Volumn 20, Issue 4, 2008, Pages 247-252

Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography

Author keywords

Double lumen endobronchial tube; Thoracic anesthesia; Ultrasonography

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DOUBLE LUMEN TUBE; ECHOGRAPHY; FEMALE; HUMAN; LUNG COLLAPSE; MALE; OBSERVATIONAL STUDY; PRIORITY JOURNAL; THORAX SURGERY; TRACHEA;

EID: 46449109401     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jclinane.2007.11.002     Document Type: Article
Times cited : (65)

References (19)
  • 1
    • 0037628935 scopus 로고    scopus 로고
    • Left double-lumen tubes: clinical experience with 1,170 patients
    • Brodsky J.B., and Lemmens H.J. Left double-lumen tubes: clinical experience with 1,170 patients. J Cardiothorac Vasc Anesth 17 (2003) 289-298
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 289-298
    • Brodsky, J.B.1    Lemmens, H.J.2
  • 2
    • 0036172257 scopus 로고    scopus 로고
    • Methods of lung separation
    • Cohen E. Methods of lung separation. Curr Opin Anaesthesiol 15 (2002) 69-78
    • (2002) Curr Opin Anaesthesiol , vol.15 , pp. 69-78
    • Cohen, E.1
  • 3
    • 0023449789 scopus 로고
    • Margin of safety in positioning modern double-lumen endotracheal tube
    • Benumof J.L., Partridge B.L., Salvatierra L., and Keating J. Margin of safety in positioning modern double-lumen endotracheal tube. Anesthesiology 67 (1987) 729-738
    • (1987) Anesthesiology , vol.67 , pp. 729-738
    • Benumof, J.L.1    Partridge, B.L.2    Salvatierra, L.3    Keating, J.4
  • 4
    • 25644443879 scopus 로고    scopus 로고
    • Tracheal perforation from double-lumen tubes: size may be important [Letter]
    • Lohser J., and Brodsky J.B. Tracheal perforation from double-lumen tubes: size may be important [Letter]. Anaesth Analg 101 (2005) 1243-1244
    • (2005) Anaesth Analg , vol.101 , pp. 1243-1244
    • Lohser, J.1    Brodsky, J.B.2
  • 5
    • 0029998807 scopus 로고    scopus 로고
    • Tracheal diameter predicts double-lumen tube size: a method for selecting left double-tubes
    • Brodsky J.B., Macario A., and Mark J.B. Tracheal diameter predicts double-lumen tube size: a method for selecting left double-tubes. Anesth Analg 82 (1996) 861-864
    • (1996) Anesth Analg , vol.82 , pp. 861-864
    • Brodsky, J.B.1    Macario, A.2    Mark, J.B.3
  • 6
    • 0035073646 scopus 로고    scopus 로고
    • The relationship between tracheal width and left bronchial width: implication for left-sided double-lumen tube selection
    • Brodsky J.B., Malott K., Angst M., Fitzmaurice B.G., Kee S.P., and Logan L. The relationship between tracheal width and left bronchial width: implication for left-sided double-lumen tube selection. J Cardiothorac Vasc Anesth 15 (2001) 216-217
    • (2001) J Cardiothorac Vasc Anesth , vol.15 , pp. 216-217
    • Brodsky, J.B.1    Malott, K.2    Angst, M.3    Fitzmaurice, B.G.4    Kee, S.P.5    Logan, L.6
  • 7
    • 20444388672 scopus 로고    scopus 로고
    • Tracheal width and left double-lumen tube size: a formula to estimate left-bronchial width
    • Brodsky J.B., and Lemmens H.J. Tracheal width and left double-lumen tube size: a formula to estimate left-bronchial width. J Clin Anesth 17 (2005) 267-270
    • (2005) J Clin Anesth , vol.17 , pp. 267-270
    • Brodsky, J.B.1    Lemmens, H.J.2
  • 8
    • 0031541871 scopus 로고    scopus 로고
    • Sonographic imaging of the trachea
    • Shih J.Y., Lee L.N., Wu H.D., et al. Sonographic imaging of the trachea. J Ultrasound Med 16 (1997) 783-790
    • (1997) J Ultrasound Med , vol.16 , pp. 783-790
    • Shih, J.Y.1    Lee, L.N.2    Wu, H.D.3
  • 9
    • 0036713946 scopus 로고    scopus 로고
    • Percutaneous dilatational tracheostomy versus surgical tracheostomy in patients with anterior cervical spine fixation: preliminary report
    • Šustić A., Krstulović B., Eškinja N., et al. Percutaneous dilatational tracheostomy versus surgical tracheostomy in patients with anterior cervical spine fixation: preliminary report. Spine 27 (2002) 1942-1945
    • (2002) Spine , vol.27 , pp. 1942-1945
    • Šustić, A.1    Krstulović, B.2    Eškinja, N.3
  • 11
    • 34247347848 scopus 로고    scopus 로고
    • Role of ultrasound in the airway management of critically ill patients
    • Šustić A. Role of ultrasound in the airway management of critically ill patients. Crit Care Med 35 5 Suppl (2007) S173-S177
    • (2007) Crit Care Med , vol.35 , Issue.5 SUPPL
    • Šustić, A.1
  • 12
    • 0027380039 scopus 로고
    • Comparison of three techniques to inflate the bronchial cuff of left polyvinyl chloride double-lumen tubes
    • Hannallah M.S., Benumof J.L., McCarthy P.O., and Liang M. Comparison of three techniques to inflate the bronchial cuff of left polyvinyl chloride double-lumen tubes. Anesth Analg 77 (1993) 990-994
    • (1993) Anesth Analg , vol.77 , pp. 990-994
    • Hannallah, M.S.1    Benumof, J.L.2    McCarthy, P.O.3    Liang, M.4
  • 13
    • 0031807844 scopus 로고    scopus 로고
    • Predicting the size of a double-lumen endobronchial tube based on tracheal diameter
    • Chow M.Y., Liam B.L., Lew T.W., Chelliah R.Y., and Ong B.C. Predicting the size of a double-lumen endobronchial tube based on tracheal diameter. Anesth Analg 87 (1998) 158-160
    • (1998) Anesth Analg , vol.87 , pp. 158-160
    • Chow, M.Y.1    Liam, B.L.2    Lew, T.W.3    Chelliah, R.Y.4    Ong, B.C.5
  • 14
    • 0032909192 scopus 로고    scopus 로고
    • Predicting the size of the double-lumen endotracheal tube using computed tomographic scan measurement of the left main bronchus diameter
    • Chow M.Y., Liam B.L., Thng C.H., and Chong B.K. Predicting the size of the double-lumen endotracheal tube using computed tomographic scan measurement of the left main bronchus diameter. Anesth Analg 88 (1999) 302-305
    • (1999) Anesth Analg , vol.88 , pp. 302-305
    • Chow, M.Y.1    Liam, B.L.2    Thng, C.H.3    Chong, B.K.4
  • 15
    • 0027424342 scopus 로고
    • The resting volume and compliance characteristics of the bronchial cuff of the left polyvinyl chloride double-lumen endobronchial tube
    • Hannallah M.S., Benumof J.L., Bachenheimer L.C., and Mundt D.J. The resting volume and compliance characteristics of the bronchial cuff of the left polyvinyl chloride double-lumen endobronchial tube. Anesth Analg 77 (1993) 1222-1226
    • (1993) Anesth Analg , vol.77 , pp. 1222-1226
    • Hannallah, M.S.1    Benumof, J.L.2    Bachenheimer, L.C.3    Mundt, D.J.4
  • 16
    • 0032871486 scopus 로고    scopus 로고
    • Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-tube size
    • Eberle B., Weiler N., Vogel N., Kauczor H.U., and Heinrichs W. Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-tube size. J Cardiothorac Vasc Anesth 13 (1999) 532-537
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 532-537
    • Eberle, B.1    Weiler, N.2    Vogel, N.3    Kauczor, H.U.4    Heinrichs, W.5
  • 17
    • 0031003952 scopus 로고    scopus 로고
    • Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter
    • Hannallah M., Benumof J.L., Silverman P.M., Kelly L.C., and Lea D. Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter. J Cardiothorac Vasc Anesth 11 (1997) 168-171
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 168-171
    • Hannallah, M.1    Benumof, J.L.2    Silverman, P.M.3    Kelly, L.C.4    Lea, D.5
  • 18
    • 33746376993 scopus 로고    scopus 로고
    • Measurement of left mainstem bronchus using multiplane CT reconstructions and relationship between patient characteristics or tracheal diameters and left bronchial diameters
    • Olivier P., Hayon-Sonsino D., Convard J.P., Laloë P.A., and Fischler M. Measurement of left mainstem bronchus using multiplane CT reconstructions and relationship between patient characteristics or tracheal diameters and left bronchial diameters. Chest 130 (2006) 101-107
    • (2006) Chest , vol.130 , pp. 101-107
    • Olivier, P.1    Hayon-Sonsino, D.2    Convard, J.P.3    Laloë, P.A.4    Fischler, M.5
  • 19
    • 0033665953 scopus 로고    scopus 로고
    • Positioning of a double-lumen endobronchal tube without the aid of any instruments: an implication for emergency management
    • Bahk J.H., Lim Y.J., and Kim C.S. Positioning of a double-lumen endobronchal tube without the aid of any instruments: an implication for emergency management. J Trauma 49 (2000) 899-902
    • (2000) J Trauma , vol.49 , pp. 899-902
    • Bahk, J.H.1    Lim, Y.J.2    Kim, C.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.