메뉴 건너뛰기




Volumn 28, Issue 8, 2007, Pages

An instrumentation amplifier as a front-end for a four-electrode bioimpedance measurement

Author keywords

Auto balancing bridge; Bioimpedance measurement interface; Four electrode method; Instrumentation; Measurement errors

Indexed keywords

ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC NETWORK ANALYSIS; ELECTRODES;

EID: 34548741776     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/28/8/N03     Document Type: Article
Times cited : (12)

References (13)
  • 1
    • 0029819404 scopus 로고    scopus 로고
    • Current approaches to analogue instrumentation design in electrical impedance tomography
    • Boone K G and Holder D S 1996 Current approaches to analogue instrumentation design in electrical impedance tomography Physiol. Meas. 17 229-47
    • (1996) Physiol. Meas. , vol.17 , Issue.4 , pp. 229-247
    • Boone, K.G.1    Holder, D.S.2
  • 2
    • 0029831174 scopus 로고    scopus 로고
    • A parallel broadband real-time system for electrical impedance tomography
    • Casas O, Rosell J, Bragos R, Lozano A and Riu P J 1996 A parallel broadband real-time system for electrical impedance tomography Physiol. Meas. 17 A1-6
    • (1996) Physiol. Meas. , vol.17 , Issue.4 A
    • Casas, O.1    Rosell, J.2    Bragos, R.3    Lozano, A.4    Riu, P.J.5
  • 3
    • 0026012923 scopus 로고
    • Measurement of electrical impedance in organs-measuring equipment for research and clinical applications
    • Geddes L A 1991 Measurement of electrical impedance in organs-measuring equipment for research and clinical applications Biomed. Technik 36 6-11
    • (1991) Biomed. Technik , vol.36 , pp. 6-11
    • Geddes, L.A.1
  • 5
    • 0025483042 scopus 로고
    • High-quality recording of bioelectric events: Part 1. Interference reduction, theory and practice
    • Metting van Rijn A C, Peper A and Grimbergen C A 1990 High-quality recording of bioelectric events: part 1. Interference reduction, theory and practice Med. Biol. Eng. Comput. 28 389-97
    • (1990) Med. Biol. Eng. Comput. , vol.28 , Issue.5 , pp. 389-397
    • Metting Van Rijn, A.C.1    Peper, A.2    Grimbergen, C.A.3
  • 6
    • 0027715230 scopus 로고
    • AC instrumentation amplifier for bioimpedance measurements
    • Pallas-Areny R and Webster J G 1993 AC instrumentation amplifier for bioimpedance measurements IEEE Trans. Biomed. Eng. 40 830-3
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , Issue.8 , pp. 830-833
    • Pallas-Areny, R.1    Webster, J.G.2
  • 7
    • 0032692751 scopus 로고    scopus 로고
    • Influence of electrode impedance changes on the common-mode rejection ratio in bioimpedance measurements
    • Petrova G I 1999 Influence of electrode impedance changes on the common-mode rejection ratio in bioimpedance measurements Physiol. Meas. 20 N11-9
    • (1999) Physiol. Meas. , vol.20 , Issue.4
    • Petrova, G.I.1
  • 8
    • 0030031759 scopus 로고    scopus 로고
    • Passive electrical properties of human stratum corneum in vitro depending on time after separation
    • Pliquett F and Pliquett U 1996 Passive electrical properties of human stratum corneum in vitro depending on time after separation Biophys. Chem. 58 205-10
    • (1996) Biophys. Chem. , vol.58 , Issue.1-2 , pp. 205-210
    • Pliquett, F.1    Pliquett, U.2
  • 9
    • 0029394737 scopus 로고
    • Multi-frequency static imaging in electrical impedance tomography: Part 1. Instrumentation requirements
    • Riu P J, Rosell J, Lozano A and Pallas-Areny R 1995 Multi-frequency static imaging in electrical impedance tomography: part 1. Instrumentation requirements Med. Biol. Eng. Comput. 33 784-92
    • (1995) Med. Biol. Eng. Comput. , vol.33 , Issue.6 , pp. 784-792
    • Riu, P.J.1    Rosell, J.2    Lozano, A.3    Pallas-Areny, R.4
  • 11
    • 0036543677 scopus 로고    scopus 로고
    • Compensation of impedance meters when using an external front-end amplifier
    • Torrents J M and Pallas-Areny R 2002 Compensation of impedance meters when using an external front-end amplifier IEEE Trans. Instrum. Meas. 51 310-3
    • (2002) IEEE Trans. Instrum. Meas. , vol.51 , Issue.2 , pp. 310-313
    • Torrents, J.M.1    Pallas-Areny, R.2
  • 12
    • 0016938239 scopus 로고
    • Electrical properties of the epidermal stratum corneum
    • Yamamoto T and Yamamoto Y 1976 Electrical properties of the epidermal stratum corneum Med. Biol. Eng. 14 151-8
    • (1976) Med. Biol. Eng. , vol.14 , Issue.2 , pp. 151-158
    • Yamamoto, T.1    Yamamoto, Y.2
  • 13
    • 0033024950 scopus 로고    scopus 로고
    • Improvement of a front end for bioimpedance spectroscopy
    • Yelamos D, Casas O, Bragos R and Rosell J 1999 Improvement of a front end for bioimpedance spectroscopy Electrical Bioimpedance Methods: Applications to Medicine and Biotechnology, Ann. NY Acad. Sci. 873 306-12
    • (1999) Ann. NY Acad. Sci. , vol.873 , pp. 306-312
    • Yelamos, D.1    Casas, O.2    Bragos, R.3    Rosell, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.