메뉴 건너뛰기




Volumn 17 IFMBE, Issue , 2007, Pages 320-323

Determination of the dynamic measurement error of EIT systems

Author keywords

Bio impedance; EIT system; Measurement error; Noise performance; Phantom

Indexed keywords

DIGITAL STORAGE; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE TOMOGRAPHY; IMAGE ENHANCEMENT; IMAGE RECONSTRUCTION; MEASUREMENT ERRORS; PHANTOMS; SYSTEMATIC ERRORS;

EID: 45749150148     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-73841-1_84     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 2
    • 0033995054 scopus 로고    scopus 로고
    • A simple method to check the dynamic performance of electrical impedance tomography systems
    • DOI 10.1088/0967-3334/21/1/307, PII S0967333400098889
    • Hahn G, Beer M, Frerichs I, Dudykevych T, Schröder T, Hellige G (2000) A simple method to check the dynamic performance of electrical impedance tomography systems. Physiological Measurement 21:53-60 (Pubitemid 30120670)
    • (2000) Physiological Measurement , vol.21 , Issue.1 , pp. 53-60
    • Hahn, G.1    Beer, M.2    Frerichs, I.3    Dudykevych, T.4    Schroder, T.5    Hellige, G.6
  • 4
    • 0024434847 scopus 로고
    • A dual-frequency electrical impedance tomography system
    • Griffiths H, Zhang Z (1989) A dual-frequency electrical impedance tomography system. Physics in medicine and biology 34:1465-1476 (Pubitemid 19245995)
    • (1989) Physics in Medicine and Biology , vol.34 , Issue.10 , pp. 1465-1476
    • Griffiths, H.1    Zhang, Z.2
  • 6
    • 0036171902 scopus 로고    scopus 로고
    • Design and performance of the UCLH MARK 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function
    • DOI 10.1088/0967-3334/23/1/314, PII S0967333402307652
    • Yerworth RJ, Bayford RH, Cusick G, Conway M, Holder DS (2002) Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function. Physiol Meas 23:149-158 (Pubitemid 34155074)
    • (2002) Physiological Measurement , vol.23 , Issue.1 , pp. 149-158
    • Yerworth, R.J.1    Bayford, R.H.2    Cusick, G.3    Conway, M.4    Holder, D.S.5
  • 7
    • 0024207932 scopus 로고
    • A phantom for electrical impedance tomography
    • Griffiths H (1988) A phantom for electrical impedance tomography. Clin Phys Physiol Meas 9 Suppl A:15-20
    • (1988) Clin Phys Physiol Meas , vol.9 , Issue.SUPPL. A , pp. 15-20
    • Griffiths, H.1
  • 8
    • 0029022106 scopus 로고
    • A Cole phantom for EIT
    • Griffiths H (1995) A Cole phantom for EIT. Physiol Meas 16:A29-38
    • (1995) Physiol Meas , vol.16
    • Griffiths, H.1
  • 11
    • 0030988850 scopus 로고    scopus 로고
    • Bioelectrical impedance techniques in medicine. Part III: Impedance imaging. First section: general concepts and hardware
    • Rigaud B, Morucci JP (1996) Bioelectrical impedance techniques in medicine. Part III: Impedance imaging. First section: general concepts and hardware. Critical reviews in biomedical engineering 24:467-597
    • (1996) Critical Reviews in Biomedical Engineering , vol.24 , pp. 467-597
    • Rigaud, B.1    Morucci, J.P.2
  • 12
    • 0033999538 scopus 로고    scopus 로고
    • Systematic errors in multi-frequency EIT
    • Schlappa J, Annese E, Griffiths H (2000) Systematic errors in multi-frequency EIT. Physiol Meas 21:111-118
    • (2000) Physiol Meas , vol.21 , pp. 111-118
    • Schlappa, J.1    Annese, E.2    Griffiths, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.