메뉴 건너뛰기




Volumn 34, Issue 1-3, 1996, Pages 435-440

A new pH-ISFET based dissolved oxygen sensor by employing electrolysis of oxygen

Author keywords

Clark type sensor; Dissolved oxygen sensor; Oxygen electrolysis; pH ISFET; Working electrode

Indexed keywords


EID: 0042441444     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(97)80017-2     Document Type: Article
Times cited : (49)

References (19)
  • 4
    • 0025254873 scopus 로고
    • Disposable oxygen electrodes fabricated by semiconductor techniques and their application to biosensors
    • H. Suzuki, N. Kojima, A. Sugama, F. Takei and K. Ikegami, Disposable oxygen electrodes fabricated by semiconductor techniques and their application to biosensors, Sensors and Actuators B, 1 (1990) 528-532.
    • (1990) Sensors and Actuators B , vol.1 , pp. 528-532
    • Suzuki, H.1    Kojima, N.2    Sugama, A.3    Takei, F.4    Ikegami, K.5
  • 6
    • 0024969501 scopus 로고
    • Signal-to-noise ratio in microelectrode-array based electrochemical detectors
    • S.G. Weber, Signal-to-noise ratio in microelectrode-array based electrochemical detectors, Anal. Chem., 61 (1989) 295-302.
    • (1989) Anal. Chem. , vol.61 , pp. 295-302
    • Weber, S.G.1
  • 8
    • 0026924315 scopus 로고
    • Reversible potentiometric oxygen sensors based on polymeric and metallic film electrodes
    • H.S. Yim and M.E. Meyerhoff, Reversible potentiometric oxygen sensors based on polymeric and metallic film electrodes, Anal. Chem. 64 (1992) 1777.
    • (1992) Anal. Chem. , vol.64 , pp. 1777
    • Yim, H.S.1    Meyerhoff, M.E.2
  • 10
    • 0022125833 scopus 로고
    • An ISFET-based microlitre titrator : Integration of a chemical sensor-actuator system
    • B.H. van der Schoot and P. Bergveld, An ISFET-based microlitre titrator : integration of a chemical sensor-actuator system, Sensors and Actuators, 8 (1985) 11-22.
    • (1985) Sensors and Actuators , vol.8 , pp. 11-22
    • Van Der Schoot, B.H.1    Bergveld, P.2
  • 12
    • 0025306054 scopus 로고
    • Modelling of non-steady-state concentration profiles at ISFET-based coulometric sensor-actuator systems
    • W. Olthuis, J. Luo, B.H. van der Schoot, P. Bergveld and M. Bos, W.E. van der Linden, Modelling of non-steady-state concentration profiles at ISFET-based coulometric sensor-actuator systems, Anal. Chim. Acta., 229 (1990) 71-81.
    • (1990) Anal. Chim. Acta. , vol.229 , pp. 71-81
    • Olthuis, W.1    Luo, J.2    Van Der Schoot, B.H.3    Bergveld, P.4    Bos, M.5    Van Der Linden, W.E.6
  • 13
    • 0011739614 scopus 로고
    • Some considerations of the steady-state and transient behaviour of membrane-covered dissolved oxygen detectors
    • J.M. Hale and M.L. Hitchman, Some considerations of the steady-state and transient behaviour of membrane-covered dissolved oxygen detectors, J. Electroanal. Chem., 107 (1980) 281-294.
    • (1980) J. Electroanal. Chem. , vol.107 , pp. 281-294
    • Hale, J.M.1    Hitchman, M.L.2
  • 14
    • 0021469027 scopus 로고
    • An experimental study of oxygen probe linearity and transient characteristics in the high oxygen concentration range
    • V. Linek, P. Benes and P. Vacek, An experimental study of oxygen probe linearity and transient characteristics in the high oxygen concentration range, J. Electroanal. Chem., 169 (1984) 233-257.
    • (1984) J. Electroanal. Chem. , vol.169 , pp. 233-257
    • Linek, V.1    Benes, P.2    Vacek, P.3
  • 15
    • 0022067157 scopus 로고
    • The effect of the accumulation of cathodic reaction products in Clark oxygen probes on probe linearity, signal overshooting, tailing and hysteresis of transient characteristics for step changes in the concentration of oxygen
    • V. Linek, J. Sinkule and V. Vacek, The effect of the accumulation of cathodic reaction products in Clark oxygen probes on probe linearity, signal overshooting, tailing and hysteresis of transient characteristics for step changes in the concentration of oxygen, J. Electroanal. Chem., 187 (1985) 1-30.
    • (1985) J. Electroanal. Chem. , vol.187 , pp. 1-30
    • Linek, V.1    Sinkule, J.2    Vacek, V.3
  • 19
    • 0025244545 scopus 로고
    • A smart sensor for the voltammetric measurement of oxygen or glucose concentration
    • W. Sansen, D. de Wachter, L. Callewaert and M. Lambrechts, A smart sensor for the voltammetric measurement of oxygen or glucose concentration, Sensors and Actuators B, 1 (1990) 298-302.
    • (1990) Sensors and Actuators B , vol.1 , pp. 298-302
    • Sansen, W.1    De Wachter, D.2    Callewaert, L.3    Lambrechts, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.