1
-
-
0037236215
-
Variant Creutzfeldt-Jakob disease and disposable anaesthetic equipment-balancing the risks [Editorial]
-
Blunt M.C., Burchett K.R. Variant Creutzfeldt-Jakob disease and disposable anaesthetic equipment-balancing the risks [Editorial]. Br J Anaesth. 90:2003;1-3
-
(2003)
Br J Anaesth
, vol.90
, pp. 1-3
-
-
Blunt, M.C.1
Burchett, K.R.2
-
2
-
-
0033573778
-
Investigation of variant Creutzfeldt-Jakob disease and other human prion diseases with tonsil biopsy samples
-
Hill A.F., Butterworth R.J., Joiner S., Jackson G., Rossor M.N., Thomas D.J., et al. Investigation of variant Creutzfeldt-Jakob disease and other human prion diseases with tonsil biopsy samples. Lancet. 353:1999;183-189
-
(1999)
Lancet
, vol.353
, pp. 183-189
-
-
Hill, A.F.1
Butterworth, R.J.2
Joiner, S.3
Jackson, G.4
Rossor, M.N.5
Thomas, D.J.6
-
3
-
-
0027193446
-
Microbial adherence to and disinfection of laryngoscopes used in office practice
-
Abramson A.L., Gilberto E., Mullooly V., France K., Alperstein P., Isenberg H.D. Microbial adherence to and disinfection of laryngoscopes used in office practice. Laryngoscope. 103:1993;503-508
-
(1993)
Laryngoscope
, vol.103
, pp. 503-508
-
-
Abramson, A.L.1
Gilberto, E.2
Mullooly, V.3
France, K.4
Alperstein, P.5
Isenberg, H.D.6
-
5
-
-
0035071690
-
Evaluation of the disposable Vital View laryngoscope apparatus
-
Asai T., Uchiyama Y., Yamamoto K., Johmura S., Shingu K. Evaluation of the disposable Vital View laryngoscope apparatus. Anaesthesia. 56:2001;342-345
-
(2001)
Anaesthesia
, vol.56
, pp. 342-345
-
-
Asai, T.1
Uchiyama, Y.2
Yamamoto, K.3
Johmura, S.4
Shingu, K.5
-
6
-
-
0037234352
-
Randomized evaluation of the performance of single-use laryngoscopes in simulated easy and difficult intubation
-
Twigg S.J., McCormick B., Cook T.M. Randomized evaluation of the performance of single-use laryngoscopes in simulated easy and difficult intubation. Br J Anaesth. 90:2003;8-13
-
(2003)
Br J Anaesth
, vol.90
, pp. 8-13
-
-
Twigg, S.J.1
McCormick, B.2
Cook, T.M.3
-
7
-
-
0033124685
-
Laryngoscope. Évaluation d'un dispositif de prévention de la contamination des lames
-
Bazin J.E., Sifreu A., Traore O., Laveran H., Schoeffler P. Laryngoscope. Évaluation d'un dispositif de prévention de la contamination des lames. Ann Fr Anesth Réanim. 18:1999;499-502
-
(1999)
Ann Fr Anesth Réanim
, vol.18
, pp. 499-502
-
-
Bazin, J.E.1
Sifreu, A.2
Traore, O.3
Laveran, H.4
Schoeffler, P.5
-
8
-
-
4444378613
-
-
o DGS/5C/DHOS/E2/2001/139 du 14 mars 2001.
-
o DGS/5C/DHOS/E2/2001/139 du 14 mars 2001.
-
-
-
-
9
-
-
0034762389
-
Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment
-
Miller D.M., Youkhana I., Karunaratne W.U., Pearce A. Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment. Anaesthesia. 56:2001;1069-1072
-
(2001)
Anaesthesia
, vol.56
, pp. 1069-1072
-
-
Miller, D.M.1
Youkhana, I.2
Karunaratne, W.U.3
Pearce, A.4
-
10
-
-
0032834770
-
The effect of steam sterilisation at 134 degrees C on light intensity provided by fibrelight Macintosh laryngoscopes
-
Bucx M.J., Veldman D.J., Beenhakker M.M., Koster R. The effect of steam sterilisation at 134 degrees C on light intensity provided by fibrelight Macintosh laryngoscopes. Anaesthesia. 54:1999;875-878
-
(1999)
Anaesthesia
, vol.54
, pp. 875-878
-
-
Bucx, M.J.1
Veldman, D.J.2
Beenhakker, M.M.3
Koster, R.4
-
11
-
-
0036054785
-
Disposable laryngoscope blades
-
Babb M., Mann S., Babb S. Disposable laryngoscope blades. Anaesthesia. 57:2002;286-288
-
(2002)
Anaesthesia
, vol.57
, pp. 286-288
-
-
Babb, M.1
Mann, S.2
Babb, S.3
-
12
-
-
0035984344
-
Re-useable and sheathed laryngoscope blades
-
Cook T.M., McCormick B., Twigg S. Re-useable and sheathed laryngoscope blades. Anaesthesia. 57:2002;823-824
-
(2002)
Anaesthesia
, vol.57
, pp. 823-824
-
-
Cook, T.M.1
McCormick, B.2
Twigg, S.3
-
13
-
-
4444247189
-
Déformation des lames de laryngoscopes à usage unique lors de charge mécanique [Résumé]
-
Montravers P., Rezzoug A., Verton C., Germain J.L. Déformation des lames de laryngoscopes à usage unique lors de charge mécanique [Résumé]. Ann Fr Anesth Réanim. 21:(Suppl 2):2002;288S
-
(2002)
Ann Fr Anesth Réanim
, vol.21
, Issue.SUPPL. 2
-
-
Montravers, P.1
Rezzoug, A.2
Verton, C.3
Germain, J.L.4
-
14
-
-
0028357626
-
The airway: Problems and predictions in 18,500 patients
-
Rose K., Cohen M.M. The airway: problems and predictions in 18,500 patients. Can J Anaesth. 41:1994;372-383
-
(1994)
Can J Anaesth
, vol.41
, pp. 372-383
-
-
Rose, K.1
Cohen, M.M.2
-
15
-
-
0042347783
-
Difficult tracheal intubation is more common in obese than in lean patients
-
Juvin P., Lavaut E., Dupont H., Lefevre P., Demetriou M., Dumoulin J.L., et al. Difficult tracheal intubation is more common in obese than in lean patients. Anesth Analg. 97:2003;595-600
-
(2003)
Anesth Analg
, vol.97
, pp. 595-600
-
-
Juvin, P.1
Lavaut, E.2
Dupont, H.3
Lefevre, P.4
Demetriou, M.5
Dumoulin, J.L.6
-
16
-
-
0031157584
-
Incidence of visible and occult blood on laryngoscope blades and handles
-
Phillips R.A., Monaghan W.P. Incidence of visible and occult blood on laryngoscope blades and handles. AANA J. 65:1997;241-246
-
(1997)
AANA J
, vol.65
, pp. 241-246
-
-
Phillips, R.A.1
Monaghan, W.P.2
-
17
-
-
0034198525
-
Laryngoscope handles: A potential for infection
-
Simmons S.A. Laryngoscope handles: a potential for infection. AANA J. 68:2000;233-236
-
(2000)
AANA J
, vol.68
, pp. 233-236
-
-
Simmons, S.A.1
-
18
-
-
0041847349
-
B. B. Lames à usage unique, aspects économiques
-
Maroudy D. B. B. Lames à usage unique, aspects économiques. Oxymag. 53:2000;11-12
-
(2000)
Oxymag
, vol.53
, pp. 11-12
-
-
Maroudy, D.1
|