메뉴 건너뛰기




Volumn 37, Issue 6, 2008, Pages 694-699

Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and orbicularis oculi muscles

Author keywords

Concentric needle electrode; Extensor digitorum communis; Jitter; Orbicularis oculi; Single fiber electromyography

Indexed keywords

ADULT; ARTICLE; BRAZIL; ELECTROMYOGRAM; ELECTROMYOGRAPHY; EXTENSOR DIGITORUM COMMUNIS; FEMALE; HAND MUSCLE; HUMAN; HUMAN EXPERIMENT; MALE; MUSCLE CELL; MUSCLE CONTRACTION; NEUROMUSCULAR JITTER; NORMAL HUMAN; ORBICULARIS OCULI MUSCLE; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RELIABILITY; SKIN ELECTRODE; VOLUNTARY MOVEMENT;

EID: 44949142964     PISSN: 0148639X     EISSN: 10974598     Source Type: Journal    
DOI: 10.1002/mus.21043     Document Type: Article
Times cited : (66)

References (21)
  • 1
    • 0034888044 scopus 로고    scopus 로고
    • Literature review of the usefulness of repetitive nerve stimulation and single fiber EMG in the electrodiagnostic evaluation of patients with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome
    • AAEM Quality Assurance Committee
    • AAEM Quality Assurance Committee. Literature review of the usefulness of repetitive nerve stimulation and single fiber EMG in the electrodiagnostic evaluation of patients with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome. Muscle Nerve 2001;24:1239-1247.
    • (2001) Muscle Nerve , vol.24 , pp. 1239-1247
  • 2
    • 0034887749 scopus 로고    scopus 로고
    • Practice parameter for repetitive nerve stimulation and single fiber EMG evaluation of adults with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome: Summary statement
    • AAEM Quality Assurance Committee
    • AAEM Quality Assurance Committee. Practice parameter for repetitive nerve stimulation and single fiber EMG evaluation of adults with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome: summary statement. Muscle Nerve 2001;24:1236-1238.
    • (2001) Muscle Nerve , vol.24 , pp. 1236-1238
  • 3
    • 33746266452 scopus 로고    scopus 로고
    • Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis
    • Benatar M, Hammad M, Doss-Riney H. Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis. Muscle Nerve 2006;34:163-168.
    • (2006) Muscle Nerve , vol.34 , pp. 163-168
    • Benatar, M.1    Hammad, M.2    Doss-Riney, H.3
  • 4
    • 0028352202 scopus 로고
    • Single fiber EMG reference values: Reformatted in tabular form. Ad Hoc Committee of the AAEM Single Fiber Special Interest Group
    • Bromberg MB, Scott DM. Single fiber EMG reference values: reformatted in tabular form. Ad Hoc Committee of the AAEM Single Fiber Special Interest Group. Muscle Nerve 1994;17:820-821.
    • (1994) Muscle Nerve , vol.17 , pp. 820-821
    • Bromberg, M.B.1    Scott, D.M.2
  • 5
    • 0026548714 scopus 로고
    • Determining neuromuscular jitter using a monopolar electrode
    • Buchman AS, Garratt M. Determining neuromuscular jitter using a monopolar electrode. Muscle Nerve 1992;15:615-19.
    • (1992) Muscle Nerve , vol.15 , pp. 615-619
    • Buchman, A.S.1    Garratt, M.2
  • 7
    • 0015712801 scopus 로고
    • How the size of the needle electrode leading-off surface influences the shape of the single muscle fibre action potentials in electromyography
    • Ekstedt J, Stålberg E. How the size of the needle electrode leading-off surface influences the shape of the single muscle fibre action potentials in electromyography. Comput Progr Biomed 1973;3:204-212.
    • (1973) Comput Progr Biomed , vol.3 , pp. 204-212
    • Ekstedt, J.1    Stålberg, E.2
  • 8
    • 0002559023 scopus 로고
    • Human single muscle fiber action potentials
    • Ekstedt J. Human single muscle fiber action potentials. Acta Neurol Scand 1964;61:1-96.
    • (1964) Acta Neurol Scand , vol.61 , pp. 1-96
    • Ekstedt, J.1
  • 10
    • 0026565353 scopus 로고
    • Hoc Committee of the AAEM interest group on single fiber EMG. Single fiber EMG reference values: A collaborative effort
    • Gilchrist JM. Ad Hoc Committee of the AAEM interest group on single fiber EMG. Single fiber EMG reference values: a collaborative effort. Muscle Nerve 1992;15:151-161.
    • (1992) Muscle Nerve , vol.15 , pp. 151-161
    • Gilchrist, J.A.1
  • 11
    • 34547644081 scopus 로고    scopus 로고
    • Concentric needle single fiber electromyography: Normative jitter values on voluntary activated extensor digitorum communis
    • Kouyoumdjian JA, Stålberg EV. Concentric needle single fiber electromyography: normative jitter values on voluntary activated extensor digitorum communis. Arq Neuropsiquiatr 2007;65:446-449.
    • (2007) Arq Neuropsiquiatr , vol.65 , pp. 446-449
    • Kouyoumdjian, J.A.1    Stålberg, E.V.2
  • 12
    • 44949137140 scopus 로고    scopus 로고
    • Concentric needle single fiber electromyography: Comparative jitter on voluntary-activated and stimulated extensor digitorum communis
    • in press
    • Kouyoumdjian JA, Stålberg EV. Concentric needle single fiber electromyography: comparative jitter on voluntary-activated and stimulated extensor digitorum communis. Clin Neurophysiol (in press).
    • Clin Neurophysiol
    • Kouyoumdjian, J.A.1    Stålberg, E.V.2
  • 13
    • 0018123869 scopus 로고
    • The blanket principle: A technical note
    • Payan J. The blanket principle: a technical note. Muscle Nerve 1978;1:423-426.
    • (1978) Muscle Nerve , vol.1 , pp. 423-426
    • Payan, J.1
  • 14
    • 0029791610 scopus 로고    scopus 로고
    • AAEM minimonograph #25: Single-fiber electromyography
    • Sanders DB, Stålberg EV. AAEM minimonograph #25: Single-fiber electromyography. Muscle Nerve 1996;19:1069-1083.
    • (1996) Muscle Nerve , vol.19 , pp. 1069-1083
    • Sanders, D.B.1    Stålberg, E.V.2
  • 15
    • 0036263304 scopus 로고    scopus 로고
    • Clinical impact of single-fiber electromyography
    • Sanders DB. Clinical impact of single-fiber electromyography. Muscle Nerve 2002;11(suppl):S15-S20.
    • (2002) Muscle Nerve , vol.11 , Issue.SUPPL.
    • Sanders, D.B.1
  • 16
    • 30344468443 scopus 로고    scopus 로고
    • Single-fiber EMG with a concentric needle electrode: Validation in myasthenia gravis
    • Sarrigiannis PG, Kennett RP, Read S, Farrugia ME. Single-fiber EMG with a concentric needle electrode: validation in myasthenia gravis. Muscle Nerve 2006;33:61-65.
    • (2006) Muscle Nerve , vol.33 , pp. 61-65
    • Sarrigiannis, P.G.1    Kennett, R.P.2    Read, S.3    Farrugia, M.E.4
  • 18
    • 0027991039 scopus 로고
    • Assessment of variability in the shape of the motor unit action potential, the "jiggle," at consecutive discharges
    • Stålberg E, Sonoo M. Assessment of variability in the shape of the motor unit action potential, the "jiggle," at consecutive discharges. Muscle Nerve 1994;17:1135-1144.
    • (1994) Muscle Nerve , vol.17 , pp. 1135-1144
    • Stålberg, E.1    Sonoo, M.2
  • 21
    • 0026599212 scopus 로고
    • Jitter measurement by axonal microstimulation. Guidelines and technical notes
    • Trontelj JV, Stålberg E. Jitter measurement by axonal microstimulation. Guidelines and technical notes. Electroencephalogr Clin Neurophysiol 1992;85:30-37.
    • (1992) Electroencephalogr Clin Neurophysiol , vol.85 , pp. 30-37
    • Trontelj, J.V.1    Stålberg, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.