메뉴 건너뛰기




Volumn 104, Issue 1, 2007, Pages 65-70

The accuracy of electrocardiogram-controlled central line placement

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CENTRAL VENOUS CATHETER; CENTRAL VENOUS CATHETERIZATION; CONTROLLED STUDY; COST CONTROL; ELECTROCARDIOGRAM; FEMALE; HEALTH CARE COST; HEART RIGHT ATRIUM; HEART RIGHT VENTRICLE; HUMAN; MAJOR CLINICAL STUDY; MALE; PATIENT SAFETY; PRIORITY JOURNAL; SUPERIOR CAVA VEIN; SURGICAL PATIENT; BODY WEIGHT; CLINICAL TRIAL; COMPUTER PROGRAM; CONTROLLED CLINICAL TRIAL; ELECTIVE SURGERY; ELECTROCARDIOGRAPHY; METHODOLOGY; MIDDLE AGED; MONITORING; PATIENT SELECTION; PREOPERATIVE CARE; RANDOMIZED CONTROLLED TRIAL; SAFETY; STANDARD;

EID: 33847620165     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ane.0000250224.02440.fe     Document Type: Article
Times cited : (101)

References (19)
  • 1
    • 0026315292 scopus 로고
    • Pericardial tamponade secondary to perforation by central venous catheters in orthopaedic patients
    • Kalen V, Medige TA, Rinsky LA. Pericardial tamponade secondary to perforation by central venous catheters in orthopaedic patients. J Bone Joint Surg Am 1991;73:1503-6.
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 1503-1506
    • Kalen, V.1    Medige, T.A.2    Rinsky, L.A.3
  • 2
    • 0034871594 scopus 로고    scopus 로고
    • Central venous catheterization and fatal cardiac tamponade
    • Booth SA, Norton B, Mulvey DA. Central venous catheterization and fatal cardiac tamponade. Br J Anaesth 2001;87:298-302.
    • (2001) Br J Anaesth , vol.87 , pp. 298-302
    • Booth, S.A.1    Norton, B.2    Mulvey, D.A.3
  • 3
    • 0029334190 scopus 로고
    • Central venous catheters: An overview of food and drug administration activities
    • Scott WL. Central venous catheters: an overview of food and drug administration activities. Surg Oncol Clin N Am 1995;4:377-92.
    • (1995) Surg Oncol Clin N Am , vol.4 , pp. 377-392
    • Scott, W.L.1
  • 4
    • 0036715711 scopus 로고    scopus 로고
    • Complications of invasive monitoring
    • Bowdle TA. Complications of invasive monitoring. Anesthesiol Clin North America 2002;20:571-88.
    • (2002) Anesthesiol Clin North America , vol.20 , pp. 571-588
    • Bowdle, T.A.1
  • 5
    • 0028594070 scopus 로고
    • Central venous catheter placement using the ECG-guided Cavafix-Certodyn SD catheter
    • Corsten SA, van Dijk B, Bakker NC, et al. Central venous catheter placement using the ECG-guided Cavafix-Certodyn SD catheter. J Clin Anesth 1994;6:469-72.
    • (1994) J Clin Anesth , vol.6 , pp. 469-472
    • Corsten, S.A.1    van Dijk, B.2    Bakker, N.C.3
  • 6
    • 0026706486 scopus 로고
    • Avoiding complications and decreasing costs of central venous catheter placement utilizing electrocardiographic guidance
    • Francis KR, Picard DL, Fajardo MA, Pizzi WF. Avoiding complications and decreasing costs of central venous catheter placement utilizing electrocardiographic guidance. Surg Gynecol Obstet 1992;175:208-11.
    • (1992) Surg Gynecol Obstet , vol.175 , pp. 208-211
    • Francis, K.R.1    Picard, D.L.2    Fajardo, M.A.3    Pizzi, W.F.4
  • 7
    • 0025720450 scopus 로고
    • CVP catheter electrocardiography: An alternative to radiographic control after cannulation of central veins?
    • Koscielniak-Nielsen ZJ, Otkjaer S, Hansen OB, Hemmingsen C. CVP catheter electrocardiography: an alternative to radiographic control after cannulation of central veins? Acta Anaesthesiol Scand 1991;35:762-6.
    • (1991) Acta Anaesthesiol Scand , vol.35 , pp. 762-766
    • Koscielniak-Nielsen, Z.J.1    Otkjaer, S.2    Hansen, O.B.3    Hemmingsen, C.4
  • 8
    • 0037456765 scopus 로고    scopus 로고
    • Preventing complications of central venous catheterization
    • McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med 2003;348:1123-33.
    • (2003) N Engl J Med , vol.348 , pp. 1123-1133
    • McGee, D.C.1    Gould, M.K.2
  • 9
    • 0032859208 scopus 로고    scopus 로고
    • Routine chest radiographs after central line insertion: Mandatory postprocedural evaluation or unnecessary waste of resources
    • Lucey B, Varghese JC, Haslam P, Lee MJ. Routine chest radiographs after central line insertion: mandatory postprocedural evaluation or unnecessary waste of resources. Cardiovasc Intervent Radiol 1999;22:381-4.
    • (1999) Cardiovasc Intervent Radiol , vol.22 , pp. 381-384
    • Lucey, B.1    Varghese, J.C.2    Haslam, P.3    Lee, M.J.4
  • 10
    • 0002867506 scopus 로고
    • Recording of intracavity potentials through a single-lumen saline filled cardiac catheter
    • von Hellerstein HK, Pritchard WH, Lewis RL. Recording of intracavity potentials through a single-lumen saline filled cardiac catheter. Proc Soc Exp Biol Med 1949;71:58-60.
    • (1949) Proc Soc Exp Biol Med , vol.71 , pp. 58-60
    • von Hellerstein, H.K.1    Pritchard, W.H.2    Lewis, R.L.3
  • 11
    • 0027293750 scopus 로고
    • Accurate placement of central venous catheters: A prospective, randomized, multicenter trial
    • McGee WT, Ackerman BL, Rouben LR, et al. Accurate placement of central venous catheters: a prospective, randomized, multicenter trial. Crit Care Med 1993;21:1118-23.
    • (1993) Crit Care Med , vol.21 , pp. 1118-1123
    • McGee, W.T.1    Ackerman, B.L.2    Rouben, L.R.3
  • 12
    • 0030057557 scopus 로고    scopus 로고
    • Accurate placement of central venous catheters using a 16-cm catheter
    • McGee WT, Moriarty KP. Accurate placement of central venous catheters using a 16-cm catheter. J Intensive Care Med 1996;11:19-22.
    • (1996) J Intensive Care Med , vol.11 , pp. 19-22
    • McGee, W.T.1    Moriarty, K.P.2
  • 13
    • 0142031475 scopus 로고    scopus 로고
    • Intra-atrial ECG is not a reliable method for positioning left internal jugular vein catheters
    • Schummer W, Herrmann S, Schummer C, et al. Intra-atrial ECG is not a reliable method for positioning left internal jugular vein catheters. Br J Anaesth 2003;91:481-6.
    • (2003) Br J Anaesth , vol.91 , pp. 481-486
    • Schummer, W.1    Herrmann, S.2    Schummer, C.3
  • 14
    • 0026093362 scopus 로고
    • In vitro evaluation of relative perforating potential of central venous catheters: Comparison of materials, selected models, number of lumens, and angles of incidence to simulated membrane
    • Gravenstein N, Blackshear RH. In vitro evaluation of relative perforating potential of central venous catheters: comparison of materials, selected models, number of lumens, and angles of incidence to simulated membrane. J Clin Monit 1991;7:1-6.
    • (1991) J Clin Monit , vol.7 , pp. 1-6
    • Gravenstein, N.1    Blackshear, R.H.2
  • 16
    • 0035724545 scopus 로고    scopus 로고
    • Radiologic placement of central venous catheters: Rates of success and immediate complications in 3412 cases
    • Tseng M, Sadler D, Wong J, et al. Radiologic placement of central venous catheters: rates of success and immediate complications in 3412 cases. Can Assoc Radiol J 2001;52:379-84.
    • (2001) Can Assoc Radiol J , vol.52 , pp. 379-384
    • Tseng, M.1    Sadler, D.2    Wong, J.3
  • 17
    • 4344659676 scopus 로고    scopus 로고
    • Central venous catheters - the inability of intra-atrial ECG to prove adequate positioning
    • Schummer W, Schummer C, Schelenz C, et al. Central venous catheters - the inability of intra-atrial ECG to prove adequate positioning. Br J Anaesth 2004;93:193-8.
    • (2004) Br J Anaesth , vol.93 , pp. 193-198
    • Schummer, W.1    Schummer, C.2    Schelenz, C.3
  • 18
    • 85046172315 scopus 로고    scopus 로고
    • The incidence of artery puncture with central venous cannulation using a modified technique for detection and prevention of arterial cannulation
    • Oliver WC Jr, Nutall GA, Beynen FM, et al. The incidence of artery puncture with central venous cannulation using a modified technique for detection and prevention of arterial cannulation. J Cardiothorac Vasc Anesth 1997;12:495-6.
    • (1997) J Cardiothorac Vasc Anesth , vol.12 , pp. 495-496
    • Oliver Jr, W.C.1    Nutall, G.A.2    Beynen, F.M.3
  • 19
    • 0036794171 scopus 로고    scopus 로고
    • Current practice of internal jugular venous cannulation in a university department: Influence of operator experience on success of cannulation and arterial injury
    • Augoustides JG, Diaz D, Weiner J, et al. Current practice of internal jugular venous cannulation in a university department: influence of operator experience on success of cannulation and arterial injury. J Cardiothorac Vasc Anesth 2002;16:567-71.
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 567-571
    • Augoustides, J.G.1    Diaz, D.2    Weiner, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.