메뉴 건너뛰기




Volumn 65, Issue 2 B, 2007, Pages 446-449

Concentric needle single fiber electromyography: Normative jitter values on voluntary activated Extensor Digitorum Communis

Author keywords

Concentric needle electrode; Jitter; Single fiber electromyography

Indexed keywords

ADULT; ARTICLE; CONCENTRIC NEEDLE ELECTRODE; ELECTROMYOGRAPHY; FEMALE; HUMAN; HUMAN EXPERIMENT; MALE; MEASUREMENT; MUSCLE ACTION POTENTIAL; MUSCLE CELL; MYASTHENIA GRAVIS; NEEDLE; NEUROMUSCULAR JUNCTION DISORDER; NEUROPHYSIOLOGY; NORMAL HUMAN; PROSPECTIVE STUDY; SAFETY; SINGLE FIBER ELECTROMYOGRAPHY; VOLUNTARY MOVEMENT;

EID: 34547644081     PISSN: 0004282X     EISSN: 16784227     Source Type: Journal    
DOI: 10.1590/S0004-282X2007000300016     Document Type: Article
Times cited : (33)

References (13)
  • 1
    • 0002559023 scopus 로고
    • Human single muscle fiber action potentials
    • Ekstedt J. Human single muscle fiber action potentials. Acta Neurol Scand 1964;61:1-696.
    • (1964) Acta Neurol Scand , vol.61 , pp. 1-696
    • Ekstedt, J.1
  • 2
    • 0029791610 scopus 로고    scopus 로고
    • AAEM minimonograph #25: Single-fiber electromyography
    • Sanders DG, Stålberg EV. AAEM minimonograph #25: single-fiber electromyography. Muscle Nerve 1996;19:1069-1083.
    • (1996) Muscle Nerve , vol.19 , pp. 1069-1083
    • Sanders, D.G.1    Stålberg, E.V.2
  • 4
    • 0028352202 scopus 로고
    • Single fiber EMG reference values: Reformatted in tabular form. Ad Hoc Committee of the AAEM Single Fiber Special Interest Group
    • Bromberg MB, Scott DM. Single fiber EMG reference values: reformatted in tabular form. Ad Hoc Committee of the AAEM Single Fiber Special Interest Group. Muscle Nerve 1994;17:820-821.
    • (1994) Muscle Nerve , vol.17 , pp. 820-821
    • Bromberg, M.B.1    Scott, D.M.2
  • 5
    • 0034887749 scopus 로고    scopus 로고
    • Practice parameter for repetitive nerve stimulation and single fiber EMG evaluation of adults with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome: Summary statement
    • AAEM Quality Assurance Committee
    • AAEM Quality Assurance Committee. Practice parameter for repetitive nerve stimulation and single fiber EMG evaluation of adults with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome: summary statement. Muscle Nerve 2001;24:1236-1238.
    • (2001) Muscle Nerve , vol.24 , pp. 1236-1238
  • 6
    • 0034888044 scopus 로고    scopus 로고
    • AAEM Quality Assurance Cornmittee. Literature review of the usefulness of repetitive nerve stimulation and single fiber EMG in the electrodiagnostic evaluation of patients with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome
    • AAEM Quality Assurance Cornmittee. Literature review of the usefulness of repetitive nerve stimulation and single fiber EMG in the electrodiagnostic evaluation of patients with suspected myasthenia gravis or Lambert-Eaton myasthenic syndrome. Muscle Nerve 2001;24:1239-1247.
    • (2001) Muscle Nerve , vol.24 , pp. 1239-1247
  • 7
    • 0026565353 scopus 로고
    • Hoc Committee of the AAEM interest group on single fiber EMG. Single fiber EMG reference values: A collaborative effort
    • Gilchrist JM. Ad Hoc Committee of the AAEM interest group on single fiber EMG. Single fiber EMG reference values: a collaborative effort. Muscle Nerve 1992;15:151-161.
    • (1992) Muscle Nerve , vol.15 , pp. 151-161
    • Gilchrist, J.A.1
  • 8
    • 0034064192 scopus 로고    scopus 로고
    • Erta M, Bari BasloM, YildizN, Yazici J, Emre Öge A. Concentric needle electrode for neuromuscular jitter analysis. Muscle Nerve 2000;23:715-719.
    • Erta M, Bari BasloM, YildizN, Yazici J, Emre Öge A. Concentric needle electrode for neuromuscular jitter analysis. Muscle Nerve 2000;23:715-719.
  • 9
    • 0036263304 scopus 로고    scopus 로고
    • Clinical impact of single-fiber electromyography
    • Sanders DB. Clinical impact of single-fiber electromyography. Muscle Nerve 2002;11 (Suppl):15-20.
    • (2002) Muscle Nerve , vol.11 , Issue.SUPPL. , pp. 15-20
    • Sanders, D.B.1
  • 10
    • 33746266452 scopus 로고    scopus 로고
    • Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis
    • Benatar M, Hammad M, Doss-Riney H. Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis. Muscle Nerve 2006;34:163-168.
    • (2006) Muscle Nerve , vol.34 , pp. 163-168
    • Benatar, M.1    Hammad, M.2    Doss-Riney, H.3
  • 11
    • 30344468443 scopus 로고    scopus 로고
    • Single-fiber EMG with a concentric needle electrode: Validation in myasthenia gravis
    • Sarrigiannis PG, Kennett RP, Read S, Farrugia ME. Single-fiber EMG with a concentric needle electrode: validation in myasthenia gravis. Muscle Nerve 2006;33:61-65.
    • (2006) Muscle Nerve , vol.33 , pp. 61-65
    • Sarrigiannis, P.G.1    Kennett, R.P.2    Read, S.3    Farrugia, M.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.