1
-
-
0033322516
-
Burning characteristics of selected substances: production of heat, smoke and chemical species
-
Hietaniemi J., Kallonen R., and Mikkola E. Burning characteristics of selected substances: production of heat, smoke and chemical species. Fire Mater. 23 4 (1999) 171-185
-
(1999)
Fire Mater.
, vol.23
, Issue.4
, pp. 171-185
-
-
Hietaniemi, J.1
Kallonen, R.2
Mikkola, E.3
-
2
-
-
34247125365
-
Experimental study on the smoke components in the underground shopping center fire
-
(in Chinese)
-
Liu J.J., Lan B., Zhang W.L., et al. Experimental study on the smoke components in the underground shopping center fire. Fire Sci. Technol. 1 1 (2001) 10-12 (in Chinese)
-
(2001)
Fire Sci. Technol.
, vol.1
, Issue.1
, pp. 10-12
-
-
Liu, J.J.1
Lan, B.2
Zhang, W.L.3
-
3
-
-
16644387452
-
The study on the air flow and heat transfer of vertical display case
-
Meng X.Z., Yu B.F., and Wang F.H. The study on the air flow and heat transfer of vertical display case. Fluid Mach. 29 2 (2001) 50-52
-
(2001)
Fluid Mach.
, vol.29
, Issue.2
, pp. 50-52
-
-
Meng, X.Z.1
Yu, B.F.2
Wang, F.H.3
-
4
-
-
44649095565
-
-
K.B. McGrattan, A. Hamins, D. Stroup, Sprinkler, Smoke & Heat Vent, Draft Curtain Interaction-Large Scale Experiments and Model Development, National Institute of Standards and Technology, Gaithersburg, MD, NISTIR 6196-1, September 1998.
-
K.B. McGrattan, A. Hamins, D. Stroup, Sprinkler, Smoke & Heat Vent, Draft Curtain Interaction-Large Scale Experiments and Model Development, National Institute of Standards and Technology, Gaithersburg, MD, NISTIR 6196-1, September 1998.
-
-
-
-
5
-
-
0344891375
-
Design of air curtains used for area confinement in tunnels
-
Guyonnaud L., and Solliec C. Design of air curtains used for area confinement in tunnels. Exp. Fluids 28 (2000) 377-384
-
(2000)
Exp. Fluids
, vol.28
, pp. 377-384
-
-
Guyonnaud, L.1
Solliec, C.2
-
6
-
-
33745037992
-
Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration
-
Foster A.M., Swain M.J., Barrett R., D'Agaro P., and James S.J. Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration. Int. J. Refrig. 29 (2006) 692-699
-
(2006)
Int. J. Refrig.
, vol.29
, pp. 692-699
-
-
Foster, A.M.1
Swain, M.J.2
Barrett, R.3
D'Agaro, P.4
James, S.J.5
-
7
-
-
0017814557
-
The linear air curtain as a particulate barrier
-
Roberson P., and Shaw B.H. The linear air curtain as a particulate barrier. J. Environ. Sci. 21 (1978) 32-33
-
(1978)
J. Environ. Sci.
, vol.21
, pp. 32-33
-
-
Roberson, P.1
Shaw, B.H.2
-
8
-
-
0007529329
-
Analytical design of an air curtain
-
Partyka J. Analytical design of an air curtain. Int. J. Model. Simul. 15 (1995) 14-22
-
(1995)
Int. J. Model. Simul.
, vol.15
, pp. 14-22
-
-
Partyka, J.1
-
9
-
-
44649192259
-
-
M.A. Szatmary, Isolation chamber air curtain apparatus, Patent WO 98 50134, 1997.
-
M.A. Szatmary, Isolation chamber air curtain apparatus, Patent WO 98 50134, 1997.
-
-
-
-
10
-
-
1842698393
-
An isothermal air curtain for isolation of smoking areas in restaurants
-
Awbi H.B. (Ed), Elsevier
-
Rydock J.P., Hestad T., Haugen H., and Skaret J.E. An isothermal air curtain for isolation of smoking areas in restaurants. In: Awbi H.B. (Ed). Air distribution in Rooms (Roomvent 2000) (2000), Elsevier 664-668
-
(2000)
Air distribution in Rooms (Roomvent 2000)
, pp. 664-668
-
-
Rydock, J.P.1
Hestad, T.2
Haugen, H.3
Skaret, J.E.4
-
11
-
-
0035183206
-
Odour and VOC confining in large enclosures using air curtains
-
Pavageau M., Nieto E., and Rey C. Odour and VOC confining in large enclosures using air curtains. Water Sci. Technol. 44 9 (2001) 165-171
-
(2001)
Water Sci. Technol.
, vol.44
, Issue.9
, pp. 165-171
-
-
Pavageau, M.1
Nieto, E.2
Rey, C.3
-
12
-
-
34247172856
-
Cellular confinement of tunnel sections between two air curtains
-
Gupta S., Pavageaua M., and Elicer-Cortes J.-C. Cellular confinement of tunnel sections between two air curtains. Build. Environ. 42 (2007) 3352-3365
-
(2007)
Build. Environ.
, vol.42
, pp. 3352-3365
-
-
Gupta, S.1
Pavageaua, M.2
Elicer-Cortes, J.-C.3
-
15
-
-
10444236854
-
-
National Institute of Standards and Technology, NISTGCR01-810, Gaithersburg, MD
-
Friday P.A., and Mowrer F.W. Comparison of FDS Model Predictions with FM/SNL Fire Test Data (2001), National Institute of Standards and Technology, NISTGCR01-810, Gaithersburg, MD
-
(2001)
Comparison of FDS Model Predictions with FM/SNL Fire Test Data
-
-
Friday, P.A.1
Mowrer, F.W.2
-
16
-
-
0037773268
-
-
National Institute of Standards and Technology, NIST Special Publication 1019, Gaithersburg, MD
-
McGrattan K.B., and Forney G.P. Fire Dynamics Simulator (Version 4.07)-User's Guide (2006), National Institute of Standards and Technology, NIST Special Publication 1019, Gaithersburg, MD
-
(2006)
Fire Dynamics Simulator (Version 4.07)-User's Guide
-
-
McGrattan, K.B.1
Forney, G.P.2
-
17
-
-
44649128446
-
-
http://www.nist.gov/fds.
-
http://www.nist.gov/fds.
-
-
-
-
18
-
-
7044224745
-
Consequence modeling using the fire dynamics simulator
-
Ryder N.L., Sutula J.A., Schemel C.F., Hamer A.J., and Brunt V.V. Consequence modeling using the fire dynamics simulator. J. Hazard. Mater. 115 (2004) 149-154
-
(2004)
J. Hazard. Mater.
, vol.115
, pp. 149-154
-
-
Ryder, N.L.1
Sutula, J.A.2
Schemel, C.F.3
Hamer, A.J.4
Brunt, V.V.5
-
19
-
-
33644638257
-
Near and far field contamination modeling in a large scale enclosure: fire dynamics simulator comparisons with measured observations
-
Ryder N.L., Schemel C.F., and Jankiewicz S.P. Near and far field contamination modeling in a large scale enclosure: fire dynamics simulator comparisons with measured observations. J. Hazard. Mater. 130 (2006) 182-186
-
(2006)
J. Hazard. Mater.
, vol.130
, pp. 182-186
-
-
Ryder, N.L.1
Schemel, C.F.2
Jankiewicz, S.P.3
-
20
-
-
11944253113
-
Full-scale burning tests on studying smoke temperature and velocity along a corridor
-
Hu L.H., Huo R., Li Y.Z., Wang H.B., and Chow W.K. Full-scale burning tests on studying smoke temperature and velocity along a corridor. Tunn. Undergr. Space Technol. 20 3 (2005) 223-229
-
(2005)
Tunn. Undergr. Space Technol.
, vol.20
, Issue.3
, pp. 223-229
-
-
Hu, L.H.1
Huo, R.2
Li, Y.Z.3
Wang, H.B.4
Chow, W.K.5
-
21
-
-
33745984215
-
Full-scale experimental studies on mechanical smoke exhaust efficiency in an underground corridor
-
Hu L.H., Li Y.Z., Huo R., Yi L., and Chow W.K. Full-scale experimental studies on mechanical smoke exhaust efficiency in an underground corridor. Build. Environ. 41 12 (2006) 1622-1630
-
(2006)
Build. Environ.
, vol.41
, Issue.12
, pp. 1622-1630
-
-
Hu, L.H.1
Li, Y.Z.2
Huo, R.3
Yi, L.4
Chow, W.K.5
-
22
-
-
33846662757
-
Modeling fire-induced smoke spread and carbon monoxide transportation in a long channel: fire dynamics simulator comparisons with measured data
-
Hu L.H., Fong N.K., Yang L.Z., Chow W.K., Li Y.Z., and Huo R. Modeling fire-induced smoke spread and carbon monoxide transportation in a long channel: fire dynamics simulator comparisons with measured data. J. Hazard. Mater. 140 (2007) 293-298
-
(2007)
J. Hazard. Mater.
, vol.140
, pp. 293-298
-
-
Hu, L.H.1
Fong, N.K.2
Yang, L.Z.3
Chow, W.K.4
Li, Y.Z.5
Huo, R.6
|