메뉴 건너뛰기




Volumn 36, Issue 7, 2008, Pages 741-753

Stator winding inter-turn insulation fault detection in induction motors by symmetrical components method

Author keywords

Induction motors; Inter turn faults; Locus of current; Non overlapping area

Indexed keywords

AC MOTORS; ELECTRIC CURRENTS; ELECTRIC FAULT LOCATION; ELECTRIC NETWORK ANALYSIS; FAULT DETECTION; MEASUREMENT ERRORS; MOTORS; OPTICAL FILTERS; STATORS; TOOLS; WINDING;

EID: 46149122326     PISSN: 15325008     EISSN: 15325016     Source Type: Journal    
DOI: 10.1080/15325000701881993     Document Type: Article
Times cited : (16)

References (17)
  • 1
    • 0030704760 scopus 로고    scopus 로고
    • Stone, G. C., Lioyd, B. A., Campbell, S. R., and Sedding, H. G., Development of automatic, continuous partial discharge monitoring systems to detect motor and generator partial discharges, Electric Machines and Drives Conference Record, pp. MA2/3.1-MA2/3.3, Milwaukee, Wisconsin, 18-21 May 1997.
    • Stone, G. C., Lioyd, B. A., Campbell, S. R., and Sedding, H. G., "Development of automatic, continuous partial discharge monitoring systems to detect motor and generator partial discharges," Electric Machines and Drives Conference Record, pp. MA2/3.1-MA2/3.3, Milwaukee, Wisconsin, 18-21 May 1997.
  • 3
    • 0026886680 scopus 로고
    • Causes and analysis of stator and rotor failures in three phase squirrel cage induction motors
    • July/August
    • Bonnett, A. H., and Soukup, G. C., "Causes and analysis of stator and rotor failures in three phase squirrel cage induction motors," IEEE Trans. Industry Appl., Vol. 28, No. 4, pp. 921-937, July/August 1992.
    • (1992) IEEE Trans. Industry Appl , vol.28 , Issue.4 , pp. 921-937
    • Bonnett, A.H.1    Soukup, G.C.2
  • 6
    • 0035396689 scopus 로고    scopus 로고
    • Current signature analysis to detect induction motor faults
    • Thomson, W. T., and Fenger, M., "Current signature analysis to detect induction motor faults," IEEE Trans. Industry Appl. Mag., Vol. 7, No. 4, pp. 26-34, 2001.
    • (2001) IEEE Trans. Industry Appl. Mag , vol.7 , Issue.4 , pp. 26-34
    • Thomson, W.T.1    Fenger, M.2
  • 8
    • 0022757003 scopus 로고
    • Vibration and stray flux monitoring for unbalanced supply and inter-turn winding fault diagnosis in induction motors
    • July
    • Leonard, R. A., and Thomson, W. T., "Vibration and stray flux monitoring for unbalanced supply and inter-turn winding fault diagnosis in induction motors," British J. Non-destruc. Testing, Vol. 28, pp. 211-215, July 1986.
    • (1986) British J. Non-destruc. Testing , vol.28 , pp. 211-215
    • Leonard, R.A.1    Thomson, W.T.2
  • 9
    • 0028742406 scopus 로고
    • Detection and location of inter-turn short circuits in the stator winding of operating motors
    • December
    • Penman, J., Sedding, H. G., Lioyd, B. A., and Fink, W. T., "Detection and location of inter-turn short circuits in the stator winding of operating motors," IEEE Trans. Energy Convers., Vol. 9, No. 4, pp. 652-658, December 1994.
    • (1994) IEEE Trans. Energy Convers , vol.9 , Issue.4 , pp. 652-658
    • Penman, J.1    Sedding, H.G.2    Lioyd, B.A.3    Fink, W.T.4
  • 10
    • 0027831326 scopus 로고
    • An on-line method to detect incipient failure of turn insulation in random wound motors
    • December
    • Sottile, J., and Kohler, J. L., "An on-line method to detect incipient failure of turn insulation in random wound motors," IEEE Trans. Energy Convers., Vol. 8, No. 4, pp. 762-768, December 1993.
    • (1993) IEEE Trans. Energy Convers , vol.8 , Issue.4 , pp. 762-768
    • Sottile, J.1    Kohler, J.L.2
  • 11
    • 0033335228 scopus 로고    scopus 로고
    • Inter-turn stator winding fault diagnosis in three phase induction motors, by Park's vector approach
    • September
    • Cardoso, A. J. M., Cruz, S. M. A., and Fonseca, D. S. B., "Inter-turn stator winding fault diagnosis in three phase induction motors, by Park's vector approach," IEEE Trans. Energy Convers., Vol. 14, No. 3, pp. 595-598, September 1999.
    • (1999) IEEE Trans. Energy Convers , vol.14 , Issue.3 , pp. 595-598
    • Cardoso, A.J.M.1    Cruz, S.M.A.2    Fonseca, D.S.B.3
  • 13
    • 0344443880 scopus 로고    scopus 로고
    • Induction motor stator faults diagnosis by a current concordia pattern-based fuzzy decision system
    • December
    • Zidani, F., Benbouzid, M. E. H., Diallo, D., and Nait-Said, M. S., "Induction motor stator faults diagnosis by a current concordia pattern-based fuzzy decision system," IEEE Trans. Energy Convers., Vol. 18, No. 4, pp. 469-475, December 2003.
    • (2003) IEEE Trans. Energy Convers , vol.18 , Issue.4 , pp. 469-475
    • Zidani, F.1    Benbouzid, M.E.H.2    Diallo, D.3    Nait-Said, M.S.4
  • 14
    • 15044343813 scopus 로고    scopus 로고
    • A review of stator fault monitoring techniques of induction motors
    • March
    • Siddique, A., Yadava, G. S., and Singh, B., "A review of stator fault monitoring techniques of induction motors," IEEE Trans. Energy Convers., Vol. 20, No. 1, pp. 106-114, March 2005.
    • (2005) IEEE Trans. Energy Convers , vol.20 , Issue.1 , pp. 106-114
    • Siddique, A.1    Yadava, G.S.2    Singh, B.3
  • 15
    • 0036754027 scopus 로고    scopus 로고
    • Condition monitoring of stator winding in induction motors: Part I and II - experimental investigation of the effective negative-sequence impedance detector
    • September/October
    • Kohler, J. L., Sottile, J., and Trutt, F. C., "Condition monitoring of stator winding in induction motors: Part I and II - experimental investigation of the effective negative-sequence impedance detector," IEEE Trans. Industry Appl., Vol. 38, No. 5, pp. 1447-1459, September/October 2002.
    • (2002) IEEE Trans. Industry Appl , vol.38 , Issue.5 , pp. 1447-1459
    • Kohler, J.L.1    Sottile, J.2    Trutt, F.C.3
  • 16
    • 29044434713 scopus 로고    scopus 로고
    • Induction motor: Fuzzy system for the detection of winding insulation condition and bearing wear
    • February
    • Ballal, M. S., Khan, Z. J., Suryawanshi, H. M., and Sonolikar, R. L., "Induction motor: Fuzzy system for the detection of winding insulation condition and bearing wear," Elect. Power Compon. Syst., Vol. 34, No. 2, pp. 159-171, February 2006.
    • (2006) Elect. Power Compon. Syst , vol.34 , Issue.2 , pp. 159-171
    • Ballal, M.S.1    Khan, Z.J.2    Suryawanshi, H.M.3    Sonolikar, R.L.4
  • 17
    • 33947399741 scopus 로고    scopus 로고
    • Adaptive neural fuzzy inference system for the detection of inter-turn insulation and bearing wear fault in induction motor
    • February
    • Ballal, M. S., Khan, Z. J., Suryawanshi, H. M., and Sonolikar, R. L., "Adaptive neural fuzzy inference system for the detection of inter-turn insulation and bearing wear fault in induction motor," IEEE Trans. Industrial Electron., Vol. 54, No. 1, pp. 250-259, February 2007.
    • (2007) IEEE Trans. Industrial Electron , vol.54 , Issue.1 , pp. 250-259
    • Ballal, M.S.1    Khan, Z.J.2    Suryawanshi, H.M.3    Sonolikar, R.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.