison J. Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine. Analytical Chemistry 2001; 73: 639.
    • (2001) Analytical Chemistry , vol.73 , pp. 639
    • Deng, Y.1    Henion, J.2    Li, J.3    Thibault, P.4    Wang, C.5    Harrison, J.6
  • 23
    • 0037144250 scopus 로고    scopus 로고
    • Micro devices integrated with microchannels and electrospray nozzles using PDMS casting techniques
    • Chiou CH, Lee GB, Hsu HT, Chen PW, Liao PC. Micro devices integrated with microchannels and electrospray nozzles using PDMS casting techniques. Sensors and Actuators B 2002; 86: 280.
    • (2002) Sensors and Actuators B , vol.86 , pp. 280
    • Chiou, C.H.1    Lee, G.B.2    Hsu, H.T.3    Chen, P.W.4    Liao, P.C.5
  • 24
    • 0035326424 scopus 로고    scopus 로고
    • A polymeric microfluidic chip for CE/MS determination of small molecules
    • Kameoka J, Craighead HG, Zhang H, Henion J. A polymeric microfluidic chip for CE/MS determination of small molecules. Analytical Chemistry 2001; 73: 1935.
    • (2001) Analytical Chemistry , vol.73 , pp. 1935
    • Kameoka, J.1    Craighead, H.G.2    Zhang, H.3    Henion, J.4
  • 27
    • 34249005915 scopus 로고    scopus 로고
    • Microfabricated monolithic multinozzle emitters for nanoelectrospray mass spectrometry
    • Kim W, Guo M, Yang P, Wang D. Microfabricated monolithic multinozzle emitters for nanoelectrospray mass spectrometry. Analytical Chemistry 2007; 79: 3703.
    • (2007) Analytical Chemistry , vol.79 , pp. 3703
    • Kim, W.1    Guo, M.2    Yang, P.3    Wang, D.4
  • 29
    • 0034282498 scopus 로고    scopus 로고
    • A fully integrated monolithic microchip electrospray device for mass spectrometry
    • Schultz GA, Corso TN, Prosser SJ, Zhang S. A fully integrated monolithic microchip electrospray device for mass spectrometry. Analytical Chemistry 2000; 72: 4058.
    • (2000) Analytical Chemistry , vol.72 , pp. 4058
    • Schultz, G.A.1    Corso, T.N.2    Prosser, S.J.3    Zhang, S.4
  • 31
    • 34447333124 scopus 로고    scopus 로고
    • Microfluidic glass chips with an integrated nanospray emitter for coupling to a mass spectrometer
    • Hoffmann P, Häusig U, Schulze P, Belder D. Microfluidic glass chips with an integrated nanospray emitter for coupling to a mass spectrometer. Angewandte Chemie International Edition 2007; 46: 4913.
    • (2007) Angewandte Chemie International Edition , vol.46 , pp. 4913
    • Hoffmann, P.1    Häusig, U.2    Schulze, P.3    Belder, D.4
  • 32
    • 0035958612 scopus 로고    scopus 로고
    • Microfabrication of polydimethylsiloxane electrospray ionization emitters
    • Kim JS, Knapp DR. Microfabrication of polydimethylsiloxane electrospray ionization emitters. Journal of Chromatography A 2001; 924: 137.
    • (2001) Journal of Chromatography A , vol.924 , pp. 137
    • Kim, J.S.1    Knapp, D.R.2
  • 33
    • 4344713523 scopus 로고    scopus 로고
    • Poly(dimethylsiloxane) microchip: Microchannel with integrated open electrospray tip
    • Svedberg M, Veszelei M, Axelsson J, Vangbo M, Nikolajeff F. Poly(dimethylsiloxane) microchip: microchannel with integrated open electrospray tip. Lab on a Chip 2004; 4: 322.
    • (2004) Lab on a Chip , vol.4 , pp. 322
    • Svedberg, M.1    Veszelei, M.2    Axelsson, J.3    Vangbo, M.4    Nikolajeff, F.5
  • 34
    • 14044265644 scopus 로고    scopus 로고
    • Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip
    • Pettersson Dahlin A, Wetterfall M, Liljegren G, Bergström S, Andrén P, Nyholm L, Markides KE, Bergquist J. Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip. Analyst 2005; 130: 193.
    • (2005) Analyst , vol.130 , pp. 193
    • Pettersson Dahlin, A.1    Wetterfall, M.2    Liljegren, G.3    Bergström, S.4    Andrén, P.5    Nyholm, L.6    Markides, K.E.7    Bergquist, J.8
  • 35
    • 0035866638 scopus 로고    scopus 로고
    • Sequential electrospray analysis using sharp-tip channels fabricated on a plastic chip
    • Yuan CH, Shiea J. Sequential electrospray analysis using sharp-tip channels fabricated on a plastic chip. Analytical Chemistry 2001; 73: 1080.
    • (2001) Analytical Chemistry , vol.73 , pp. 1080
    • Yuan, C.H.1    Shiea, J.2
  • 37
    • 12244255362 scopus 로고    scopus 로고
    • Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip
    • Yin H, Killeen K, Brennen R, Sobek D, Werlich M, van der Goor T. Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip. Analytical Chemistry 2005; 77: 527.
    • (2005) Analytical Chemistry , vol.77 , pp. 527
    • Yin, H.1    Killeen, K.2    Brennen, R.3    Sobek, D.4    Werlich, M.5    van der Goor, T.6
  • 39
    • 27644561007 scopus 로고    scopus 로고
    • A new mass spectrometry electrospray tip obtained via precise mechanical micromachining
    • Chang YZ, Yang MW, Wang GJ. A new mass spectrometry electrospray tip obtained via precise mechanical micromachining. Analytical and Bioanalytical Chemistry 2005; 383: 76.
    • (2005) Analytical and Bioanalytical Chemistry , vol.383 , pp. 76
    • Chang, Y.Z.1    Yang, M.W.2    Wang, G.J.3
  • 42
    • 27544508864 scopus 로고    scopus 로고
    • Microfluidic platform for liquid chromatography-tandem mass spectrometry analyses of complex peptide mixtures
    • Xie J, Miao Y, Shih J, Tai YC, Lee TD. Microfluidic platform for liquid chromatography-tandem mass spectrometry analyses of complex peptide mixtures. Analytical Chemistry 2005; 77: 6947.
    • (2005) Analytical Chemistry , vol.77 , pp. 6947
    • Xie, J.1    Miao, Y.2    Shih, J.3    Tai, Y.C.4    Lee, T.D.5
  • 43
    • 17644389929 scopus 로고    scopus 로고
    • A polysilicon nanoelectrospray-mass spectrometry source based on a microfluidic capillary slot
    • Arscott S, LeGac S, Rolando C. A polysilicon nanoelectrospray-mass spectrometry source based on a microfluidic capillary slot. Sensors and Actuators B 2005; 106: 741.
    • (2005) Sensors and Actuators B , vol.106 , pp. 741
    • Arscott, S.1    LeGac, S.2    Rolando, C.3
  • 45
    • 29744435721 scopus 로고    scopus 로고
    • An open design microfabricated nib-like nanoelectrospray emitter tip on a conducting silicon substrate for the application of the ionization voltage
    • LeGac S, Rolando C, Arscott S. An open design microfabricated nib-like nanoelectrospray emitter tip on a conducting silicon substrate for the application of the ionization voltage. Journal of the American Society for Mass Spectrometry 2006; 17: 75.
    • (2006) Journal of the American Society for Mass Spectrometry , vol.17 , pp. 75
    • LeGac, S.1    Rolando, C.2    Arscott, S.3
  • 47
    • 17644392079 scopus 로고    scopus 로고
    • Free-standing SU-8 microfluidic chips by adhesive bonding and release etching
    • Tuomikoski S, Franssila S. Free-standing SU-8 microfluidic chips by adhesive bonding and release etching. Sensors and Actuators A 2005; 120: 408.
    • (2005) Sensors and Actuators A , vol.120 , pp. 408
    • Tuomikoski, S.1    Franssila, S.2
  • 52
    • 0035870192 scopus 로고    scopus 로고
    • Generation of multiple electrosprays using microfabricated emitter arrays for improved mass spectrometric sensitivity
    • Tang K, Lin Y, Matson DW, Kim T, Smith RD. Generation of multiple electrosprays using microfabricated emitter arrays for improved mass spectrometric sensitivity. Analytical Chemistry 2001; 73: 1658.
    • (2001) Analytical Chemistry , vol.73 , pp. 1658
    • Tang, K.1    Lin, Y.2    Matson, D.W.3    Kim, T.4    Smith, R.D.5
  • 53
    • 0035500076 scopus 로고    scopus 로고
    • Sheathless capillary electrophoresis/ electrospray mass spectrometry using a carbon-coated tapered fused-silica capillary with a beveled edge
    • Chang YZ, Chen YR, Her GR. Sheathless capillary electrophoresis/ electrospray mass spectrometry using a carbon-coated tapered fused-silica capillary with a beveled edge. Analytical Chemistry 2001; 73: 5083.
    • (2001) Analytical Chemistry , vol.73 , pp. 5083
    • Chang, Y.Z.1    Chen, Y.R.2    Her, G.R.3
  • 55
    • 27644481540 scopus 로고    scopus 로고
    • Rapid, accurate and precise quantitative drug analysis: Comparing liquid chromatography tandem mass spectrometry and chip-based nanoelectrospray ionisation mass spectrometry
    • Alfazema L, Richards D, Gélébart S, Mitchell J, Snowden M. Rapid, accurate and precise quantitative drug analysis: comparing liquid chromatography tandem mass spectrometry and chip-based nanoelectrospray ionisation mass spectrometry. European Journal of Mass Spectrometry 2005; 11: 393.
    • (2005) European Journal of Mass Spectrometry , vol.11 , pp. 393
    • Alfazema, L.1    Richards, D.2    Gélébart, S.3    Mitchell, J.4    Snowden, M.5
  • 56
    • 0037442314 scopus 로고    scopus 로고
    • Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry
    • Dethy JM, Ackermann BL, Delatour C, Henion JD, Schultz GA. Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry. Analytical Chemistry 2003; 75: 805.
    • (2003) Analytical Chemistry , vol.75 , pp. 805
    • Dethy, J.M.1    Ackermann, B.L.2    Delatour, C.3    Henion, J.D.4    Schultz, G.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.