메뉴 건너뛰기




Volumn 29, Issue 6, 2008, Pages

Multivariate analysis of electrical impedance spectra for relaxed and contracted skeletal muscle

Author keywords

Bioimpedance; PCA; SIMCA; Skeletal muscle; Voluntary contraction

Indexed keywords

ELECTRIC IMPEDANCE MEASUREMENT; MULTIVARIANT ANALYSIS; PRINCIPAL COMPONENT ANALYSIS;

EID: 45749088171     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/29/6/S30     Document Type: Article
Times cited : (20)

References (18)
  • 2
    • 0034124861 scopus 로고    scopus 로고
    • Using localized impedance measurements to study muscle changes in injury and disease
    • Aaron R and Shiffman C A 2000 Using localized impedance measurements to study muscle changes in injury and disease Ann. New York Acad. Sci. 904 171-80
    • (2000) Ann. New York Acad. Sci. , vol.904 , pp. 171-180
    • Aaron, R.1    Shiffman, C.A.2
  • 3
    • 0033583578 scopus 로고    scopus 로고
    • Decision criteria for soft independent modelling of class analogy applied to near infrared data
    • De Maesschalck R, Candolfi A, Massart D L and Heuerding S 1999 Decision criteria for soft independent modelling of class analogy applied to near infrared data Chemometr. Intell. Lab. Syst. 47 65-77
    • (1999) Chemometr. Intell. Lab. Syst. , vol.47 , Issue.1 , pp. 65-77
    • De Maesschalck, R.1    Candolfi, A.2    Massart, D.L.3    Heuerding, S.4
  • 4
    • 33750572209 scopus 로고    scopus 로고
    • Assessing neuromuscular disease with multifrequency electrical impedance myography
    • Esper G J, Shiffman C A, Aaron R, Lee K S and Rutkove S B 2006 Assessing neuromuscular disease with multifrequency electrical impedance myography Muscle Nerve 34 595-602
    • (2006) Muscle Nerve , vol.34 , Issue.5 , pp. 595-602
    • Esper, G.J.1    Shiffman, C.A.2    Aaron, R.3    Lee, K.S.4    Rutkove, S.B.5
  • 5
    • 0026012923 scopus 로고
    • Measurement of electrical impedance in organs-measuring equipment for research and clinical applications
    • Gersing E 1991 Measurement of electrical impedance in organs-measuring equipment for research and clinical applications Biomed. Technik. 36 6-11
    • (1991) Biomed. Technik. , vol.36 , pp. 6-11
    • Gersing, E.1
  • 6
    • 33751164183 scopus 로고    scopus 로고
    • Estuarine water classification using EEM spectroscopy and PARAFAC-SIMCA
    • Hall G J and Kenny J E 2007 Estuarine water classification using EEM spectroscopy and PARAFAC-SIMCA Anal. Chim. Acta 581 118-24
    • (2007) Anal. Chim. Acta , vol.581 , Issue.1 , pp. 118-124
    • Hall, G.J.1    Kenny, J.E.2
  • 7
    • 0032934216 scopus 로고    scopus 로고
    • Modelling the anisotropic electrical properties of skeletal muscle
    • Hart F X, Berner N J and McMillen R L 1999 Modelling the anisotropic electrical properties of skeletal muscle Phys. Med. Biol. 44 413-21
    • (1999) Phys. Med. Biol. , vol.44 , Issue.2 , pp. 413-421
    • Hart, F.X.1    Berner, N.J.2    McMillen, R.L.3
  • 9
    • 0035914563 scopus 로고    scopus 로고
    • Interaction with a phospholipid monolayer on a mercury electrode-multivariate analysis of impedance data
    • Lindholm-Sethson B, Geladi P and Nelson A 2001 Interaction with a phospholipid monolayer on a mercury electrode-multivariate analysis of impedance data Anal. Chim. Acta 446 121-30
    • (2001) Anal. Chim. Acta , vol.446 , Issue.1-2 , pp. 121-130
    • Lindholm-Sethson, B.1    Geladi, P.2    Nelson, A.3
  • 10
    • 0036199003 scopus 로고    scopus 로고
    • Localized bioimpedance analysis in the evaluation of neuromuscular disease
    • Rutkove S B, Aaron R and Shiffman C A 2002 Localized bioimpedance analysis in the evaluation of neuromuscular disease Muscle Nerve 25 390-7
    • (2002) Muscle Nerve , vol.25 , Issue.3 , pp. 390-397
    • Rutkove, S.B.1    Aaron, R.2    Shiffman, C.A.3
  • 11
    • 33744728014 scopus 로고    scopus 로고
    • Test-retest reproducibility of 50 kHz linear-electrical impedance myography
    • Rutkove S B, Lee K S, Shiffman C A and Aaron R 2006 Test-retest reproducibility of 50 kHz linear-electrical impedance myography Clin. Neurophysiol. 117 1244-8
    • (2006) Clin. Neurophysiol. , vol.117 , Issue.6 , pp. 1244-1248
    • Rutkove, S.B.1    Lee, K.S.2    Shiffman, C.A.3    Aaron, R.4
  • 12
    • 0037298294 scopus 로고    scopus 로고
    • Electrical impedance of muscle during isometric contraction
    • Shiffman C A, Aaron R and Rutkove S B 2003 Electrical impedance of muscle during isometric contraction Physiol. Meas. 24 213-34
    • (2003) Physiol. Meas. , vol.24 , Issue.1 , pp. 213-234
    • Shiffman, C.A.1    Aaron, R.2    Rutkove, S.B.3
  • 13
    • 33744729630 scopus 로고    scopus 로고
    • Editorial: Bridging function and structure of the neuromuscular system
    • Stegeman D F, Pillen S, Kleine B U and Zwarts M J 2006 Editorial: bridging function and structure of the neuromuscular system Clin. Neurophysiol. 117 1169-72
    • (2006) Clin. Neurophysiol. , vol.117 , Issue.6 , pp. 1169-1172
    • Stegeman, D.F.1    Pillen, S.2    Kleine, B.U.3    Zwarts, M.J.4
  • 14
    • 33846052389 scopus 로고    scopus 로고
    • Electrical impedance in bovine skeletal muscle as a model for the study of neuromuscular disease
    • Tarulli A W, Chin A B, Partida R A and Rutkove S B 2006 Electrical impedance in bovine skeletal muscle as a model for the study of neuromuscular disease Physiol. Meas. 27 1269-79
    • (2006) Physiol. Meas. , vol.27 , Issue.12 , pp. 1269-1279
    • Tarulli, A.W.1    Chin, A.B.2    Partida, R.A.3    Rutkove, S.B.4
  • 16
    • 0026697764 scopus 로고
    • Impedance plethysmography for blood flow measurements in human limbs: II. Influence of limb cross-sectional area.
    • Yamamoto Y, Yamamoto T and Aberg P A 1992 Impedance plethysmography for blood flow measurements in human limbs: II. Influence of limb cross-sectional area. Med. Biol. Eng. Comput. 30 518-24
    • (1992) Med. Biol. Eng. Comput. , vol.30 , Issue.5 , pp. 518-524
    • Yamamoto, Y.1    Yamamoto, T.2    Aberg, P.A.3
  • 17
    • 34548741776 scopus 로고    scopus 로고
    • An instrumentation amplifier as a front-end for a four-electrode bioimpedance measurement
    • Zagar T and Krizaj D 2007a An instrumentation amplifier as a front-end for a four-electrode bioimpedance measurement Physiol. Meas. 28 N57-65
    • (2007) Physiol. Meas. , vol.28 , Issue.8
    • Zagar, T.1    Krizaj, D.2
  • 18
    • 70350394093 scopus 로고    scopus 로고
    • Electrical impedance of relaxed and contracted skeletal muscle
    • Zagar T and Krizaj D 2007b Electrical impedance of relaxed and contracted skeletal muscle IFMBE Proc.-ICEBI 2007 (29 Aug.-2 Sep. 2007, Graz, Austria) vol 17 pp 711-4
    • (2007) IFMBE Proc.-ICEBI 2007 , vol.17 , pp. 711-714
    • Zagar, T.1    Krizaj, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.