Volumn 54, Issue 9, 1999, Pages 875-878

The effect of steam sterilisation at 134°C on light intensity provided by fibrelight Macintosh laryngoscopes

Author keywords

Equipment; laryngoscopes; Infection control; sterilisation, disinfection; Larynx; laryngoscopy

Indexed keywords

ANESTHETIC EQUIPMENT; ARTICLE; FIBER OPTICS; INSTRUMENT STERILIZATION; LARYNGOSCOPE; LIGHT; MEASUREMENT; TEMPERATURE; WATER VAPOR;

EID: 0032834770     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2044.1999.00948.x     Document Type: Article
Times cited : (24)

References (7)
  • 2
    • 0028213773 scopus 로고
    • A survey of laryngoscope contamination at a university and a community hospital
    • Morell RC, Ririe D, James R. A survey of laryngoscope contamination at a university and a community hospital. Anesthesiology 1994; 80: 960.
    • (1994) Anesthesiology , vol.80 , pp. 960
    • Morell, R.C.1    Ririe, D.2    James, R.3
  • 4
    • 0028951337 scopus 로고
    • Preventing perioperative transmission offection: A survey of anesthesiology practice
    • Tait AR, Tuttle DB. Preventing perioperative transmission offection: a survey of anesthesiology practice. Anesthesia and Analgesia 1995; 80: 764-9.
    • (1995) Anesthesia and Analgesia , vol.80 , pp. 764-769
    • Tait, A.R.1    Tuttle, D.B.2
  • 5
    • 0030041308 scopus 로고    scopus 로고
    • Infection control precautions and anesthesia
    • Arron BL. Infection control precautions and anesthesia. Anesthesia and Analgesia 1996; 82: 427-8.
    • (1996) Anesthesia and Analgesia , vol.82 , pp. 427-428
    • Arron, B.L.1
  • 6
    • 0028146316 scopus 로고
    • Prevention of accupational transmission of human immunodeficiency virus and hepatitis B virus among anesthesiologists: A survey of anesthesiology practice
    • Tait AR, Tuttle DB. Prevention of accupational transmission of human immunodeficiency virus and hepatitis B virus among anesthesiologists: a survey of anesthesiology practice. Anesthesia and Analgesia 1994; 79: 623-8.
    • (1994) Anesthesia and Analgesia , vol.79 , pp. 623-628
    • Tait, A.R.1    Tuttle, D.B.2
  • 7
    • 0029285835 scopus 로고
    • The laryngoscope as a potential source of cross infection
    • Foweraker E. The laryngoscope as a potential source of cross infection. Journal of Hospital Infection 1995; 29: 315-16.
    • (1995) Journal of Hospital Infection , vol.29 , pp. 315-316
    • Foweraker, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.