-
2
-
-
0010486332
-
Advances in calorimetry for radiation dosimetry
-
ed K R Kase, B E Bjarngard and F H Attix (Orlando: Academic)
-
Domen S R 1987 Advances in calorimetry for radiation dosimetry The Dosimetry of Ionizing Radiation vol II ed K R Kase, B E Bjarngard and F H Attix (Orlando: Academic) pp 245-320
-
(1987)
The Dosimetry of Ionizing Radiation
, vol.2
, pp. 245-320
-
-
Domen, S.R.1
-
3
-
-
0011869815
-
A sealed water calorimeter for measuring absorbed dose
-
Domen S R 1994 A sealed water calorimeter for measuring absorbed dose J. Res. Natl. Inst. Stand. Technol. 99 121-41
-
(1994)
J. Res. Natl. Inst. Stand. Technol.
, vol.99
, pp. 121-141
-
-
Domen, S.R.1
-
4
-
-
0030067620
-
The UK primary standard calorimeter for photon-beam absorbed dose measurement
-
DuSautoy A R 1996 The UK primary standard calorimeter for photon-beam absorbed dose measurement Phys. Med. Biol. 41 137-51
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 137-151
-
-
DuSautoy, A.R.1
-
5
-
-
0029875259
-
Characteristics of the absorbed dose to water standard at ENEA
-
Guerra A S, Laitano R F and Pimpinella M 1996 Characteristics of the absorbed dose to water standard at ENEA Phys. Med. Biol. 41 657-74
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 657-674
-
-
Guerra, A.S.1
Laitano, R.F.2
Pimpinella, M.3
-
7
-
-
0025762425
-
Absorbed dose calorimetry using various aqueous solutions
-
Klassen N V and Ross C K 1991 Absorbed dose calorimetry using various aqueous solutions Radiat. Phys. Chem. 38 95-104
-
(1991)
Radiat. Phys. Chem.
, vol.38
, pp. 95-104
-
-
Klassen, N.V.1
Ross, C.K.2
-
8
-
-
0036508163
-
Water calorimetry: A correction to the heat defect calculations
-
Klassen N V and Ross C K 2002 Water calorimetry: a correction to the heat defect calculations J. Res. Natl. Inst. Stand. Technol. 107 171-8
-
(2002)
J. Res. Natl. Inst. Stand. Technol.
, vol.107
, pp. 171-178
-
-
Klassen, N.V.1
Ross, C.K.2
-
10
-
-
4544244411
-
The OFMET sealed water calorimeter
-
ed A J Williams and K E Rosser (Teddington, UK: National Physical Laboratory)
-
Medin J, Seuntjens J, Klassen N, Ross C and Stucki G 1999 The OFMET sealed water calorimeter Proc. NPL Workshop on Recent Advances in Calorimetric Absorbed Dose Standards ed A J Williams and K E Rosser (Teddington, UK: National Physical Laboratory) pp 65-73
-
(1999)
Proc. NPL Workshop on Recent Advances in Calorimetric Absorbed Dose Standards
, pp. 65-73
-
-
Medin, J.1
Seuntjens, J.2
Klassen, N.3
Ross, C.4
Stucki, G.5
-
11
-
-
0001566198
-
Measurements of heat capacity and heat of vaporization of water in the range 0 to 100 °C
-
Osborne N S, Stimson H F and Ginnings D C 1939 Measurements of heat capacity and heat of vaporization of water in the range 0 to 100 °C J. Res. Natl. Bur. Stand. 23 197-259
-
(1939)
J. Res. Natl. Bur. Stand.
, vol.23
, pp. 197-259
-
-
Osborne, N.S.1
Stimson, H.F.2
Ginnings, D.C.3
-
12
-
-
0030046847
-
Water calorimetry for radiation dosimetry
-
Ross C K and Klassen N V 1996 Water calorimetry for radiation dosimetry Phys. Med. Biol. 41 1-29
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 1-29
-
-
Ross, C.K.1
Klassen, N.V.2
-
15
-
-
0033040827
-
Correction factors and performance of a 4 °C sealed water calorimeter
-
Seuntjens J and Palmans H 1999 Correction factors and performance of a 4 °C sealed water calorimeter Phys. Med. Biol. 44 627-46
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 627-646
-
-
Seuntjens, J.1
Palmans, H.2
-
16
-
-
0011331874
-
Study of the relative heat defect and correction factors of a water calorimetric determination of absorbed dose to water in high-energy photon beams
-
(Vienna: IAEA)
-
Seuntjens J, Van der Plaetsen A, Van Laere K and Thierens H 1993 Study of the relative heat defect and correction factors of a water calorimetric determination of absorbed dose to water in high-energy photon beams Proc. Symp. on Measurement Assurance in Dosimetry IAEA-SM-330/6 (Vienna: IAEA) pp 45-59
-
(1993)
Proc. Symp. on Measurement Assurance in Dosimetry IAEA-SM-330/6
, pp. 45-59
-
-
Seuntjens, J.1
Van der Plaetsen, A.2
Van Laere, K.3
Thierens, H.4
-
17
-
-
0009571190
-
Revisiting convective motion in stagnant water calorimeters operated at room temperature
-
ed A J Williams and K E Rosser (Teddington, UK: National Physical Laboratory)
-
Seuntjens J P, Kawrakow I and Ross C K 1999a Revisiting convective motion in stagnant water calorimeters operated at room temperature Proc. NPL Workshop on Recent Advances in Calorimetric Absorbed Dose Standards ed A J Williams and K E Rosser (Teddington, UK: National Physical Laboratory) pp 103-19
-
(1999)
Proc. NPL Workshop on Recent Advances in Calorimetric Absorbed Dose Standards
, pp. 103-119
-
-
Seuntjens, J.P.1
Kawrakow, I.2
Ross, C.K.3
-
18
-
-
0006491004
-
A Status Report on the NRC Sealed Water Calorimeter
-
NRC Report PIRS-0584 (Ottawa: National Research Council)
-
Seuntjens J P, Ross C K, Klassen N V and Shortt K R 1999b A Status Report on the NRC Sealed Water Calorimeter NRC Report PIRS-0584 (Ottawa: National Research Council)
-
(1999)
-
-
Seuntjens, J.P.1
Ross, C.K.2
Klassen, N.V.3
Shortt, K.R.4
-
19
-
-
0034500295
-
Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams
-
Seuntjens J P, Ross C K, Shortt K R and Rogers D W O 2000 Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams Med. Phys. 27 2763-79
-
(2000)
Med. Phys.
, vol.27
, pp. 2763-2779
-
-
Seuntjens, J.P.1
Ross, C.K.2
Shortt, K.R.3
Rogers, D.W.O.4
-
20
-
-
0033856077
-
Comparison of dosimetry calibration factors at the NRCC and the NIST
-
Shortt K, Shobe J and Domen S 2000 Comparison of dosimetry calibration factors at the NRCC and the NIST Med. Phys. 27 1644-54
-
(2000)
Med. Phys.
, vol.27
, pp. 1644-1654
-
-
Shortt, K.1
Shobe, J.2
Domen, S.3
|