메뉴 건너뛰기




Volumn 466, Issue 6, 2008, Pages 1271-1278

Predicting distal femur bone strength in a murine model of tumor osteolysis

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL CELL; ANIMAL EXPERIMENT; ANIMAL MODEL; BIOMECHANICS; BONE DENSITY; BONE RADIOGRAPHY; BONE STRENGTH; COMPUTER ASSISTED TOMOGRAPHY; CONFERENCE PAPER; CONTROLLED STUDY; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FEMUR TUMOR; FINITE ELEMENT ANALYSIS; MICRO-COMPUTED TOMOGRAPHY; MOUSE; NONHUMAN; OSTEOLYSIS; PRIORITY JOURNAL; SCORING SYSTEM; ANIMAL; ARTICLE; COMPRESSIVE STRENGTH; DISEASE MODEL; FEMUR FRACTURE; HOSPITALIZATION; NUDE MOUSE; PATHOPHYSIOLOGY; PHOTON ABSORPTIOMETRY; PHYSIOLOGY; PREDICTION AND FORECASTING; RADIOGRAPHY; WEIGHT BEARING;

EID: 44949168625     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1007/s11999-008-0241-4     Document Type: Conference Paper
Times cited : (17)

References (17)
  • 1
    • 32844465033 scopus 로고    scopus 로고
    • Temporal changes in bone mass and mechanical properties in a murine model of tumor osteolysis
    • Arrington SA, Schoonmaker JE, Damron TA, Mann KA, Allen MJ. Temporal changes in bone mass and mechanical properties in a murine model of tumor osteolysis. Bone. 2006;38:359-367.
    • (2006) Bone , vol.38 , pp. 359-367
    • Arrington, S.A.1    Schoonmaker, J.E.2    Damron, T.A.3    Mann, K.A.4    Allen, M.J.5
  • 3
    • 1842853924 scopus 로고    scopus 로고
    • Failure of trabecular bone with simulated lytic defects can be predicted non-invasively by structural analysis
    • Hong J, Cabe GD, Tedrow JR, Hipp JA, Snyder BD. Failure of trabecular bone with simulated lytic defects can be predicted non-invasively by structural analysis. J Orthop Res. 2004;22:479-486.
    • (2004) J Orthop Res , vol.22 , pp. 479-486
    • Hong, J.1    Cabe, G.D.2    Tedrow, J.R.3    Hipp, J.A.4    Snyder, B.D.5
  • 4
    • 0344157373 scopus 로고    scopus 로고
    • Prediction of femoral fracture load using automated finite element modeling
    • Keyak JH, Rossi SA, Jones KA, Skinner HB. Prediction of femoral fracture load using automated finite element modeling. J Biomech. 1997;31:125-133.
    • (1997) J Biomech , vol.31 , pp. 125-133
    • Keyak, J.H.1    Rossi, S.A.2    Jones, K.A.3    Skinner, H.B.4
  • 7
    • 0035689961 scopus 로고    scopus 로고
    • Prediction of fracture location in the proximal femur using finite element models
    • Keyak JH, Rossi SA, Jones KA, Les CM, Skinner HB. Prediction of fracture location in the proximal femur using finite element models. Med Eng Phys. 2001;23:657-664.
    • (2001) Med Eng Phys , vol.23 , pp. 657-664
    • Keyak, J.H.1    Rossi, S.A.2    Jones, K.A.3    Les, C.M.4    Skinner, H.B.5
  • 8
    • 33947506832 scopus 로고    scopus 로고
    • Predicting failure load of the femur with simulated osteolytic defects using noninvasive imaging technique in a simplified load case
    • Lee T. Predicting failure load of the femur with simulated osteolytic defects using noninvasive imaging technique in a simplified load case. Ann Biomed Eng. 2007;35:642-650.
    • (2007) Ann Biomed Eng , vol.35 , pp. 642-650
    • Lee, T.1
  • 10
    • 0024956668 scopus 로고
    • Metastatic disease in long bones. a proposed scoring system for diagnosing impending pathologic fractures
    • Mirels H. Metastatic disease in long bones. A proposed scoring system for diagnosing impending pathologic fractures. Clin Orthop Relat Res. 1989;249:256-264.
    • (1989) Clin Orthop Relat Res , vol.249 , pp. 256-264
    • Mirels, H.1
  • 11
    • 0030152514 scopus 로고    scopus 로고
    • Curved beam model of the proximal femur for estimating stress using dual-energy X-ray absorptiometry derived structural geometry
    • Mourtada FA, Beck TJ, Hauser DL, Ruff CB, Bao G. Curved beam model of the proximal femur for estimating stress using dual-energy X-ray absorptiometry derived structural geometry. J Orthop Res. 1996;14:483-492.
    • (1996) J Orthop Res , vol.14 , pp. 483-492
    • Mourtada, F.A.1    Beck, T.J.2    Hauser, D.L.3    Ruff, C.B.4    Bao, G.5
  • 12
    • 0033811123 scopus 로고    scopus 로고
    • High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone
    • Niebur GL, Feldstein MJ, Yuen JC, Chen TJ, Keaveny TM. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. J Biomech. 2000;33:1575-1583.
    • (2000) J Biomech , vol.33 , pp. 1575-1583
    • Niebur, G.L.1    Feldstein, M.J.2    Yuen, J.C.3    Chen, T.J.4    Keaveny, T.M.5
  • 14
    • 33751337499 scopus 로고    scopus 로고
    • Comparison of micro-level and continuum-level voxel models of the proximal femur
    • Verhulp E, van Rietbergen B, Huiskes R. Comparison of micro-level and continuum-level voxel models of the proximal femur. J Biomech. 2006;39:2951-2957.
    • (2006) J Biomech , vol.39 , pp. 2951-2957
    • Verhulp, E.1    Van Rietbergen, B.2    Huiskes, R.3
  • 15
    • 0346761904 scopus 로고    scopus 로고
    • Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies
    • Viceconti M, Davinelli M, Taddei F, Cappello A. Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies. J Biomech. 2004;37:1597-1605.
    • (2004) J Biomech , vol.37 , pp. 1597-1605
    • Viceconti, M.1    Davinelli, M.2    Taddei, F.3    Cappello, A.4
  • 16
    • 0037567558 scopus 로고    scopus 로고
    • Blockade of epidermal growth factor receptor signaling leads to inhibition of renal cell carcinoma growth in the bone of nude mice
    • Weber KL, Doucet M, Price JE, Baker C, Kim SJ, Fidler IJ. Blockade of epidermal growth factor receptor signaling leads to inhibition of renal cell carcinoma growth in the bone of nude mice. Cancer Res. 2003;63:2940-2947.
    • (2003) Cancer Res , vol.63 , pp. 2940-2947
    • Weber, K.L.1    Doucet, M.2    Price, J.E.3    Baker, C.4    Kim, S.J.5    Fidler, I.J.6
  • 17
    • 0033818082 scopus 로고    scopus 로고
    • Noninvasive imaging predicts failure load of the spine with simulated osteolytic defects
    • Whealan KM, Kwak SD, Tedrow JR, Inoue K, Snyder BD. Noninvasive imaging predicts failure load of the spine with simulated osteolytic defects. J Bone Joint Surg Am. 2000;82:1240-1251.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1240-1251
    • Whealan, K.M.1    Kwak, S.D.2    Tedrow, J.R.3    Inoue, K.4    Snyder, B.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.