메뉴 건너뛰기




Volumn 55, Issue 6, 2008, Pages 1267-1276

Development of a method for ultrasound-guided placement of pedicle screws

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC WAVES; ALUMINUM; BONE; ELECTRONIC GUIDANCE SYSTEMS; FASTENERS; LIGHT METALS; MICROFLUIDICS; SCREWS; TISSUE; ULTRASONIC APPLICATIONS; ULTRASONIC TRANSMISSION; ULTRASONICS;

EID: 44949092266     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2008.789     Document Type: Article
Times cited : (29)

References (48)
  • 1
    • 44949108522 scopus 로고    scopus 로고
    • accessed May 2007
    • United States Department of Health & Human Services, "Agency for healthcare research and quality," http://hcupnet.ahrq.gov/, (accessed May 2007).
  • 2
    • 33750537850 scopus 로고    scopus 로고
    • Cervical pedicle screws vs. lateral mass screws: Uniplanar fatigue analysis and residual pullout strength
    • Nov
    • T. L. Johnson, E. E. Karaikovic, E. P. Lautenschlager, and D. Marcu, "Cervical pedicle screws vs. lateral mass screws: Uniplanar fatigue analysis and residual pullout strength," Spine J., vol. 6, pp. 667-672, Nov. 2006.
    • (2006) Spine J , vol.6 , pp. 667-672
    • Johnson, T.L.1    Karaikovic, E.E.2    Lautenschlager, E.P.3    Marcu, D.4
  • 4
    • 44949102577 scopus 로고    scopus 로고
    • Thoracic pedicle screws
    • T. R. Haher and A. A. Merola, Eds. New York: Thieme Medical
    • A. H. von Strempel, "Thoracic pedicle screws," in Surgical Techniques of the Spine. T. R. Haher and A. A. Merola, Eds. New York: Thieme Medical, 2004, pp. 86-90.
    • (2004) Surgical Techniques of the Spine , pp. 86-90
    • von Strempel, A.H.1
  • 5
    • 34548236591 scopus 로고    scopus 로고
    • Thoracic pedicle screw placement
    • A. R. Vaccaro and T. J. Albert, Eds. New York: Thieme Medical
    • C. G. Fisher, "Thoracic pedicle screw placement," in Spine Surgery: Tricks of the Trade. A. R. Vaccaro and T. J. Albert, Eds. New York: Thieme Medical, 2003, pp. 90-91.
    • (2003) Spine Surgery: Tricks of the Trade , pp. 90-91
    • Fisher, C.G.1
  • 6
    • 44949213184 scopus 로고    scopus 로고
    • Lumbar pedicle fixation
    • T. R. Haher and A. A. Merola, Eds. New York: Thieme Medical
    • V. J. Devlin and M. A. Asher, "Lumbar pedicle fixation," in Surgical Techniques of the Spine. T. R. Haher and A. A. Merola, Eds. New York: Thieme Medical, 2004, pp. 212-217.
    • (2004) Surgical Techniques of the Spine , pp. 212-217
    • Devlin, V.J.1    Asher, M.A.2
  • 7
    • 44949182147 scopus 로고    scopus 로고
    • Lumbar pedicle screw placement
    • A. R. Vaccaro and T. J. Albert, Eds. New York: Thieme Medical
    • E. Truumees, "Lumbar pedicle screw placement," in Spine Surgery: Tricks of the Trade. A. R. Vaccaro and T. J. Albert, Eds. New York: Thieme Medical, 2003, pp. 156-157.
    • (2003) Spine Surgery: Tricks of the Trade , pp. 156-157
    • Truumees, E.1
  • 8
    • 15944393250 scopus 로고    scopus 로고
    • Transpedicular screw fixation of the lumbar spine: Review and technique
    • Jan
    • R. S. Rabinowitz and B. L. Currier, "Transpedicular screw fixation of the lumbar spine: Review and technique," Oper. Tech. Orthop., vol. 7, pp. 71-78, Jan. 1997.
    • (1997) Oper. Tech. Orthop , vol.7 , pp. 71-78
    • Rabinowitz, R.S.1    Currier, B.L.2
  • 11
    • 0035260780 scopus 로고    scopus 로고
    • Lumbar pedicle: Surgical anatomic evaluation and relationships
    • Mar
    • A. Attar, H. C. Ugur, A. Uz, I. Tekdemir, N. Egemen, and Y. Genc, "Lumbar pedicle: Surgical anatomic evaluation and relationships," Eur. Spine J., vol. 10, pp. 10-15, Mar. 2001.
    • (2001) Eur. Spine J , vol.10 , pp. 10-15
    • Attar, A.1    Ugur, H.C.2    Uz, A.3    Tekdemir, I.4    Egemen, N.5    Genc, Y.6
  • 12
    • 0034985208 scopus 로고    scopus 로고
    • Vertebral pedicle anatomy in relation to pedicle screw fixation: A cadaver study
    • June
    • P. Chaynes, J.-C. Sol, P. Vaysee, J. Becue, and J. Lagarrigue, "Vertebral pedicle anatomy in relation to pedicle screw fixation: A cadaver study," Surg. Radiol. Anat., vol. 23, pp. 85-90, June 2001.
    • (2001) Surg. Radiol. Anat , vol.23 , pp. 85-90
    • Chaynes, P.1    Sol, J.-C.2    Vaysee, P.3    Becue, J.4    Lagarrigue, J.5
  • 13
    • 44949211628 scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomized controlled clinical study in 100 consecutive patients
    • Nov
    • T. Laine, T. Lund, M. Ylikoski, J. Lohikoski, and D. Schlenzka, "Accuracy of pedicle screw insertion with and without computer assistance: A randomized controlled clinical study in 100 consecutive patients," Eur. Spine J., vol. 9, pp. 344-361, Nov. 1910.
    • (1910) Eur. Spine J , vol.9 , pp. 344-361
    • Laine, T.1    Lund, T.2    Ylikoski, M.3    Lohikoski, J.4    Schlenzka, D.5
  • 14
    • 4544343101 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in thoracic spine fractures: Part I: Inter- and intraob-server reliability of the scoring system
    • Aug
    • M. Zdichavsky, M. Blauth, C. Knop, M. Graessner, H. Herrmann, C. Krettek, and L. Bastian, "Accuracy of pedicle screw placement in thoracic spine fractures: Part I: Inter- and intraob-server reliability of the scoring system," Eur. J. Trauma, vol. 30, pp. 234-240, Aug. 2004.
    • (2004) Eur. J. Trauma , vol.30 , pp. 234-240
    • Zdichavsky, M.1    Blauth, M.2    Knop, C.3    Graessner, M.4    Herrmann, H.5    Krettek, C.6    Bastian, L.7
  • 15
    • 4544345056 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in thoracic spine fractures: Part II: A retrospective analysis of 278 pedicle screws suing computer tomography scans
    • Aug
    • M. Zdichavsky, C. Knop, M. Blauth, J. Lotz, C. Krettek, and L. Bastian, "Accuracy of pedicle screw placement in thoracic spine fractures: Part II: A retrospective analysis of 278 pedicle screws suing computer tomography scans," Eur. J. Trauma, vol. 30, pp. 241-247, Aug. 2004.
    • (2004) Eur. J. Trauma , vol.30 , pp. 241-247
    • Zdichavsky, M.1    Knop, C.2    Blauth, M.3    Lotz, J.4    Krettek, C.5    Bastian, L.6
  • 16
    • 0035500223 scopus 로고    scopus 로고
    • In vivo accuracy of thoracic pedicle screws
    • Nov
    • P. J. Belmont, W. R. Klemme, A. Dhawan, and D. W. Polly, "In vivo accuracy of thoracic pedicle screws," Spine, vol. 26, pp. 2340-2346, Nov. 2001.
    • (2001) Spine , vol.26 , pp. 2340-2346
    • Belmont, P.J.1    Klemme, W.R.2    Dhawan, A.3    Polly, D.W.4
  • 17
    • 1442277695 scopus 로고    scopus 로고
    • Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
    • Feb
    • M. Richter, T. Mattes, and B. Cakir, "Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine," Eur. Spine J., vol. 13, pp. 50-59, Feb. 2004.
    • (2004) Eur. Spine J , vol.13 , pp. 50-59
    • Richter, M.1    Mattes, T.2    Cakir, B.3
  • 18
    • 0002660907 scopus 로고    scopus 로고
    • Computer-assisted spine surgery
    • Feb
    • D. Schlenzka, T. Laine, and T. Lund, "Computer-assisted spine surgery," Eur. Spine J., vol. 9, Suppl. 1, pp. 57S-64S, Feb. 2000.
    • (2000) Eur. Spine J , vol.9 , Issue.SUPPL. 1
    • Schlenzka, D.1    Laine, T.2    Lund, T.3
  • 19
    • 0037401152 scopus 로고    scopus 로고
    • Computer assisted orthopaedic and trauma surgery: State of the art and future perspectives
    • May
    • N. W. L. Schep, I. A. M. J. Broeders, and C. van der Werken, "Computer assisted orthopaedic and trauma surgery: State of the art and future perspectives," Injury, vol. 34, pp. 299-306, May 2003.
    • (2003) Injury , vol.34 , pp. 299-306
    • Schep, N.W.L.1    Broeders, I.A.M.J.2    van der Werken, C.3
  • 20
    • 3042805099 scopus 로고    scopus 로고
    • Navigation using fluoro-CT technology: Concept and clinical experience in a new method for intra-operative navigation
    • June
    • P. A. Gruetzner, H. Waelti, B. Vock, A. Hebecker, L.-P. Nolte, and A. Wentzensen, "Navigation using fluoro-CT technology: Concept and clinical experience in a new method for intra-operative navigation," Eur. J. Trauma, vol. 30, pp. 161-171, June 2004.
    • (2004) Eur. J. Trauma , vol.30 , pp. 161-171
    • Gruetzner, P.A.1    Waelti, H.2    Vock, B.3    Hebecker, A.4    Nolte, L.-P.5    Wentzensen, A.6
  • 22
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion: Fluo-roscopic method versus computer assisted surgery
    • May
    • M. Slomczykowski, M. Roberto, P. Schneeberger, C. Ozdoba, and P. Vock, "Radiation dose for pedicle screw insertion: Fluo-roscopic method versus computer assisted surgery," Spine, vol. 24, pp. 975-983, May 1999.
    • (1999) Spine , vol.24 , pp. 975-983
    • Slomczykowski, M.1    Roberto, M.2    Schneeberger, P.3    Ozdoba, C.4    Vock, P.5
  • 23
    • 0034667336 scopus 로고    scopus 로고
    • Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
    • Oct
    • Y. R. Rampersaud, K. T. Foley, A. C. Shen, S. Williams, and M. Solomito, "Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion," Spine, vol. 25, pp. 2637-2645, Oct. 2000.
    • (2000) Spine , vol.25 , pp. 2637-2645
    • Rampersaud, Y.R.1    Foley, K.T.2    Shen, A.C.3    Williams, S.4    Solomito, M.5
  • 24
    • 0028243126 scopus 로고
    • The dependence of ultrasonic properties on orientation in human vertebral bone
    • June
    • P. H. F. Nicholson, M. J. Haddaway, and M. W. J. Davie, "The dependence of ultrasonic properties on orientation in human vertebral bone," Phys. Med. Biol., vol. 39, no. 6, pp. 1013-1024, June 1994.
    • (1994) Phys. Med. Biol , vol.39 , Issue.6 , pp. 1013-1024
    • Nicholson, P.H.F.1    Haddaway, M.J.2    Davie, M.W.J.3
  • 28
    • 0024999279 scopus 로고
    • Reflection and transmission of elastic waves from a fluid-saturated porous solid boundary
    • June
    • K. Wu, Q. Xue, and L. Alder, "Reflection and transmission of elastic waves from a fluid-saturated porous solid boundary," J. Acoust. Soc. Amer., vol. 87, pp. 2349-2358, June 1990.
    • (1990) J. Acoust. Soc. Amer , vol.87 , pp. 2349-2358
    • Wu, K.1    Xue, Q.2    Alder, L.3
  • 29
    • 0033813008 scopus 로고    scopus 로고
    • In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz
    • Sep
    • S. Chaffai, F. Padilla, G. Berger, and P. Laugier, "In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz," J. Acoust. Soc. Amer., vol. 108, pp. 1281-1289, Sep. 2000.
    • (2000) J. Acoust. Soc. Amer , vol.108 , pp. 1281-1289
    • Chaffai, S.1    Padilla, F.2    Berger, G.3    Laugier, P.4
  • 30
    • 0018005102 scopus 로고
    • On the determination of phase and group velocities of dispersive waves in solids
    • Aug
    • W. Sachse and Y.-H. Pao, "On the determination of phase and group velocities of dispersive waves in solids," J. Appl. Phys., vol. 49, pp. 4320-4327, Aug. 1978.
    • (1978) J. Appl. Phys , vol.49 , pp. 4320-4327
    • Sachse, W.1    Pao, Y.-H.2
  • 31
    • 0029907932 scopus 로고    scopus 로고
    • A comparison of time-domain and frequency-domain approaches to ultrasonic velocity measurement in trabecular bone
    • Nov
    • P. H. F. Nicholson, G. Lowet, C. M. Langton, J. Dequeker, and G. Van der Perre, "A comparison of time-domain and frequency-domain approaches to ultrasonic velocity measurement in trabecular bone," Phys. Med. Biol., vol. 41, pp. 2421-2435, Nov. 1996.
    • (1996) Phys. Med. Biol , vol.41 , pp. 2421-2435
    • Nicholson, P.H.F.1    Lowet, G.2    Langton, C.M.3    Dequeker, J.4    Van der Perre, G.5
  • 32
    • 0022268239 scopus 로고
    • Diffraction and dispersion effects on the estimation of ultrasound attenuation and velocity in biological tissues
    • July
    • W. A. Verhoef, M. J. T. M. Cloostermans, and J. M. Thijssen, "Diffraction and dispersion effects on the estimation of ultrasound attenuation and velocity in biological tissues," IEEE Trans. Biomed. Eng., vol. 7, pp. 521-529, July 1985.
    • (1985) IEEE Trans. Biomed. Eng , vol.7 , pp. 521-529
    • Verhoef, W.A.1    Cloostermans, M.J.T.M.2    Thijssen, J.M.3
  • 34
    • 0035263392 scopus 로고    scopus 로고
    • Ultrasonic attenuation in human calcaneous from 0.2 to 1.7 MHz
    • Mar
    • K. A. Wear, "Ultrasonic attenuation in human calcaneous from 0.2 to 1.7 MHz," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 48, pp. 602-608, Mar. 2001.
    • (2001) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.48 , pp. 602-608
    • Wear, K.A.1
  • 35
    • 0031081116 scopus 로고    scopus 로고
    • In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography
    • Feb
    • P. Laugier, P. Droin, A. M. Laval-Jeantet, and G. Berger, "In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography," Bone, vol. 20, pp. 157-165, Feb. 1997.
    • (1997) Bone , vol.20 , pp. 157-165
    • Laugier, P.1    Droin, P.2    Laval-Jeantet, A.M.3    Berger, G.4
  • 36
    • 0034131128 scopus 로고    scopus 로고
    • Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: Implications for relative roles of absorption and scattering in determining attenuation
    • June
    • K. A. Wear, "Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: Implications for relative roles of absorption and scattering in determining attenuation," J. Acoust. Soc. Amer., vol. 107, pp. 3474-3479, June 2000.
    • (2000) J. Acoust. Soc. Amer , vol.107 , pp. 3474-3479
    • Wear, K.A.1
  • 37
    • 0030248363 scopus 로고    scopus 로고
    • Combined models of ultrasound velocity and attenuation for predicting trabecular bone strength and mineral density
    • Sep
    • S. Han, J. Medige, and I. Ziv, "Combined models of ultrasound velocity and attenuation for predicting trabecular bone strength and mineral density," Clin. Biomech., vol. 11, pp. 348-353, Sep. 1996.
    • (1996) Clin. Biomech , vol.11 , pp. 348-353
    • Han, S.1    Medige, J.2    Ziv, I.3
  • 38
    • 30844447444 scopus 로고    scopus 로고
    • In vitro ultrasonic characterization of human can-cellous femoral bone using transmission and backscatter measurements: Relationship to bone mineral density
    • Jan
    • F. Jenson, F. Padilla, V. Bousson, C. Bergot, J.-D. Laredo, and P. Laugier, "In vitro ultrasonic characterization of human can-cellous femoral bone using transmission and backscatter measurements: Relationship to bone mineral density," J. Acoust. Soc. Amer., vol. 119, pp. 654-663, Jan. 2006.
    • (2006) J. Acoust. Soc. Amer , vol.119 , pp. 654-663
    • Jenson, F.1    Padilla, F.2    Bousson, V.3    Bergot, C.4    Laredo, J.-D.5    Laugier, P.6
  • 39
    • 0036140389 scopus 로고    scopus 로고
    • Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: Relationships to density and microstructure
    • Jan
    • S. Chaffai, F. Peyrin, S. Nuzzo, R. Porcher, G. Berger, and P. Laugier, "Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: Relationships to density and microstructure," Bone, vol. 30, pp. 229-237, Jan. 2002.
    • (2002) Bone , vol.30 , pp. 229-237
    • Chaffai, S.1    Peyrin, F.2    Nuzzo, S.3    Porcher, R.4    Berger, G.5    Laugier, P.6
  • 40
    • 33644664253 scopus 로고    scopus 로고
    • Ultrasonic characterization of human trabecular bone microstructure
    • Mar
    • M. A. Hakulinen, J. S. Day, J. Toyras, H. Weinans, and J. S. Jurvelin, "Ultrasonic characterization of human trabecular bone microstructure," Phys. Med. Biol., vol. 51, pp. 1633-1648, Mar. 2006.
    • (2006) Phys. Med. Biol , vol.51 , pp. 1633-1648
    • Hakulinen, M.A.1    Day, J.S.2    Toyras, J.3    Weinans, H.4    Jurvelin, J.S.5
  • 41
    • 0031170929 scopus 로고    scopus 로고
    • Inter-system comparison of site matched ultrasonic measurements of the calcaneous in-vitro
    • June
    • P. H. F. Nicholson, P. Droin, and P. Laugier, "Inter-system comparison of site matched ultrasonic measurements of the calcaneous in-vitro," Eur. J. Ultrasound, vol. 5, pp. 191-202, June 1997.
    • (1997) Eur. J. Ultrasound , vol.5 , pp. 191-202
    • Nicholson, P.H.F.1    Droin, P.2    Laugier, P.3
  • 42
    • 33750285999 scopus 로고    scopus 로고
    • Anomalous negative dispersion in bone can results from the interference of fast and slow waves
    • Nov
    • K. R. Marutyan, M. R. Holland, and J. G. Miller, "Anomalous negative dispersion in bone can results from the interference of fast and slow waves,"J. Acoust. Soc. Amer., vol. 120, pp. EL55-EL61, Nov. 2006.
    • (2006) J. Acoust. Soc. Amer , vol.120
    • Marutyan, K.R.1    Holland, M.R.2    Miller, J.G.3
  • 43
    • 29244484447 scopus 로고    scopus 로고
    • Kramers-Kronig analysis of attenuation and dispersion in trabecular bone
    • Dec
    • K. R. Waters and B. K. Hoffmeister, "Kramers-Kronig analysis of attenuation and dispersion in trabecular bone," J. Acoust. Soc. Amer., vol. 118, pp. 3912-3920, Dec. 2006.
    • (2006) J. Acoust. Soc. Amer , vol.118 , pp. 3912-3920
    • Waters, K.R.1    Hoffmeister, B.K.2
  • 44
    • 0002357545 scopus 로고
    • Temperature dependency of ultrasonic propagation properties through cancellous bone
    • J. M. Greenleaf, Ed. Boca Raton, FL: CRC Press
    • M. J. Haney and W. D. O'Brien, "Temperature dependency of ultrasonic propagation properties through cancellous bone," in Tissue Characterization with Ultrasound. J. M. Greenleaf, Ed. Boca Raton, FL: CRC Press, 1986, pp. 15-55.
    • (1986) Tissue Characterization with Ultrasound , pp. 15-55
    • Haney, M.J.1    O'Brien, W.D.2
  • 45
    • 0036226159 scopus 로고    scopus 로고
    • Bone marrow influences quantitative ultrasound measurements in human can-cellous bone
    • Mar
    • P. H. F. Nicholson and M. L. Bouxsein, "Bone marrow influences quantitative ultrasound measurements in human can-cellous bone," Ultrasound Med. Biol., vol. 28, pp. 369-375, Mar. 2002.
    • (2002) Ultrasound Med. Biol , vol.28 , pp. 369-375
    • Nicholson, P.H.F.1    Bouxsein, M.L.2
  • 46
    • 0034037757 scopus 로고    scopus 로고
    • Temperature dependence of ultrasonic attenuation in human calcaneous
    • Mar
    • K. A. Wear, "Temperature dependence of ultrasonic attenuation in human calcaneous," Ultrasound Med. Biol., vol. 26, pp. 469-472, Mar. 2000.
    • (2000) Ultrasound Med. Biol , vol.26 , pp. 469-472
    • Wear, K.A.1
  • 47
    • 0036852684 scopus 로고    scopus 로고
    • Effect of temperature of ultrasonic properties of the calcaneus in situ
    • Nov
    • P. H. F. Nicholson and M. L. Bouxsein, "Effect of temperature of ultrasonic properties of the calcaneus in situ," Osteoporos. Int., vol. 13, pp. 888-892, Nov. 2002.
    • (2002) Osteoporos. Int , vol.13 , pp. 888-892
    • Nicholson, P.H.F.1    Bouxsein, M.L.2
  • 48
    • 44949186805 scopus 로고    scopus 로고
    • Ultrasound guided placement of pedicle screws in spinal fusion surgery
    • M. Mujagic, H. J. Ginsberg, and R. S. C. Cobbold, "Ultrasound guided placement of pedicle screws in spinal fusion surgery," in Proc. IEEE Ultrason. Symp., 2007, pp. 212-215.
    • (2007) Proc. IEEE Ultrason. Symp , pp. 212-215
    • Mujagic, M.1    Ginsberg, H.J.2    Cobbold, R.S.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.