메뉴 건너뛰기




Volumn 29, Issue 5, 2006, Pages 692-699

Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration

Author keywords

Air; Air curtain; Cold room; Efficiency; Jet; Optimization; Speed

Indexed keywords

AIR; COMPUTATIONAL FLUID DYNAMICS; EFFICIENCY; INFILTRATION; JET AIRCRAFT; OPTIMIZATION; SPEED;

EID: 33745037992     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2005.12.011     Document Type: Article
Times cited : (100)

References (22)
  • 1
    • 0036713076 scopus 로고    scopus 로고
    • An empirical model for predicting air infiltration into refrigerated stores through doors
    • Chen P., Cleland D.J., Lovatt S.J., and Bassett M.R. An empirical model for predicting air infiltration into refrigerated stores through doors. Int. J. Refrigeration 25 (2002) 799-812
    • (2002) Int. J. Refrigeration , vol.25 , pp. 799-812
    • Chen, P.1    Cleland, D.J.2    Lovatt, S.J.3    Bassett, M.R.4
  • 2
    • 33745030937 scopus 로고    scopus 로고
    • Frost free operation of large and high rise cold storage
    • Boast M.F.G. Frost free operation of large and high rise cold storage. Proc. Inst. Refrigeration 6 (2003) 1-11
    • (2003) Proc. Inst. Refrigeration , vol.6 , pp. 1-11
    • Boast, M.F.G.1
  • 4
  • 6
    • 49749203310 scopus 로고
    • Natural convection in openings through partitions-1, vertical partitions
    • Brown W.G., and Solvason K.R. Natural convection in openings through partitions-1, vertical partitions. Int. J. Heat Mass Transfer 5 (1963) 859-868
    • (1963) Int. J. Heat Mass Transfer , vol.5 , pp. 859-868
    • Brown, W.G.1    Solvason, K.R.2
  • 7
    • 0005135695 scopus 로고
    • Kälteverluste durch Kühlraumöffnungen
    • Tamm W. Kälteverluste durch Kühlraumöffnungen. Kältetechnik-Klimatisierung 18 (1966) 142-144
    • (1966) Kältetechnik-Klimatisierung , vol.18 , pp. 142-144
    • Tamm, W.1
  • 8
    • 0001630414 scopus 로고
    • Neue Messungen zur Bestimmung der Kälteverluste an Kühlraumtüren
    • Fritzsche C., and Lilienblum W. Neue Messungen zur Bestimmung der Kälteverluste an Kühlraumtüren. Kältetechnik-Klimatisierung 20 (1968) 279-286
    • (1968) Kältetechnik-Klimatisierung , vol.20 , pp. 279-286
    • Fritzsche, C.1    Lilienblum, W.2
  • 9
    • 0005134970 scopus 로고
    • Heat and enthalpy gains through cold room doorways
    • Gosney W.B., and Olama H.A.L. Heat and enthalpy gains through cold room doorways. Proc. Inst. Refrigeration 72 (1975) 31-41
    • (1975) Proc. Inst. Refrigeration , vol.72 , pp. 31-41
    • Gosney, W.B.1    Olama, H.A.L.2
  • 10
    • 0020905551 scopus 로고
    • Latent loads in low humidity rooms due to moisture
    • Jones B.W., Beck B.T., and Steele J.P. Latent loads in low humidity rooms due to moisture. ASHRAE Trans. 89 (1983) 35-55
    • (1983) ASHRAE Trans. , vol.89 , pp. 35-55
    • Jones, B.W.1    Beck, B.T.2    Steele, J.P.3
  • 13
    • 85041934397 scopus 로고
    • Elsevier Scientific Publishing Company, The Netherlands
    • Rajaratnam N. Turbulent Jets (1976), Elsevier Scientific Publishing Company, The Netherlands
    • (1976) Turbulent Jets
    • Rajaratnam, N.1
  • 15
    • 0012569025 scopus 로고
    • Heat transfer characteristics of the air curtain
    • Hayes F.C., and Stoecker W.F. Heat transfer characteristics of the air curtain. ASHRAE Trans. 2120 (1969) 153-167
    • (1969) ASHRAE Trans. , vol.2120 , pp. 153-167
    • Hayes, F.C.1    Stoecker, W.F.2
  • 16
    • 0012569025 scopus 로고
    • Design data for air curtains
    • Hayes F.C., and Stoecker W.F. Design data for air curtains. ASHRAE Trans. 2121 (1969) 168-180
    • (1969) ASHRAE Trans. , vol.2121 , pp. 168-180
    • Hayes, F.C.1    Stoecker, W.F.2
  • 17
    • 0344891375 scopus 로고    scopus 로고
    • Design of air curtains used for area confinement in tunnel
    • Guyonnaud L., Solliec C., De Virel M.D., and Rey C. Design of air curtains used for area confinement in tunnel. Exp. Fluids 28 (2000) 377-384
    • (2000) Exp. Fluids , vol.28 , pp. 377-384
    • Guyonnaud, L.1    Solliec, C.2    De Virel, M.D.3    Rey, C.4
  • 18
    • 33745019762 scopus 로고    scopus 로고
    • T. Lajos, L. Preszler, Untersuchung von Türluftschleiranlagen. Heizung, Lüftung, Klimatechnic, (1975) Teil 1:26:171-176; Teil 2:26:226-235.
  • 19
    • 0012880231 scopus 로고    scopus 로고
    • Simulation of the performance of single jet air curtains for vertical refrigerated display cabinets
    • Ge Y.T., and Tassou S.A. Simulation of the performance of single jet air curtains for vertical refrigerated display cabinets. Appl. Therm. Eng. 21 2 (2001) 201-219
    • (2001) Appl. Therm. Eng. , vol.21 , Issue.2 , pp. 201-219
    • Ge, Y.T.1    Tassou, S.A.2
  • 20
    • 0036883620 scopus 로고    scopus 로고
    • Measurement and prediction of air movement through doorways in refrigerated rooms
    • Foster A.M., Barrett R., James S.J., and Swain M.J. Measurement and prediction of air movement through doorways in refrigerated rooms. Int. J. Refrigeration 25 (2002) 1102-1109
    • (2002) Int. J. Refrigeration , vol.25 , pp. 1102-1109
    • Foster, A.M.1    Barrett, R.2    James, S.J.3    Swain, M.J.4
  • 21
    • 0141895139 scopus 로고    scopus 로고
    • Experimental verification of analytical and CFD predictions of infiltration through cold store entrances
    • Foster A.M., Swain M.J., Barrett R., and James S.J. Experimental verification of analytical and CFD predictions of infiltration through cold store entrances. Int. J. Refrigeration 26 (2003) 918-925
    • (2003) Int. J. Refrigeration , vol.26 , pp. 918-925
    • Foster, A.M.1    Swain, M.J.2    Barrett, R.3    James, S.J.4
  • 22
    • 33745026865 scopus 로고    scopus 로고
    • G.R. Longdill, L.F. Frazerhurst, L.G. Wyborn, Air curtains, Report Number 385, Meat Research Institute of New Zealand (MIRINZ), 1974.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.