Volumn 17, Issue 5, 2006, Pages 459-466

Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation

Author keywords

Ablation; Atrial fibrillation; Imaging; Integration

Indexed keywords

ANTIARRHYTHMIC AGENT; GADOLINIUM; IOPAMIDOL;

EID: 33645975865     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2006.00425.x     Document Type: Article
Times cited : (214)

References (21)
  • 4
    • 20444436452 scopus 로고    scopus 로고
    • Technology insight: Catheter ablation of the pulmonary veins in the treatment of atrial fibrillation
    • Dong J Calkins H Technology insight: Catheter ablation of the pulmonary veins in the treatment of atrial fibrillation. Nat Clin Pract Cardiovasc Med 2005 2 159 166.
    • (2005) Nat Clin Pract Cardiovasc Med , vol.2 , pp. 159-166
    • Dong, J.1    Calkins, H.2
  • 7
    • 0029902032 scopus 로고    scopus 로고
    • In vivo accuracy testing and clinical experience with the ISG Viewing Wand
    • discussion 202-204
    • Sipos EP Tebo SA Zinreich SJ Long DM Brem H In vivo accuracy testing and clinical experience with the ISG Viewing Wand. Neurosurgery 1996 39 194 202 discussion 202-204.
    • (1996) Neurosurgery , vol.39 , pp. 194-202
    • Sipos, E.P.1    Tebo, S.A.2    Zinreich, S.J.3    Long, D.M.4    Brem, H.5
  • 8
    • 0034546682 scopus 로고    scopus 로고
    • Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: A comparison of two image registration methods
    • Solomon SB White P Jr.. Wiener CM Orens JB Wang KP Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: A comparison of two image registration methods. Chest 2000 118 1783 1787.
    • (2000) Chest , vol.118 , pp. 1783-1787
    • Solomon, S.B.1    White Jr., P.2    Wiener, C.M.3    Orens, J.B.4    Wang, K.P.5
  • 12
    • 9644265416 scopus 로고    scopus 로고
    • Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation: Feasibility in a porcine model of healed myocardial infarction
    • Reddy VY Malchano ZJ Holmvang G Schmidt EJ d'Avila A Houghtaling C Chan RC Ruskin JN Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation: Feasibility in a porcine model of healed myocardial infarction. J Am Coll Cardiol 2004 44 2202 2213.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2202-2213
    • Reddy, V.Y.1    Malchano, Z.J.2    Holmvang, G.3    Schmidt, E.J.4    D'Avila, A.5    Houghtaling, C.6    Chan, R.C.7    Ruskin, J.N.8
  • 13
    • 19944428236 scopus 로고    scopus 로고
    • Feasibility and validation of registration of three-dimensional left atrial models derived from computed tomography with a noncontact cardiac mapping system
    • Sra J Krum D Hare J Okerlund D Thompson H Vass M Schweitzer J Olson E Foley WD Akhtar M Feasibility and validation of registration of three-dimensional left atrial models derived from computed tomography with a noncontact cardiac mapping system. Heart Rhythm 2005 2 55 63.
    • (2005) Heart Rhythm , vol.2 , pp. 55-63
    • Sra, J.1    Krum, D.2    Hare, J.3    Okerlund, D.4    Thompson, H.5    Vass, M.6    Schweitzer, J.7    Olson, E.8    Foley, W.D.9    Akhtar, M.10
  • 18
    • 19944430314 scopus 로고    scopus 로고
    • Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double Lasso technique
    • Ouyang F Antz M Ernst S Hachiya H Mavrakis H Deger FT Schaumann A Chun J Falk P Hennig D Liu X Bansch D Kuck KH Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double Lasso technique. Circulation 2005 111 127 135.
    • (2005) Circulation , vol.111 , pp. 127-135
    • Ouyang, F.1    Antz, M.2    Ernst, S.3    Hachiya, H.4    Mavrakis, H.5    Deger, F.T.6    Schaumann, A.7    Chun, J.8    Falk, P.9    Hennig, D.10    Liu, X.11    Bansch, D.12    Kuck, K.H.13