메뉴 건너뛰기




Volumn 31, Issue 4, 2008, Pages 317-322

Hemodialysis dialyzers contribute to contamination of air microemboli that bypass the alarm system in the air trap

Author keywords

Adverse events; Dialyzer; Hemodialysis; High flux; In vitro; Low flux; Micro bubbles; Microemboli

Indexed keywords

ALARM SYSTEMS; HEMODIALYZERS;

EID: 45949099161     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139880803100407     Document Type: Article
Times cited : (12)

References (19)
  • 5
    • 0242351688 scopus 로고    scopus 로고
    • Reduction of circulating microemboli in the subclavian vein of patients undergoing hemodialysis using pre-filled instead of dry dialysers
    • Droste DW, Beyna T, Frye B, Schulte V, Ringelstein EB, Schaefer RM. Reduction of circulating microemboli in the subclavian vein of patients undergoing hemodialysis using pre-filled instead of dry dialysers. Nephrol Dial Transplant 2003; 18: 2377-81.
    • (2003) Nephrol Dial Transplant , vol.18 , pp. 2377-2381
    • Droste, D.W.1    Beyna, T.2    Frye, B.3    Schulte, V.4    Ringelstein, E.B.5    Schaefer, R.M.6
  • 6
    • 0036200670 scopus 로고    scopus 로고
    • Detection of microemboli in the subclavian vein of patients undergoing hemodialysis and haemodiafiltration using pulsed Doppler ultrasound
    • Droste DW, Kuhne K, Schaefer RM, Ringelstein EB. Detection of microemboli in the subclavian vein of patients undergoing hemodialysis and haemodiafiltration using pulsed Doppler ultrasound. Nephrol Dial Transplant 2002; 17: 462-6.
    • (2002) Nephrol Dial Transplant , vol.17 , pp. 462-466
    • Droste, D.W.1    Kuhne, K.2    Schaefer, R.M.3    Ringelstein, E.B.4
  • 7
    • 0034001952 scopus 로고    scopus 로고
    • Ultrasound detection of microembolic signals in hemodialysis accesses
    • Woltmann D, Fatica RA, Rubin JM, Weitzel W. Ultrasound detection of microembolic signals in hemodialysis accesses. Am J Kidney Dis 2000; 35: 526-8.
    • (2000) Am J Kidney Dis , vol.35 , pp. 526-528
    • Woltmann, D.1    Fatica, R.A.2    Rubin, J.M.3    Weitzel, W.4
  • 8
    • 33847000176 scopus 로고    scopus 로고
    • The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis
    • Stegmayr B, Forsberg U, Jonsson P, Stegmayr C. The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis. Artif Organs 2007; 31: 162-6.
    • (2007) Artif Organs , vol.31 , pp. 162-166
    • Stegmayr, B.1    Forsberg, U.2    Jonsson, P.3    Stegmayr, C.4
  • 9
    • 45949086823 scopus 로고    scopus 로고
    • Increased extent of micro emboli are present in AV access and carotid artery of the patient after start of HD. (Abstract)
    • Forsberg U, Jonsson P. Stegmayr C, Stegmayr B. Increased extent of micro emboli are present in AV access and carotid artery of the patient after start of HD. (Abstract). Int J Artif Organs 2007; 30: 697.
    • (2007) Int J Artif Organs , vol.30 , pp. 697
    • Forsberg, U.1    Jonsson, P.2    Stegmayr, C.3    Stegmayr, B.4
  • 11
    • 34249310577 scopus 로고    scopus 로고
    • Development of air micro bubbles in the venous outlet line: An in vitro analysis of various air traps used for hemodialysis
    • Stegmayr CJ, Jonsson P, Forsberg U, Stegmayr BG. Development of air micro bubbles in the venous outlet line: an in vitro analysis of various air traps used for hemodialysis. Artif Organs 2007; 31: 483-8.
    • (2007) Artif Organs , vol.31 , pp. 483-488
    • Stegmayr, C.J.1    Jonsson, P.2    Forsberg, U.3    Stegmayr, B.G.4
  • 12
    • 24044484898 scopus 로고    scopus 로고
    • Hemodialysis machines and monitors
    • Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF eds, 5th ed. London, Great Britain: Kluwer Academic Publishers;
    • Polaschegg H-D, Levin NW. Hemodialysis machines and monitors. In: Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF (eds). Replacement of Renal Function by Dialysis, 5th ed. London, Great Britain: Kluwer Academic Publishers; 2004. pp 325-449.
    • (2004) Replacement of Renal Function by Dialysis , pp. 325-449
    • Polaschegg, H.-D.1    Levin, N.W.2
  • 14
    • 0021876957 scopus 로고
    • Gas bubble detection in fluid lines by means of pulsed Doppler ultrasound
    • Hatteland K, Semb BK. Gas bubble detection in fluid lines by means of pulsed Doppler ultrasound. Scand J Thorac Cardiovasc Surg 1985; 19: 119-23.
    • (1985) Scand J Thorac Cardiovasc Surg , vol.19 , pp. 119-123
    • Hatteland, K.1    Semb, B.K.2
  • 15
    • 0021235308 scopus 로고
    • Doppler ultrasonic detection of particulate release during hemodialysis with cellulose hollow-fiber and sorbent suspension reciprocating dialyzers
    • Badylak SF, Ash SR, Thornhill JA, Carr DJ. Doppler ultrasonic detection of particulate release during hemodialysis with cellulose hollow-fiber and sorbent suspension reciprocating dialyzers. Int J Artif Organs 1984; 8: 220-3.
    • (1984) Int J Artif Organs , vol.8 , pp. 220-223
    • Badylak, S.F.1    Ash, S.R.2    Thornhill, J.A.3    Carr, D.J.4
  • 16
    • 27144506167 scopus 로고    scopus 로고
    • Microbubbles: Pathophysiology and clinical implications
    • Barak M, Katz Y. Microbubbles: pathophysiology and clinical implications. Chest 2005; 128: 2918-32.
    • (2005) Chest , vol.128 , pp. 2918-2932
    • Barak, M.1    Katz, Y.2
  • 17
    • 0025311932 scopus 로고
    • Exercise tolerance and pulmonary gas exchange after deep saturation dives
    • Thorsen E, Hjelle J, Segadal K, Gulsvik A. Exercise tolerance and pulmonary gas exchange after deep saturation dives. J Appl Physiol 1990; 68: 1809-14.
    • (1990) J Appl Physiol , vol.68 , pp. 1809-1814
    • Thorsen, E.1    Hjelle, J.2    Segadal, K.3    Gulsvik, A.4
  • 18
    • 0034025975 scopus 로고    scopus 로고
    • Lung function over the first 3 years of a professional diving career
    • Skogstad M, Thorsen E, Haldorsen T. Lung function over the first 3 years of a professional diving career. Occup Environ Med 2000; 57: 390-5.
    • (2000) Occup Environ Med , vol.57 , pp. 390-395
    • Skogstad, M.1    Thorsen, E.2    Haldorsen, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.