메뉴 건너뛰기




Volumn 71, Issue 4, 2004, Pages 336-341

Occupational asthma in the furniture industry: Is it due to styrene?

Author keywords

Asthma; Occupational asthma; Styrene

Indexed keywords

METHACHOLINE; STYRENE;

EID: 4444352579     PISSN: 00257931     EISSN: None     Source Type: Journal    
DOI: 10.1159/000079636     Document Type: Article
Times cited : (7)

References (14)
  • 1
    • 0026659624 scopus 로고
    • Occupational asthma
    • Bernstein D: Occupational asthma. Med Clin North Am 1992;76:917-935.
    • (1992) Med Clin North Am , vol.76 , pp. 917-935
    • Bernstein, D.1
  • 2
    • 0028210546 scopus 로고
    • Definition and diagnosis of occupational asthma
    • Cartier A: Definition and diagnosis of occupational asthma. Eur Respir J 1994;7:153-160.
    • (1994) Eur Respir J , vol.7 , pp. 153-160
    • Cartier, A.1
  • 6
    • 0022647544 scopus 로고
    • Effect of nifedipine on hyper-reactive bronchial responses to methacholine
    • Moscato G, Danno P, Darigo N, Dellabianca A, Candura F: Effect of nifedipine on hyper-reactive bronchial responses to methacholine. Ann Allergy 1986;56:145-149.
    • (1986) Ann Allergy , vol.56 , pp. 145-149
    • Moscato, G.1    Danno, P.2    Darigo, N.3    Dellabianca, A.4    Candura, F.5
  • 7
    • 0018343629 scopus 로고
    • Nonspecific bronchial reactivity in occupational asthma
    • Lam S, Wang R, Chan Yeung M: Nonspecific bronchial reactivity in occupational asthma. J Allergy Clin Immunol 1979;63:28-34.
    • (1979) J Allergy Clin Immunol , vol.63 , pp. 28-34
    • Lam, S.1    Wang, R.2    Chan Yeung, M.3
  • 8
    • 0031446480 scopus 로고    scopus 로고
    • Inhalation challenges with agents causing occupational asthma
    • Vandenplas O, Malo JL: Inhalation challenges with agents causing occupational asthma. Eur Respir J 1997;10:2612-2629.
    • (1997) Eur Respir J , vol.10 , pp. 2612-2629
    • Vandenplas, O.1    Malo, J.L.2
  • 9
    • 0025860594 scopus 로고
    • Peak expiratory flow rates in possible occupational asthma
    • Liss G, Tarlo S: Peak expiratory flow rates in possible occupational asthma. Chest 1991;100:63-69.
    • (1991) Chest , vol.100 , pp. 63-69
    • Liss, G.1    Tarlo, S.2
  • 11
    • 0033146518 scopus 로고    scopus 로고
    • Highlights of the Canadian Thoracic Society Guidelines for occupational asthma
    • Tarlo SM, Liss G: Highlights of the Canadian Thoracic Society Guidelines for occupational asthma. Can Fam Physician 1999;45:1541-1544.
    • (1999) Can Fam Physician , vol.45 , pp. 1541-1544
    • Tarlo, S.M.1    Liss, G.2
  • 12
    • 0027716968 scopus 로고
    • How many times per day should peak expiratory flow rates be assessed when investigating occupational asthma?
    • Malo JL, Cote J, Cartier A, Boulet LP, L'Archeveque J, Chan-Yeung M: How many times per day should peak expiratory flow rates be assessed when investigating occupational asthma? Thorax 1993;48:1211-1217.
    • (1993) Thorax , vol.48 , pp. 1211-1217
    • Malo, J.L.1    Cote, J.2    Cartier, A.3    Boulet, L.P.4    L'Archeveque, J.5    Chan-Yeung, M.6
  • 14
    • 0029952706 scopus 로고    scopus 로고
    • The development of OASYS-2: A system for the analysis of serial measurement of peak expiratory flow in workers with suspected occupational asthma
    • Gannon PF, Newton DT, Belcher J, Pantin CF, Burge PS: The development of OASYS-2: A system for the analysis of serial measurement of peak expiratory flow in workers with suspected occupational asthma. Thorax 1996;51:484-489.
    • (1996) Thorax , vol.51 , pp. 484-489
    • Gannon, P.F.1    Newton, D.T.2    Belcher, J.3    Pantin, C.F.4    Burge, P.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.