메뉴 건너뛰기




Volumn 29, Issue 6, 2008, Pages 581-586

Rigidity comparison of locking plate and intramedullary fixation for tibiotalocalcaneal arthrodesis

Author keywords

Arthrodesis; Fusion; Locking plate; Tibiotalocalcaneal

Indexed keywords

ADULT; AGED; ARTICLE; CADAVER; HUMAN; INTRAMEDULLARY NAILING; PLATE FIXATION; PRIORITY JOURNAL; RIGIDITY; STATISTICAL ANALYSIS; STUDENT T TEST; SUBTALAR ARTHRODESIS; SUBTALAR JOINT;

EID: 44849113287     PISSN: 10711007     EISSN: None     Source Type: Journal    
DOI: 10.3113/FAI.2008.0581     Document Type: Article
Times cited : (61)

References (20)
  • 1
    • 0030861423 scopus 로고    scopus 로고
    • A biomechanical comparison of intramedullary nail and crossed lag screw fixation for tibiotalocalcaneal arthrodesis
    • Berend, ME; Glisson, RR; Nunley, JA: A biomechanical comparison of intramedullary nail and crossed lag screw fixation for tibiotalocalcaneal arthrodesis. Foot Ankle Int. 18:639-643, 1997.
    • (1997) Foot Ankle Int , vol.18 , pp. 639-643
    • Berend, M.E.1    Glisson, R.R.2    Nunley, J.A.3
  • 2
    • 10944263139 scopus 로고    scopus 로고
    • Internal fixation of proximal humeral fractures with a locking compression plate: A retrospective evaluation of 72 patients followed for a minimum of 1 year
    • Bjorkenheim, JM; Pajarinen, J; Savolainen, V: Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop. Scand. 75:741-745, 2004.
    • (2004) Acta Orthop. Scand , vol.75 , pp. 741-745
    • Bjorkenheim, J.M.1    Pajarinen, J.2    Savolainen, V.3
  • 3
    • 0032720511 scopus 로고    scopus 로고
    • Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail
    • Brumback, RJ; Toal, TR, Jr.; Murphy-Zane, MS; Novak, VP; Belkoff, SM: Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail. J. Bone Joint Surg. Am. 81:1538-1544, 1999.
    • (1999) J. Bone Joint Surg. Am , vol.81 , pp. 1538-1544
    • Brumback, R.J.1    Toal Jr., T.R.2    Murphy-Zane, M.S.3    Novak, V.P.4    Belkoff, S.M.5
  • 4
    • 33646905915 scopus 로고    scopus 로고
    • The use of locking plates in fracture care
    • Cantu, RV; Koval, KJ: The use of locking plates in fracture care. J. Am. Acad. Orthop. Surg. 14:183-190, 2006.
    • (2006) J. Am. Acad. Orthop. Surg , vol.14 , pp. 183-190
    • Cantu, R.V.1    Koval, K.J.2
  • 5
    • 0344198029 scopus 로고    scopus 로고
    • Intramedullary rod fixation compared with blade-plate-and-screw fixation for tibiotalocalcaneal arthrodesis: A biomechanical investigation
    • Chiodo, CP; Acevedo, J; Sammarco, VJ; et al.: Intramedullary rod fixation compared with blade-plate-and-screw fixation for tibiotalocalcaneal arthrodesis: a biomechanical investigation. J. Bone Joint Surg. Am. 85:2425-2428, 2003.
    • (2003) J. Bone Joint Surg. Am , vol.85 , pp. 2425-2428
    • Chiodo, C.P.1    Acevedo, J.2    Sammarco, V.J.3
  • 6
    • 0033773583 scopus 로고    scopus 로고
    • Tibiotalocalcaneal arthrodesis
    • Chou, LB; Mann, RA; Yaszay, B; et al.: Tibiotalocalcaneal arthrodesis. Foot Ankle Int. 21:804-808, 2000.
    • (2000) Foot Ankle Int , vol.21 , pp. 804-808
    • Chou, L.B.1    Mann, R.A.2    Yaszay, B.3
  • 9
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques
    • Fulkerson, E; Egol, KA; Kubiak, EN; et al.: Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J. Trauma 60:830-835, 2006. http://dx.doi.org/10.1097/01.ta.0000195462.53525.0c
    • (2006) J. Trauma , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.3
  • 10
    • 7444234973 scopus 로고    scopus 로고
    • Innovations in locking plate technology
    • Haidukewych, GJ: Innovations in locking plate technology. J. Am. Acad. Orthop. Surg. 12:205-212, 2004.
    • (2004) J. Am. Acad. Orthop. Surg , vol.12 , pp. 205-212
    • Haidukewych, G.J.1
  • 11
    • 2642514242 scopus 로고    scopus 로고
    • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    • Korner, J; Diederichs, G; Arzdorf, M; et al.: A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J. Orthop. Trauma 18:286-293, 2004. http://dx.doi.org/10.1097/00005131-200405000-00004
    • (2004) J. Orthop. Trauma , vol.18 , pp. 286-293
    • Korner, J.1    Diederichs, G.2    Arzdorf, M.3
  • 12
    • 33845404678 scopus 로고    scopus 로고
    • Intramedullary nail fixation with posterior-to-anterior compared to transverse distal screw placement for tibiotalocalcaneal arthrodesis: A biomechanical investigation
    • Means, KR, Jr; Parks, BG; Nguyen, A; Schon, LC: Intramedullary nail fixation with posterior-to-anterior compared to transverse distal screw placement for tibiotalocalcaneal arthrodesis: a biomechanical investigation. Foot Ankle Int 27:1137-1142, 2006.
    • (2006) Foot Ankle Int , vol.27 , pp. 1137-1142
    • Means Jr, K.R.1    Parks, B.G.2    Nguyen, A.3    Schon, L.C.4
  • 13
    • 0034902624 scopus 로고    scopus 로고
    • Biomechanical comparison of ankle arthrodesis techniques: Crossed screws vs. blade plate
    • Nasson, S; Shuff, C; Palmer, D; et al.: Biomechanical comparison of ankle arthrodesis techniques: crossed screws vs. blade plate. Foot Ankle Int. 22:575-580, 2001.
    • (2001) Foot Ankle Int , vol.22 , pp. 575-580
    • Nasson, S.1    Shuff, C.2    Palmer, D.3
  • 14
    • 34347389445 scopus 로고    scopus 로고
    • Biomechanical analysis of screw-augmented intramedullary fixation for tibiotalocalcaneal arthrodesis
    • O'Neill, PJ; Parks, BG; Walsh, R; Simmons, LM; Schon, LC: Biomechanical analysis of screw-augmented intramedullary fixation for tibiotalocalcaneal arthrodesis. Foot Ankle Int. 28:804-809, 2007. http://dx.doi.org/10.3113/FAI.2006.0804
    • (2007) Foot Ankle Int , vol.28 , pp. 804-809
    • O'Neill, P.J.1    Parks, B.G.2    Walsh, R.3    Simmons, L.M.4    Schon, L.C.5
  • 15
    • 0026787761 scopus 로고
    • Pantalar and tibiotalocalcaneal arthrodesis for post-traumatic osteoarthrosis of the ankle and hindfoot
    • Papa, JA; Myerson, MS: Pantalar and tibiotalocalcaneal arthrodesis for post-traumatic osteoarthrosis of the ankle and hindfoot. J. Bone Joint Surg. Am. 74:1042-1049, 1992.
    • (1992) J. Bone Joint Surg. Am , vol.74 , pp. 1042-1049
    • Papa, J.A.1    Myerson, M.S.2
  • 16
    • 0030667072 scopus 로고    scopus 로고
    • Charcot ankle fusion with a retrograde locked intramedullary nail
    • Pinzur, MS; Kelikian, A: Charcot ankle fusion with a retrograde locked intramedullary nail. Foot Ankle Int. 18:699-704, 1997.
    • (1997) Foot Ankle Int , vol.18 , pp. 699-704
    • Pinzur, M.S.1    Kelikian, A.2
  • 17
    • 33645314677 scopus 로고    scopus 로고
    • A biomechanical comparison of locking and nonlocking plates for the fixation of calcaneal fractures
    • Redfern, DJ; Oliveira, ML; Campbell, JT; Belkoff, SM: A biomechanical comparison of locking and nonlocking plates for the fixation of calcaneal fractures. Foot Ankle Int. 27:196-201, 2006.
    • (2006) Foot Ankle Int , vol.27 , pp. 196-201
    • Redfern, D.J.1    Oliveira, M.L.2    Campbell, J.T.3    Belkoff, S.M.4
  • 18
    • 16844365606 scopus 로고    scopus 로고
    • A comparison of plates with and without locking screws in a calcaneal fracture model
    • Richter, M; Gosling, T; Zech, S; et al.: A comparison of plates with and without locking screws in a calcaneal fracture model. Foot Ankle Int. 26:309-319, 2005.
    • (2005) Foot Ankle Int , vol.26 , pp. 309-319
    • Richter, M.1    Gosling, T.2    Zech, S.3
  • 19
    • 4043112149 scopus 로고    scopus 로고
    • Locking compression plates for osteoporotic nonunions of the diaphyseal humerus
    • Ring, D; Kloen, P; Kadzielski, J; Helfet, D; Jupiter, JB: Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin. Orthop. Relat. Res. 425:50-54, 2004. http://dx.doi.org/10.1097/01.blo. 0000131484.27501.4b
    • (2004) Clin. Orthop. Relat. Res , vol.425 , pp. 50-54
    • Ring, D.1    Kloen, P.2    Kadzielski, J.3    Helfet, D.4    Jupiter, J.B.5
  • 20
    • 0023811860 scopus 로고
    • Tibiotalocalcaneal arthrodesis for arthritis and deformity of the hind part of the foot
    • Russotti, GM; Johnson, KA; Cass, JR: Tibiotalocalcaneal arthrodesis for arthritis and deformity of the hind part of the foot. J. Bone Joint Surg. Am. 70:1304-1307, 1988.
    • (1988) J. Bone Joint Surg. Am , vol.70 , pp. 1304-1307
    • Russotti, G.M.1    Johnson, K.A.2    Cass, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.