-
1
-
-
0022470978
-
ROC methodology in radiologic imaging
-
Metz C.E. ROC methodology in radiologic imaging. Invest Radiol. 21:1986;720-733
-
(1986)
Invest Radiol
, vol.21
, pp. 720-733
-
-
Metz, C.E.1
-
2
-
-
0014265939
-
Maximum likelihood estimation of parameters of signal detection theory-a direct solution
-
Dorfman D.D., Alf E. Maximum likelihood estimation of parameters of signal detection theory-a direct solution. Psychometrika. 33:1968;117-124
-
(1968)
Psychometrika
, vol.33
, pp. 117-124
-
-
Dorfman, D.D.1
Alf, E.2
-
3
-
-
38649132833
-
Maximum-likelihood estimation of parameters of signal detection theory and determination of confidence intervals-rating method data
-
Dorfman D.D., Alf E. Maximum-likelihood estimation of parameters of signal detection theory and determination of confidence intervals-rating method data. J Math Psychology. 6:1969;487-496
-
(1969)
J Math Psychology
, vol.6
, pp. 487-496
-
-
Dorfman, D.D.1
Alf, E.2
-
4
-
-
0020083498
-
The meaning and use of the area under a receiver operating characteristic (ROC) curve
-
Hanley J.A., McNeil B.J. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. 143:1982;29-36
-
(1982)
Radiology
, vol.143
, pp. 29-36
-
-
Hanley, J.A.1
McNeil, B.J.2
-
5
-
-
0020524559
-
A method of comparing the areas under receiver operating characteristic curves derived from the same cases
-
Hanley J.A., McNeil B.J. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology. 148:1983;839-843
-
(1983)
Radiology
, vol.148
, pp. 839-843
-
-
Hanley, J.A.1
McNeil, B.J.2
-
6
-
-
0023710206
-
Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
-
DeLong E.R., DeLong D.M., Clarke-Pearson D.L. Comparing the areas under two or more correlated receiver operating characteristic curves a nonparametric approach. Biometrics. 44:1988;837-844
-
(1988)
Biometrics
, vol.44
, pp. 837-844
-
-
Delong, E.R.1
Delong, D.M.2
Clarke-Pearson, D.L.3
-
7
-
-
0024370623
-
Analyzing a portion of the ROC curve
-
McClish D.K. Analyzing a portion of the ROC curve. Med Decis Making. 9:1989;190-195
-
(1989)
Med Decis Making
, vol.9
, pp. 190-195
-
-
McClish, D.K.1
-
9
-
-
0026624821
-
Answering unanswered questions: Proposal for a shared resource in clinical diagnostic radiology research
-
Beam C.A., Baker M.E., Paine S.S., Sostman H.D., Sullivan D.C. Answering unanswered questions proposal for a shared resource in clinical diagnostic radiology research. Radiology. 183:1992;619-620
-
(1992)
Radiology
, vol.183
, pp. 619-620
-
-
Beam, C.A.1
Baker, M.E.2
Paine, S.S.3
Sostman, H.D.4
Sullivan, D.C.5
-
10
-
-
0029347646
-
Multi-reader ROC studies: A comparison of study designs
-
Obuchowski N.A. Multi-reader ROC studies a comparison of study designs. Acad Radiol. 2:1995;709-716
-
(1995)
Acad Radiol
, vol.2
, pp. 709-716
-
-
Obuchowski, N.A.1
-
11
-
-
0024443297
-
Receiver operating characteristic (ROC) methodology: The state of the art
-
Hanley J.A. Receiver operating characteristic (ROC) methodology the state of the art. Crit Rev Diagn Imaging. 29:1989;307-335
-
(1989)
Crit Rev Diagn Imaging
, vol.29
, pp. 307-335
-
-
Hanley, J.A.1
-
12
-
-
0026664983
-
Receiver operating characteristic rating analysis: Generalization to the population of readers and patients with the jackknife method
-
Dorfman D.D., Berbaum K.S., Metz C.E. Receiver operating characteristic rating analysis generalization to the population of readers and patients with the jackknife method. Invest Radiol. 27:1992;723-731
-
(1992)
Invest Radiol
, vol.27
, pp. 723-731
-
-
Dorfman, D.D.1
Berbaum, K.S.2
Metz, C.E.3
-
13
-
-
0034557373
-
A general class of hierarchical ordinal regression models with applications to correlated ROC analysis
-
Ishwaran H., Gatsonis C.A. A general class of hierarchical ordinal regression models with applications to correlated ROC analysis. Can J Stat. 28:2000;731-750
-
(2000)
Can J Stat
, vol.28
, pp. 731-750
-
-
Ishwaran, H.1
Gatsonis, C.A.2
-
14
-
-
0031752721
-
Monte carlo validation of a multireader method for receiver operating characteristic discrete rating data: Factorial experimental design
-
Dorfman D.D., Berbaum K.S., Lenth R.V., Chen Y.F., Donaghy B.A. Monte carlo validation of a multireader method for receiver operating characteristic discrete rating data factorial experimental design. Acad Radiol. 5:1998;591-602
-
(1998)
Acad Radiol
, vol.5
, pp. 591-602
-
-
Dorfman, D.D.1
Berbaum, K.S.2
Lenth, R.V.3
Chen, Y.F.4
Donaghy, B.A.5
-
15
-
-
4544283507
-
-
LABMRMC. Available at: http://xray.bsd.uchicago.edu/krl/KRL_ROC/ software_index.htm.
-
-
-
-
17
-
-
0009060722
-
Analysis of correlated ROC areas in diagnostic testing
-
Song H.H. Analysis of correlated ROC areas in diagnostic testing. Biometrics. 53:1997;370-382
-
(1997)
Biometrics
, vol.53
, pp. 370-382
-
-
Song, H.H.1
-
18
-
-
0000889433
-
Hypothesis testing of the diagnostic accuracy for multiple diagnostic tests: An ANOVA approach with dependent observations
-
Obuchowski N.A., Rockette H.E. Hypothesis testing of the diagnostic accuracy for multiple diagnostic tests an ANOVA approach with dependent observations. Commun Stat Simul Computation. 24:1995;285-308
-
(1995)
Commun Stat Simul Computation
, vol.24
, pp. 285-308
-
-
Obuchowski, N.A.1
Rockette, H.E.2
-
19
-
-
0029257706
-
Multi-reader multi-modality ROC studies: Hypothesis testing and sample size estimation using an ANOVA approach with dependent observations with rejoinder
-
Obuchowski N.A. Multi-reader multi-modality ROC studies hypothesis testing and sample size estimation using an ANOVA approach with dependent observations with rejoinder. Acad Radiol. 2:1995;S22-S29
-
(1995)
Acad Radiol
, vol.2
-
-
Obuchowski, N.A.1
-
20
-
-
4544263225
-
-
OBUMRM. Available at: html.http://www.bio.ri.ccf.org/OBUMRM/OBUMRM.html.
-
-
-
-
21
-
-
0034028155
-
Components-of-variance models and multiple-bootstrap experiments: An alternative method for random-effects, receiver operating characteristic analysis
-
Beiden S.V., Wagner R.F., Campbell G. Components-of-variance models and multiple-bootstrap experiments an alternative method for random-effects, receiver operating characteristic analysis. Acad Radiol. 7:2000;341-349
-
(2000)
Acad Radiol
, vol.7
, pp. 341-349
-
-
Beiden, S.V.1
Wagner, R.F.2
Campbell, G.3
-
22
-
-
0031202740
-
Variance-component modeling in the analysis of receiver operating characteristic index estimates
-
Roe C.A., Metz C.E. Variance-component modeling in the analysis of receiver operating characteristic index estimates. Acad Radiol. 4:1997;587-600
-
(1997)
Acad Radiol
, vol.4
, pp. 587-600
-
-
Roe, C.A.1
Metz, C.E.2
-
23
-
-
0034962147
-
Components-of-variance models for random-effects ROC analysis: The case of unequal variance structure across modalities
-
Beiden S.V., Wagner R.F., Campbell G., Metz C.E., Jiang Y. Components-of-variance models for random-effects ROC analysis the case of unequal variance structure across modalities. Acad Radiol. 8:2001;605-615
-
(2001)
Acad Radiol
, vol.8
, pp. 605-615
-
-
Beiden, S.V.1
Wagner, R.F.2
Campbell, G.3
Metz, C.E.4
Jiang, Y.5
-
24
-
-
0034949953
-
Analysis of uncertainties in estimates of components of variance in multivariate ROC analysis
-
Beiden S.V., Wagner R.F., Campbell G., Chan H.P. Analysis of uncertainties in estimates of components of variance in multivariate ROC analysis. Acad Radiol. 8:2001;616-622
-
(2001)
Acad Radiol
, vol.8
, pp. 616-622
-
-
Beiden, S.V.1
Wagner, R.F.2
Campbell, G.3
Chan, H.P.4
-
26
-
-
0034557372
-
Univariate and multirater ordinal cumulative link regression with covariate specific cutpoints
-
Ishwaran H. Univariate and multirater ordinal cumulative link regression with covariate specific cutpoints. Can J Stat. 28:2000;715-730
-
(2000)
Can J Stat
, vol.28
, pp. 715-730
-
-
Ishwaran, H.1
-
27
-
-
0029740924
-
Ordinal regression methodology for ROC curves derived from correlated data
-
Toledano A.Y., Gatsonis C. Ordinal regression methodology for ROC curves derived from correlated data. Stat Med. 15:1996;1807-1826
-
(1996)
Stat Med
, vol.15
, pp. 1807-1826
-
-
Toledano, A.Y.1
Gatsonis, C.2
-
28
-
-
4544238569
-
-
Chicago, IL: 79th RSNA Meetings. November 28-December 3
-
Van Dyke C.W., White R.D., Obuchowski N.A., Geisinger M.A., Lorig R.J., Meziane M.A. Cine MRI in the diagnosis of thoracic aortic dissection. 1993;79th RSNA Meetings, Chicago, IL. November 28-December 3
-
(1993)
Cine MRI in the Diagnosis of Thoracic Aortic Dissection
-
-
Van Dyke, C.W.1
White, R.D.2
Obuchowski, N.A.3
Geisinger, M.A.4
Lorig, R.J.5
Meziane, M.A.6
-
29
-
-
4544307995
-
Clinical evaluation of digital versus film-screen mammograms: Diagnostic accuracy and patient management
-
Powell K.A., Obuchowski N.A., Chilcote W.A., Barry M.M., Ganobcik S.N., Cardenosa G. Clinical evaluation of digital versus film-screen mammograms diagnostic accuracy and patient management. AJR Am J Roentgenol. 173:1990;889-894
-
(1990)
AJR Am J Roentgenol
, vol.173
, pp. 889-894
-
-
Powell, K.A.1
Obuchowski, N.A.2
Chilcote, W.A.3
Barry, M.M.4
Ganobcik, S.N.5
Cardenosa, G.6
-
30
-
-
0034068352
-
Effects of luminance and resolution on observer performance with chest radiographs
-
Herron J.M., Bender T.M., Campbell W.L., Sumkin J.H., Rockette H.E., Gur D. Effects of luminance and resolution on observer performance with chest radiographs. Radiology. 215:2000;169-174
-
(2000)
Radiology
, vol.215
, pp. 169-174
-
-
Herron, J.M.1
Bender, T.M.2
Campbell, W.L.3
Sumkin, J.H.4
Rockette, H.E.5
Gur, D.6
-
31
-
-
4544388399
-
-
Replaced by ROCKIT
-
CORROC2. a FORTRAN program written by C. Metz. Replaced by ROCKIT. Available at: http://xray.bsd.uchicago.edu/krl/KRL_ROC/software_index.htm.
-
CORROC2. A FORTRAN Program
-
-
Metz, C.1
-
33
-
-
4544361264
-
-
SAS Institute Inc, Cary, NC.
-
PROC MIXED. SAS Institute Inc, Cary, NC. Available at http://www.sas.com
-
PROC MIXED
-
-
-
34
-
-
0031111487
-
Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: Validation wtih computer simulation
-
Roe C.A., Metz C.E. Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data validation wtih computer simulation. Acad Radiol. 4:1997;298-303
-
(1997)
Acad Radiol
, vol.4
, pp. 298-303
-
-
Roe, C.A.1
Metz, C.E.2
-
35
-
-
0347252304
-
A general model for finite-sample effects in training and testing of competing classifiers
-
Beiden S.V., Maloof M., Wagner R.F. A general model for finite-sample effects in training and testing of competing classifiers. IEEE Trans Patt Anal Machine Intell. 25:2003;1561-1569
-
(2003)
IEEE Trans Patt Anal Machine Intell
, vol.25
, pp. 1561-1569
-
-
Beiden, S.V.1
Maloof, M.2
Wagner, R.F.3
-
36
-
-
0033856927
-
Sample size tables for receiver operating characteristic studies
-
Obuchowski N.A. Sample size tables for receiver operating characteristic studies. AJR Am J Roentgenol. 175:2000;603-608
-
(2000)
AJR Am J Roentgenol
, vol.175
, pp. 603-608
-
-
Obuchowski, N.A.1
-
37
-
-
9244261924
-
Power estimation for the Dorfman-Berbaum- Metz method
-
(in press).
-
Hillis SL, Berbaum KS. Power estimation for the Dorfman-Berbaum- Metz method. Acad Radiol (in press).
-
Acad Radiol
-
-
Hillis, S.L.1
Berbaum, K.S.2
|