1
-
-
0021062111
-
A protocol for the determination of absorbed dose from high-energy photon and electron beams
-
AAPM 1983 A protocol for the determination of absorbed dose from high-energy photon and electron beams Med. Phys. 10 741-71
-
(1983)
Med. Phys.
, vol.10
, pp. 741-771
-
-
-
2
-
-
0025670164
-
Uncertainties in dosimetric data and beam calibration
-
Andreo P 1990 Uncertainties in dosimetric data and beam calibration Int. J. Radiat. Oncol. Biol. Phys. 19 1233-47
-
(1990)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.19
, pp. 1233-1247
-
-
Andreo, P.1
-
3
-
-
0026677952
-
Absorbed dose beam quality factors for the dosimetry of high-energy photon beams
-
_1992 Absorbed dose beam quality factors for the dosimetry of high-energy photon beams Phys. Med. Biol. 37 2189-211
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 2189-2211
-
-
-
4
-
-
0018361005
-
The partition of kerma to account for bremsstrahlung
-
Attix F H 1979 The partition of kerma to account for bremsstrahlung Health Phys 36 347-54
-
(1979)
Health Phys
, vol.36
, pp. 347-354
-
-
Attix, F.H.1
-
5
-
-
0025054671
-
A proposal for the calibration of plane-parallel chambers by accredited dosimetry calibration laboratories
-
_1990 A proposal for the calibration of plane-parallel chambers by accredited dosimetry calibration laboratories Med. Phys. 17 931-3
-
(1990)
Med. Phys.
, vol.17
, pp. 931-933
-
-
-
6
-
-
0024337306
-
Gap correction for the calorimetric measurement of absorbed dose in graphite with a Co-60 beam
-
Boutillon M 1989 Gap correction for the calorimetric measurement of absorbed dose in graphite with a Co-60 beam Phys. Med. Biol. 34 1809-21
-
(1989)
Phys. Med. Biol.
, vol.34
, pp. 1809-1821
-
-
Boutillon, M.1
-
7
-
-
15844384904
-
Comparison of primary water absorbed dose standards
-
CCEMRI(I)/93-33 (Paris: Offi lib)
-
Boutillon M, Coursey B M, Hohlfeld K, Owen B and Rogers DWO 1993 Comparison of primary water absorbed dose standards BIPM Comité Consultatif pour les Etalons de Mesure des Rayonnements Ionisants, Section (I) CCEMRI(I)/93-33 (Paris: Offi lib)
-
(1993)
BIPM Comité Consultatif pour les Etalons de Mesure des Rayonnements Ionisants, Section (I)
-
-
Boutillon, M.1
Coursey, B.M.2
Hohlfeld, K.3
Owen, B.4
Rogers, D.W.O.5
-
8
-
-
0028074615
-
Absorbed-dose calibration in high-energy photon beams at the National Physical Laboratory: Conversion procedure
-
Burns J E 1994 Absorbed-dose calibration in high-energy photon beams at the National Physical Laboratory: conversion procedure Phys. Med. Biol. 39 1555-75
-
(1994)
Phys. Med. Biol.
, vol.39
, pp. 1555-1575
-
-
Burns, J.E.1
-
9
-
-
13344265105
-
Conversion of absorbed dose calibration from graphite into water
-
RSA (EXT) 7 (Teddington: National Physical Laboratory)
-
Burns J E and Dale J W G 1990 Conversion of absorbed dose calibration from graphite into water NPL Report RSA (EXT) 7 (Teddington: National Physical Laboratory)
-
(1990)
NPL Report
-
-
Burns, J.E.1
Dale, J.W.G.2
-
10
-
-
0019137194
-
Displacement corrections used in absorbed dose determination
-
Cunningham J R and Sontag M R 1980 Displacement corrections used in absorbed dose determination Med. Phys. 7 672-6
-
(1980)
Med. Phys.
, vol.7
, pp. 672-676
-
-
Cunningham, J.R.1
Sontag, M.R.2
-
11
-
-
0016104364
-
Heat-loss compensated calorimeter: Theory, design and performance
-
Domen S R and Lamperti P J A 1974 Heat-loss compensated calorimeter: theory, design and performance J. Res. NBS A 78 595-610
-
(1974)
J. Res. NBS A
, vol.78
, pp. 595-610
-
-
Domen, S.R.1
Lamperti, P.J.A.2
-
12
-
-
15844380652
-
The ENEA standard for absorbed dose to graphite for Co-60 gamma radiation. The graphite calorimeter
-
Guerra A S, Laitano R F and Pimpinella M 1992 The ENEA standard for absorbed dose to graphite for Co-60 gamma radiation. the graphite calorimeter ENEA-INMRI Internal Report 3/92
-
(1992)
ENEA-INMRI Internal Report 3/92
-
-
Guerra, A.S.1
Laitano, R.F.2
Pimpinella, M.3
-
13
-
-
15844377140
-
Gap effect at various depths in graphite calorimeter: Experimental determination with variable field size at Co-60 gamma-ray beam
-
Teddington: National Physical Laboratory
-
_1994 Gap effect at various depths in graphite calorimeter: experimental determination with variable field size at Co-60 gamma-ray beam Proc. NPL Workshop on Calorimetry in Radiation Dosimetry (Teddington, 1994) (Teddington: National Physical Laboratory) pp 247-57
-
(1994)
Proc. NPL Workshop on Calorimetry in Radiation Dosimetry (Teddington, 1994)
, pp. 247-257
-
-
-
14
-
-
0029031216
-
Q, for ionization chambers used in photon and electron dosimetry
-
Q, for ionization chambers used in photon and electron dosimetry Phys. Med. Biol. 40 1177-90
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1177-1190
-
-
-
15
-
-
0020213666
-
Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV
-
Hubbell J H 1982 Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV Int. J. Appl. Radiat. Isot. 33 1269-90
-
(1982)
Int. J. Appl. Radiat. Isot.
, vol.33
, pp. 1269-1290
-
-
Hubbell, J.H.1
-
16
-
-
0003484991
-
Absorbed-dose determination in photon and electron beams: An international code of practice
-
Vienna: IAEA
-
IAEA 1987 Absorbed-dose determination in photon and electron beams: an international code of practice IAEA Technical Report Series 277 (Vienna: IAEA)
-
(1987)
IAEA Technical Report Series 277
-
-
-
18
-
-
0027304227
-
Beam quality specification for photon beam dosimetry
-
Kosunen A and Rogers D W O 1993 Beam quality specification for photon beam dosimetry Med. Phys. 20 1181-8
-
(1993)
Med. Phys.
, vol.20
, pp. 1181-1188
-
-
Kosunen, A.1
Rogers, D.W.O.2
-
20
-
-
0000574337
-
The variation of scattered X-rays with density in an irradiated body
-
O'Connor J E 1957 The variation of scattered X-rays with density in an irradiated body Phys. Med. Biol. 1 352-69
-
(1957)
Phys. Med. Biol.
, vol.1
, pp. 352-369
-
-
O'Connor, J.E.1
-
21
-
-
13344293378
-
NPL absorbed dose graphite calorimeter - Correction for the effect of the gaps around the core in high energy photon radiation
-
RSA(EXT)12
-
Owen B and DuSautoy A R 1990 NPL absorbed dose graphite calorimeter - correction for the effect of the gaps around the core in high energy photon radiation NPL Report RSA(EXT)12
-
(1990)
NPL Report
-
-
Owen, B.1
DuSautoy, A.R.2
-
22
-
-
0026039813
-
Correction for the effect of the gaps around the core of an absorbed dose graphite calorimeter in high energy photon radiation
-
_1991 Correction for the effect of the gaps around the core of an absorbed dose graphite calorimeter in high energy photon radiation Phys. Med. Biol. 36 1699-704
-
(1991)
Phys. Med. Biol.
, vol.36
, pp. 1699-1704
-
-
-
24
-
-
0019612008
-
The graphite calorimeter as a standard for absorbed dose for cobalt-60 gamma radiation
-
Pruitt J S, Domen S R and Loevinger R 1981 The graphite calorimeter as a standard for absorbed dose for cobalt-60 gamma radiation J. Res. NBS 86 495-502
-
(1981)
J. Res. NBS
, vol.86
, pp. 495-502
-
-
Pruitt, J.S.1
Domen, S.R.2
Loevinger, R.3
-
25
-
-
0020058417
-
The photon-fluence scaling theorem for Compton-scattered radiation
-
Pruitt J S and Loevinger R 1982 The photon-fluence scaling theorem for Compton-scattered radiation Med. Phys. 9 176-9
-
(1982)
Med. Phys.
, vol.9
, pp. 176-179
-
-
Pruitt, J.S.1
Loevinger, R.2
-
26
-
-
66449123173
-
Dose for nonelectronic equilibrium conditions
-
Roesch W C 1958 Dose for nonelectronic equilibrium conditions Radiat. Res. 9 399-410
-
(1958)
Radiat. Res.
, vol.9
, pp. 399-410
-
-
Roesch, W.C.1
-
29
-
-
0021493702
-
A graphite absorbed-dose calorimeter in the quasi-isothermal mode of operation
-
Witzani J, Duftschmid K E, Strachotinsky Ch and Leitner A 1984 A graphite absorbed-dose calorimeter in the quasi-isothermal mode of operation Metrologia 20 73-9
-
(1984)
Metrologia
, vol.20
, pp. 73-79
-
-
Witzani, J.1
Duftschmid, K.E.2
Strachotinsky, Ch.3
Leitner, A.4
|