메뉴 건너뛰기




Volumn 4, Issue , 2006, Pages 2488-2493

Count-rate performance of the discovery STE PET scanner using partial collimation

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; MATHEMATICAL MODELS; OPTICAL COLLIMATORS; POSITRON EMISSION TOMOGRAPHY;

EID: 38649140203     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2006.354416     Document Type: Conference Paper
Times cited : (3)

References (18)
  • 1
    • 0001093618 scopus 로고    scopus 로고
    • Quantitative Brain PET. Comparison of 2D and 3D Acquisitions on the GE Advance Scanner
    • V. Dhawan, K. Kazumata, W. Robeson, et al., "Quantitative Brain PET. Comparison of 2D and 3D Acquisitions on the GE Advance Scanner", Clin Positron Imaging, 1(2):135-144, 1998.
    • (1998) Clin Positron Imaging , vol.1 , Issue.2 , pp. 135-144
    • Dhawan, V.1    Kazumata, K.2    Robeson, W.3
  • 2
    • 0035020033 scopus 로고    scopus 로고
    • Comparison of 2-dimensional and 3-dimensional cardiac 82Rb PET studies
    • J.R. Votaw, M. White, "Comparison of 2-dimensional and 3-dimensional cardiac 82Rb PET studies", J Nucl Med 42, pp. 701-706, 2001.
    • (2001) J Nucl Med , vol.42 , pp. 701-706
    • Votaw, J.R.1    White, M.2
  • 3
    • 0032910694 scopus 로고    scopus 로고
    • Reduction of Radiation Exposure in PET Examinations By Data Acquisition in the 3D Mode
    • G. Brix, L.E. Adam, J. Zaers, H. Trohan, M.E. Bellemann, D. Mosske, and J. Doll, "Reduction of Radiation Exposure in PET Examinations By Data Acquisition in the 3D Mode", Nuklearmedizin 38, no. 3: 75-79, 1999.
    • (1999) Nuklearmedizin , vol.38 , Issue.3 , pp. 75-79
    • Brix, G.1    Adam, L.E.2    Zaers, J.3    Trohan, H.4    Bellemann, M.E.5    Mosske, D.6    Doll, J.7
  • 4
    • 0033024060 scopus 로고    scopus 로고
    • Capabilities of Two- and Three-Dimensional FDG-PET for Detecting Small Lesions and Lymph Nodes in the Upper Torso: A Dynamic Phantom Study
    • R.R. Raylman, P.V. Kison, and R.L. Wahl, "Capabilities of Two- and Three-Dimensional FDG-PET for Detecting Small Lesions and Lymph Nodes in the Upper Torso: A Dynamic Phantom Study", Eur J Nucl Med 26, no. 1:39-45, 1999.
    • (1999) Eur J Nucl Med , vol.26 , Issue.1 , pp. 39-45
    • Raylman, R.R.1    Kison, P.V.2    Wahl, R.L.3
  • 5
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts
    • Apr
    • S.C. Strother, M.E. Casey, E.J. Hoffman, "Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalent counts", IEEE Trans. Nucl Sci., vol. 37, no. 2, pp. 783-788, Apr. 1990.
    • (1990) IEEE Trans. Nucl Sci , vol.37 , Issue.2 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 7
    • 0037459552 scopus 로고    scopus 로고
    • Survey of parallel slat collimator designs for hybrid PET imaging
    • T.C. Rust, D.J. Kadrmas, "Survey of parallel slat collimator designs for hybrid PET imaging", Phys Med Biol 48(6):N97-104, 2003.
    • (2003) Phys Med Biol , vol.48 , Issue.6
    • Rust, T.C.1    Kadrmas, D.J.2
  • 9
    • 0035554627 scopus 로고    scopus 로고
    • M. Aykac, J. Uribe, H. Baghaei, L. Hongdi, W. Yu, L. Yaqiang, X. Tao, and W.-H. Wong, Septa Design Study for Volumetric Imaging in Positron Emission Tomography, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) 3:1251-4, 2002.
    • M. Aykac, J. Uribe, H. Baghaei, L. Hongdi, W. Yu, L. Yaqiang, X. Tao, and W.-H. Wong, "Septa Design Study for Volumetric Imaging in Positron Emission Tomography", 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) vol.3:1251-4, 2002.
  • 10
    • 0142095006 scopus 로고    scopus 로고
    • Brain Lesion Detectability Studies with a high Resolution PET Operation in No-Septa and Partial-Septa Configurations
    • H. Baghaei, W-H. Wong, J. Uribe, H. Li, M. Aykac, Y. Wang, Y. Liu, T. Xing, R. Farrel, "Brain Lesion Detectability Studies with a high Resolution PET Operation in No-Septa and Partial-Septa Configurations", IEEE Trans Nuc Sci 50:1364-69, 2003.
    • (2003) IEEE Trans Nuc Sci , vol.50 , pp. 1364-1369
    • Baghaei, H.1    Wong, W.-H.2    Uribe, J.3    Li, H.4    Aykac, M.5    Wang, Y.6    Liu, Y.7    Xing, T.8    Farrel, R.9
  • 15
    • 0002380407 scopus 로고    scopus 로고
    • The SimSET Program
    • M. Ljungberg, S. Strand, and M. King, Editors, Institute of Physics Publishing: Philadelphia
    • T.K. Lewellen, R.L. Harrison, S. Vannoy, "The SimSET Program", in Monte Carlo Calculations in Nuclear Medicine, p. 77-92, M. Ljungberg, S. Strand, and M. King, Editors, Institute of Physics Publishing: Philadelphia, 1998.
    • (1998) Monte Carlo Calculations in Nuclear Medicine , pp. 77-92
    • Lewellen, T.K.1    Harrison, R.L.2    Vannoy, S.3
  • 17
    • 84939045331 scopus 로고
    • A multi-crystal two dimensional BGO detector system for positron emission tomography
    • M.E. Casey and R. Nutt, "A multi-crystal two dimensional BGO detector system for positron emission tomography," IEEE Trans. Nucl. Sci., vol. 33, pp. 460-463, 1986.
    • (1986) IEEE Trans. Nucl. Sci , vol.33 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2
  • 18
    • 38549159436 scopus 로고    scopus 로고
    • R.L. Harrison, S.B. Gillispie, T.K. Lewellen, Design and implementation of a block detector simulation in SimSET, (these proceedings) Proceedings of the IEEE Nuclear Science Symposium I Medical Imaging Conference, San Diego, CA, 29 Oct.-4 Nov. 2006.
    • R.L. Harrison, S.B. Gillispie, T.K. Lewellen, "Design and implementation of a block detector simulation in SimSET", (these proceedings) Proceedings of the IEEE Nuclear Science Symposium I Medical Imaging Conference, San Diego, CA, 29 Oct.-4 Nov. 2006.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.