메뉴 건너뛰기




Volumn 12, Issue 1, 2008, Pages 10-14

Optimal positioning of right-sided internal jugular venous catheters: Comparison of intra-atrial electrocardiography versus Peres' formula

Author keywords

Central venous catheterization; Intra atrial electrocardiography; Peres' height formula

Indexed keywords

CENTRAL VENOUS PRESSURE; COMPARATIVE STUDY; ELECTROCARDIOGRAPHY; HEMODYNAMICS; HUMAN; INTERNAL JUGULAR VEIN; INTRAOPERATIVE PERIOD; INTRAVENOUS CATHETER; MAJOR SURGERY; POSTOPERATIVE PERIOD; REVIEW; TECHNIQUE; THORAX RADIOGRAPHY;

EID: 44849119803     PISSN: 09725229     EISSN: 1998359X     Source Type: Journal    
DOI: 10.4103/0972-5229.40943     Document Type: Review
Times cited : (26)

References (20)
  • 1
    • 0018406888 scopus 로고
    • Cardiac tamponade from central venous catheters
    • Defalque RJ, Campbell C. Cardiac tamponade from central venous catheters. Anesthesiology 1979;50:249-52.
    • (1979) Anesthesiology , vol.50 , pp. 249-252
    • Defalque, R.J.1    Campbell, C.2
  • 2
    • 0033854378 scopus 로고    scopus 로고
    • The carina as a radiological landmark in central venous catheter placement
    • Schuster M, Nave H, Piepenbrock S. The carina as a radiological landmark in central venous catheter placement. Br J Anaesth 2000;85:192-4.
    • (2000) Br J Anaesth , vol.85 , pp. 192-194
    • Schuster, M.1    Nave, H.2    Piepenbrock, S.3
  • 3
    • 33244463057 scopus 로고    scopus 로고
    • The carina as a radiological landmark for central venous catheter tip position
    • Stonelake PA, Bodenham AR. The carina as a radiological landmark for central venous catheter tip position. Br J Anaesth 2006;96:335-40.
    • (2006) Br J Anaesth , vol.96 , pp. 335-340
    • Stonelake, P.A.1    Bodenham, A.R.2
  • 4
    • 0029026293 scopus 로고
    • Evaluation of formulas for optimal positioning of central venous catheters
    • Czepizak CA, O'Callaghan JM, Venus B. Evaluation of formulas for optimal positioning of central venous catheters. Chest 1995;107:1662-4.
    • (1995) Chest , vol.107 , pp. 1662-1664
    • Czepizak, C.A.1    O'Callaghan, J.M.2    Venus, B.3
  • 5
    • 0031951427 scopus 로고    scopus 로고
    • Depth of central venous catheter insertion in adults: An audit and assessment of a technique to improve tip position
    • Chalkiadis GA, Goucke CR. Depth of central venous catheter insertion in adults: an audit and assessment of a technique to improve tip position. Anesth Intensive Care 1998;26:61-6.
    • (1998) Anesth Intensive Care , vol.26 , pp. 61-66
    • Chalkiadis, G.A.1    Goucke, C.R.2
  • 6
    • 0023870474 scopus 로고
    • Right atrial electrocardiography in placement of central venous catheters
    • Wilson RG, Gaer JA. Right atrial electrocardiography in placement of central venous catheters. Lancet 1988;27:462-3.
    • (1988) Lancet , vol.27 , pp. 462-463
    • Wilson, R.G.1    Gaer, J.A.2
  • 7
    • 34447542543 scopus 로고    scopus 로고
    • Transesophageal echocardiographic evaluation of ECG-guided central venous catheter placement
    • Jeon Y, Ryu HG, Yoon SZ, Kim JH, Bahk JH. Transesophageal echocardiographic evaluation of ECG-guided central venous catheter placement. Can J Anesth 2006;53:978-83.
    • (2006) Can J Anesth , vol.53 , pp. 978-983
    • Jeon, Y.1    Ryu, H.G.2    Yoon, S.Z.3    Kim, J.H.4    Bahk, J.H.5
  • 8
    • 0033051551 scopus 로고    scopus 로고
    • A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients
    • Andropoulos DB, Stayer SA, Bent ST, Campos CJ, Alvarez M, Fraser CD. A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients. Anesth Analg 1999;89:65-70.
    • (1999) Anesth Analg , vol.89 , pp. 65-70
    • Andropoulos, D.B.1    Stayer, S.A.2    Bent, S.T.3    Campos, C.J.4    Alvarez, M.5    Fraser, C.D.6
  • 9
    • 0024996909 scopus 로고
    • Positioning central venous catheters: A prospective survey
    • Peres PW. Positioning central venous catheters: A prospective survey. Anesth Intensive Care 1990;18:536-9.
    • (1990) Anesth Intensive Care , vol.18 , pp. 536-539
    • Peres, P.W.1
  • 10
    • 0002867506 scopus 로고
    • Recording of intracavity potentials through a single lumen, saline filled cardiac catheter
    • Hellerstein HK, Pritchard WH, Lewis RL. Recording of intracavity potentials through a single lumen, saline filled cardiac catheter. Proc Soc Exp Med 1949;71:58-60.
    • (1949) Proc Soc Exp Med , vol.71 , pp. 58-60
    • Hellerstein, H.K.1    Pritchard, W.H.2    Lewis, R.L.3
  • 11
    • 0033859579 scopus 로고    scopus 로고
    • Safe placement of central venous catheters: Where should the tip of the catheter lie?
    • Fletcher SJ, Bodenham AR. Safe placement of central venous catheters: Where should the tip of the catheter lie? Br J Anaesth 2000;85:188-91.
    • (2000) Br J Anaesth , vol.85 , pp. 188-191
    • Fletcher, S.J.1    Bodenham, A.R.2
  • 12
    • 0028213997 scopus 로고
    • Depth of central venous catheterization: An audit of practice in a cardiac surgical unit
    • Rutherford JS, Merry AF, Occleshaw CJ. Depth of central venous catheterization: An audit of practice in a cardiac surgical unit. Anaesth Intensive Care 1994;22:267-71.
    • (1994) Anaesth Intensive Care , vol.22 , pp. 267-271
    • Rutherford, J.S.1    Merry, A.F.2    Occleshaw, C.J.3
  • 14
    • 0348227677 scopus 로고    scopus 로고
    • Applied anatomy of the superior vena cava-the carina as a radiological landmark to guide central venous catheter placement
    • Albrecht K, Nave H, Breitmeier D, Panning B, Tröger HD. Applied anatomy of the superior vena cava-the carina as a radiological landmark to guide central venous catheter placement. Br J Anaesth 2004;92:75-7.
    • (2004) Br J Anaesth , vol.92 , pp. 75-77
    • Albrecht, K.1    Nave, H.2    Breitmeier, D.3    Panning, B.4    Tröger, H.D.5
  • 15
    • 26444522294 scopus 로고    scopus 로고
    • Usefullness of the carina as a radiological landmark for central vanous catheter placement in paediatric patients
    • Yoon SZ, Shin JH, Hahn S. Usefullness of the carina as a radiological landmark for central vanous catheter placement in paediatric patients. Br J Anaesth 2005;95:514-7.
    • (2005) Br J Anaesth , vol.95 , pp. 514-517
    • Yoon, S.Z.1    Shin, J.H.2    Hahn, S.3
  • 16
    • 0037961053 scopus 로고    scopus 로고
    • A better landmark for positioning a central vanous catheter
    • Caruso LJ, Gravenstein N, Layon AJ. A better landmark for positioning a central vanous catheter. J Clin Monit Comput 2002;17:331-4.
    • (2002) J Clin Monit Comput , vol.17 , pp. 331-334
    • Caruso, L.J.1    Gravenstein, N.2    Layon, A.J.3
  • 17
    • 0342684473 scopus 로고    scopus 로고
    • Use of electrocardiogram to position right atrial catheters during surgery
    • Watters VA, Grant JP. Use of electrocardiogram to position right atrial catheters during surgery. Ann Surg 1997;225:165-71.
    • (1997) Ann Surg , vol.225 , pp. 165-171
    • Watters, V.A.1    Grant, J.P.2
  • 18
    • 0026706486 scopus 로고
    • Avoiding complications and decreasing costs of central venous catheter placement electrocardiographic guidance
    • Francis KR, Picard DL, Fajardo MA, Pizzi WF. Avoiding complications and decreasing costs of central venous catheter placement electrocardiographic guidance. Surg Gynecol Obstet 1992;175:208-11.
    • (1992) Surg Gynecol Obstet , vol.175 , pp. 208-211
    • Francis, K.R.1    Picard, D.L.2    Fajardo, M.A.3    Pizzi, W.F.4
  • 19
    • 33847620165 scopus 로고    scopus 로고
    • The Accuracy of electrocardiogram controlled central line placement
    • Gebhard RE, Szmuk P, Pivalizza EG. The Accuracy of electrocardiogram controlled central line placement Anesth Analg 2007;104:65-70.
    • (2007) Anesth Analg , vol.104 , pp. 65-70
    • Gebhard, R.E.1    Szmuk, P.2    Pivalizza, E.G.3
  • 20
    • 0142031475 scopus 로고    scopus 로고
    • Intra-atrial ECG is not a reliable method for positioning left internal jugular vein catheters
    • Schummer W, Herrmann S, Schummer C. Intra-atrial ECG is not a reliable method for positioning left internal jugular vein catheters. Br J Anaesth 2003;91:481-6.
    • (2003) Br J Anaesth , vol.91 , pp. 481-486
    • Schummer, W.1    Herrmann, S.2    Schummer, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.