메뉴 건너뛰기




Volumn 51, Issue 4 I, 2004, Pages 1560-1567

Precision lead tungstate crystal calorimeter for CMS at LHC

Author keywords

Calorimeter; Crystal; Lead tungstate; Monitoring; Radiation damage; Scintillator

Indexed keywords

COMPACT MUON SOLENOIDS (CMS); ELECTROMAGNETIC CALORIMETER (ECAL); LARGE HADRON COLLIDER (LHC); LEAD TUNGSTATE;

EID: 4444379035     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2004.832804     Document Type: Conference Paper
Times cited : (19)

References (11)
  • 2
    • 4444311196 scopus 로고    scopus 로고
    • Quality of mass produced lead tungstate crystals
    • Paper N5-6. to be published in IEEE Trans. Nucl. Sci.
    • R. H. Mao, L. Y. Zhang. and R. Y. Zhu, "Quality of mass produced lead tungstate crystals," in 2003 IEEE Nuclear Science Symp. Conf. Rec., Paper N5-6. to be published in IEEE Trans. Nucl. Sci..
    • 2003 IEEE Nuclear Science Symp. Conf. Rec.
    • Mao, R.H.1    Zhang, L.Y.2    Zhu, R.Y.3
  • 3
    • 0032140479 scopus 로고    scopus 로고
    • Radiation damage in scintillating crystals
    • R. Y. Zhu, "Radiation damage in scintillating crystals," Nucl. Instrum. Methods, vol. A413. pp. 297-311, 1998.
    • (1998) Nucl. Instrum. Methods , vol.A413 , pp. 297-311
    • Zhu, R.Y.1
  • 4
    • 4444288041 scopus 로고    scopus 로고
    • Absolute calibration of electromagnetic calorimeter at LHC with physics processes
    • R. Y. Zhu, Ed.
    • T. Hu, L. Xia, and R. Y. Zhu, "Absolute calibration of electromagnetic calorimeter at LHC with physics processes," in Proc. 10th Int. Conf. Calorimetry in Particle Physics, R. Y. Zhu, Ed., 2002, pp. 459-468.
    • (2002) Proc. 10th Int. Conf. Calorimetry in Particle Physics , pp. 459-468
    • Hu, T.1    Xia, L.2    Zhu, R.Y.3
  • 6
    • 4444282503 scopus 로고
    • The LHC Study Group, CERN/AC/95-05, Oct.
    • "The LHC Conceptual Design Rep.," The LHC Study Group, CERN/AC/95-05, vol. 46, Oct. 1995.
    • (1995) The LHC Conceptual Design Rep. , vol.46
  • 7
    • 0034452314 scopus 로고    scopus 로고
    • Radiation induced color centers and light monitoring for lead tungstate crystals
    • X. D. Qu, L. Y. Zhang, and R. Y. Zhu, "Radiation induced color centers and light monitoring for lead tungstate crystals," IEEE Trans. Nucl. Sci., vol. V47, pp. 1741-1747, 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.V47 , pp. 1741-1747
    • Qu, X.D.1    Zhang, L.Y.2    Zhu, R.Y.3
  • 8
    • 0035355223 scopus 로고    scopus 로고
    • Monitoring light source for CMS lead tungstate crystal calorimeter at LHC
    • L. Y. Zhang, K. J. Zhu, R. Y. Zhu, and D. T. Liu, "Monitoring light source for CMS lead tungstate crystal calorimeter at LHC," IEEE Trans. Nucl. Sci., vol. V48, pp. 372-378, 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.V48 , pp. 372-378
    • Zhang, L.Y.1    Zhu, K.J.2    Zhu, R.Y.3    Liu, D.T.4
  • 11
    • 0032137236 scopus 로고    scopus 로고
    • Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter
    • E. Auffray, P. Baillon, D. Barney, G. Bassompierre, Y. Benhammou, and A. Blik et al., "Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter." Nucl. Instrum. Methods. vol. A412, pp. 223-237, 1998.
    • (1998) Nucl. Instrum. Methods , vol.A412 , pp. 223-237
    • Auffray, E.1    Baillon, P.2    Barney, D.3    Bassompierre, G.4    Benhammou, Y.5    Blik, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.