-
1
-
-
2942685521
-
Implant design and interface force transfer a photoelastic and strain-gauge analysis
-
Cehreli M, Duyck J, De Cooman M, et al : Implant design and interface force transfer a photoelastic and strain-gauge analysis. Clin Oral Implants Res 2004 15 : 249 257
-
(2004)
Clin Oral Implants Res
, vol.15
, pp. 249-257
-
-
Cehreli, M.1
Duyck, J.2
De Cooman, M.3
-
2
-
-
0025581284
-
Two-dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution
-
Matsushita Y, Kitoh M, Mizuta K, et al : Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. J Oral Implantol 1990 16 : 6 11
-
(1990)
J Oral Implantol
, vol.16
, pp. 6-11
-
-
Matsushita, Y.1
Kitoh, M.2
Mizuta, K.3
-
3
-
-
0026892027
-
Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible
-
Meijer HJ, Kuiper JH, Starmans FJ, et al : Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent 1992 68 : 96 102
-
(1992)
J Prosthet Dent
, vol.68
, pp. 96-102
-
-
Meijer, H.J.1
Kuiper, J.H.2
Starmans, F.J.3
-
5
-
-
0031986671
-
Evaluating parameters of osseointegrated dental implants using finite element analysis - A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
-
Holmgren EP, Seckinger RJ, Kilgren LM, et al : Evaluating parameters of osseointegrated dental implants using finite element analysis - a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol 1998 24 : 80 88
-
(1998)
J Oral Implantol
, vol.24
, pp. 80-88
-
-
Holmgren, E.P.1
Seckinger, R.J.2
Kilgren, L.M.3
-
6
-
-
0032192923
-
The use of a conical fixture design for fixed partial dentures. a preliminary report
-
Nordin T, Jonsson G, Nelvig P, et al : The use of a conical fixture design for fixed partial dentures. A preliminary report. Clin Oral Implants Res 1998 9 : 343 347
-
(1998)
Clin Oral Implants Res
, vol.9
, pp. 343-347
-
-
Nordin, T.1
Jonsson, G.2
Nelvig, P.3
-
7
-
-
0032039790
-
Marginal bone levels at single tooth implants with a conical fixture design. the influence of surface macro- and microstructure
-
Norton MR : Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure. Clin Oral Implants Res 1998 9 : 91 99
-
(1998)
Clin Oral Implants Res
, vol.9
, pp. 91-99
-
-
Norton, M.R.1
-
8
-
-
19044381224
-
Evaluation of design parameters of osseointegrated dental implants using finite element analysis
-
Chun HJ, Cheong SY, Han JH, et al : Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil 2002 29 : 565 574
-
(2002)
J Oral Rehabil
, vol.29
, pp. 565-574
-
-
Chun, H.J.1
Cheong, S.Y.2
Han, J.H.3
-
9
-
-
0041418181
-
Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
-
Tada S, Stegaroiu R, Kitamura E, et al : Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2003 18 : 357 368
-
(2003)
Int J Oral Maxillofac Implants
, vol.18
, pp. 357-368
-
-
Tada, S.1
Stegaroiu, R.2
Kitamura, E.3
-
10
-
-
0034577012
-
Preliminary evaluation of a new dental implant design in canine models
-
Bumgardner JD, Boring JG, Cooper RC Jr., et al : Preliminary evaluation of a new dental implant design in canine models. Implant Dent 2000 9 : 252 260
-
(2000)
Implant Dent
, vol.9
, pp. 252-260
-
-
Bumgardner, J.D.1
Boring, J.G.2
Cooper Jr., R.C.3
-
12
-
-
0036134211
-
Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone
-
Iplikcioglu H, Akca K : Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. J Dent 2002 30 : 41 46
-
(2002)
J Dent
, vol.30
, pp. 41-46
-
-
Iplikcioglu, H.1
Akca, K.2
-
15
-
-
0002172340
-
Patient selection and preparation
-
In: Branemark, P.I., Zarb, G.A., Albrektsson, T. (. eds. Chicago, IL, Quintessence, pp.
-
Lekholm U, Zarb GA : Patient selection and preparation. In : Branemark PI, Zarb GA, Albrektsson T (eds Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Chicago, IL, Quintessence, 1985, pp. 199 209
-
(1985)
Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry.
, pp. 199-209
-
-
Lekholm, U.1
Zarb, G.A.2
-
16
-
-
4644291445
-
Biomechanical aspects of marginal bone resorption around osseointegrated implants: Considerations based on a three-dimensional finite element analysis
-
Kitamura E, Stegaroiu R, Nomura S, et al : Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Impl Res 2004 15 : 401 412
-
(2004)
Clin Oral Impl Res
, vol.15
, pp. 401-412
-
-
Kitamura, E.1
Stegaroiu, R.2
Nomura, S.3
-
17
-
-
16344386568
-
Influence of marginal bone resorption on stress around an implant - A three-dimensional finite element analysis
-
Kitamura E, Stegaroiu R, Nomura S, et al : Influence of marginal bone resorption on stress around an implant - a three-dimensional finite element analysis. J Oral Rehabil 2005 32 : 279 286
-
(2005)
J Oral Rehabil
, vol.32
, pp. 279-286
-
-
Kitamura, E.1
Stegaroiu, R.2
Nomura, S.3
-
18
-
-
0026298340
-
Three-dimensional analyses of human bite-force magnitude and moment
-
van Eijden TM : Three-dimensional analyses of human bite-force magnitude and moment. Arch Oral Biol 1991 36 : 535 539
-
(1991)
Arch Oral Biol
, vol.36
, pp. 535-539
-
-
Van Eijden, T.M.1
-
19
-
-
0026218667
-
Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
-
Jemt T : Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991 6 : 270 276
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, pp. 270-276
-
-
Jemt, T.1
-
20
-
-
0024675462
-
Bone resorption at the entry of osseointegrated implants - A biomechanical phenomenon. Finite element study [in German]
-
Mailath G, Stoiber B, Watzek G, et al : Bone resorption at the entry of osseointegrated implants - a biomechanical phenomenon. Finite element study [in German]. Z Stomatol 1989 86 : 207 216
-
(1989)
Z Stomatol
, vol.86
, pp. 207-216
-
-
Mailath, G.1
Stoiber, B.2
Watzek, G.3
-
21
-
-
0025581284
-
Two-dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution
-
Matsushita Y, Kitoh M, Mizuta K, et al : Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. J Oral Implantol 1990 16 : 6 11
-
(1990)
J Oral Implantol
, vol.16
, pp. 6-11
-
-
Matsushita, Y.1
Kitoh, M.2
Mizuta, K.3
-
22
-
-
0346207585
-
Influence of variations in implants diameters: A 3- to 5-year retrospective clinical report
-
Ivanoff CJ, Grondahl K, Sennerby L, et al : Influence of variations in implants diameters: a 3- to 5-year retrospective clinical report. Int J Oral Maxillofac Implants 1999 14 : 173 180
-
(1999)
Int J Oral Maxillofac Implants
, vol.14
, pp. 173-180
-
-
Ivanoff, C.J.1
Grondahl, K.2
Sennerby, L.3
-
23
-
-
0032617146
-
Five-mm-diameter implants without a smooth surface collar: Report on 98 consecutive placements
-
Renouard F, Arnoux JP, Sarment DP : Five-mm-diameter implants without a smooth surface collar: report on 98 consecutive placements. Int J Oral Maxillofac Implants 1999 14 : 101 107
-
(1999)
Int J Oral Maxillofac Implants
, vol.14
, pp. 101-107
-
-
Renouard, F.1
Arnoux, J.P.2
Sarment, D.P.3
-
24
-
-
26944455656
-
Comparative evaluation of implant designs: Influence of diameter, length, and taper on strains in the alveolar crest. a three-dimensional finite-element analysis
-
Petrie CS, Williams JL : Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis. Clin Oral Implants Res 2005 16 : 486 494
-
(2005)
Clin Oral Implants Res
, vol.16
, pp. 486-494
-
-
Petrie, C.S.1
Williams, J.L.2
-
25
-
-
0026892027
-
Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible
-
Meijer HJ, Kuiper JH, Starmans FJM, et al : Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent 1992 68 : 92 102
-
(1992)
J Prosthet Dent
, vol.68
, pp. 92-102
-
-
Meijer, H.J.1
Kuiper, J.H.2
Starmans, F.J.M.3
-
26
-
-
44949149331
-
Bending overload and implant fracture: A retrospective clinical analysis
-
Rangert B, Krogh PH, Langer B, et al : Bending overload and implant fracture: a retrospective clinical analysis. Int J Oral Maxillofac Implants 1996 11 : 575
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 575
-
-
Rangert, B.1
Krogh, P.H.2
Langer, B.3
-
27
-
-
0020173242
-
A model for the implant-bone interface characteristics of porous dental implants
-
Cook SD, Klawitter JJ, Weinstein AM : A model for the implant-bone interface characteristics of porous dental implants. J Dent Res 1982 61 : 1006 1009
-
(1982)
J Dent Res
, vol.61
, pp. 1006-1009
-
-
Cook, S.D.1
Klawitter, J.J.2
Weinstein, A.M.3
-
28
-
-
0020711801
-
Three-dimensional stress distribution around a dental implant at different stages of interface development
-
Borchers L, Reichart P : Three-dimensional stress distribution around a dental implant at different stages of interface development. J Dent Res 1983 62 : 155 159
-
(1983)
J Dent Res
, vol.62
, pp. 155-159
-
-
Borchers, L.1
Reichart, P.2
-
30
-
-
0029303148
-
Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis
-
Lewinstein I, Banks-Sills L, Eliasi R : Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis. Int J Oral Maxillofac Implants 1995 10 : 355 366
-
(1995)
Int J Oral Maxillofac Implants
, vol.10
, pp. 355-366
-
-
Lewinstein, I.1
Banks-Sills, L.2
Eliasi, R.3
|