메뉴 건너뛰기




Volumn 74, Issue 4, 2004, Pages 450-453

An evaluation of slot size in orthodontic brackets - Are Standards as expected?

Author keywords

Bracket slot tolerance; Machining accuracy; Slot geometry

Indexed keywords

ARTICLE; EVALUATION; GEOMETRY; INCISOR; ORTHODONTIC DEVICE; ORTHODONTICS; STANDARD;

EID: 4444312845     PISSN: 00033219     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (93)

References (14)
  • 1
    • 0035489099 scopus 로고    scopus 로고
    • Orthodontic slot size: It's time to retool
    • Peck S. Orthodontic slot size: it's time to retool. Angle Orthod. 2001;71:329-330.
    • (2001) Angle Orthod , vol.71 , pp. 329-330
    • Peck, S.1
  • 2
    • 2942602470 scopus 로고    scopus 로고
    • A plea for agreement
    • Rubin R. A plea for agreement. Angle Orthod. 2001;71:156.
    • (2001) Angle Orthod , vol.71 , pp. 156
    • Rubin, R.1
  • 4
    • 0031129525 scopus 로고    scopus 로고
    • Scanning electron microscopy evaluation of the interfacial fit of interchanged components of four dental implant systems
    • Dellow A, Driessen C, Nel H. Scanning electron microscopy evaluation of the interfacial fit of interchanged components of four dental implant systems. Int J Prosthod. 1997;10:216-221.
    • (1997) Int J Prosthod , vol.10 , pp. 216-221
    • Dellow, A.1    Driessen, C.2    Nel, H.3
  • 5
    • 0030154871 scopus 로고    scopus 로고
    • Marginal fit of electroformed ceramometal crowns
    • Holmes J, Pilcher E, Rivers J, Stewart R. Marginal fit of electroformed ceramometal crowns. J Prosthod. 1996;5:111-114.
    • (1996) J Prosthod , vol.5 , pp. 111-114
    • Holmes, J.1    Pilcher, E.2    Rivers, J.3    Stewart, R.4
  • 6
    • 0027620312 scopus 로고
    • The fit of Procera titanium crowns: An in vitro and clinical study
    • Karlsson S. The fit of Procera titanium crowns: an in vitro and clinical study. Acta Odontol Scand. 1993;51:129-134.
    • (1993) Acta Odontol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 7
    • 0036133921 scopus 로고    scopus 로고
    • Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro
    • Addi S, Hedayati-Khams A, Poya A, Sjogren G. Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro. J Dent. 2002;30:53-58.
    • (2002) J Dent , vol.30 , pp. 53-58
    • Addi, S.1    Hedayati-Khams, A.2    Poya, A.3    Sjogren, G.4
  • 8
    • 0033071557 scopus 로고    scopus 로고
    • Assessment of second-order clearances between orthodontic archwires and bracket slots via the critical contact angle for binding
    • Kusy R, Whitley J. Assessment of second-order clearances between orthodontic archwires and bracket slots via the critical contact angle for binding. Angle Orthod. 1999;69:71-80.
    • (1999) Angle Orthod , vol.69 , pp. 71-80
    • Kusy, R.1    Whitley, J.2
  • 9
    • 0033186442 scopus 로고    scopus 로고
    • Loss of anterior torque control due to variations in bracket slot and archwire dimensions
    • Siatkowski R. Loss of anterior torque control due to variations in bracket slot and archwire dimensions. J Clin Orthod. 1999;33:508-510.
    • (1999) J Clin Orthod , vol.33 , pp. 508-510
    • Siatkowski, R.1
  • 10
    • 0033192523 scopus 로고    scopus 로고
    • Comparison of load transmission and bracket deformation between titanium and stainless steel brackets
    • Kapur R, Sinha P, Nanda R. Comparison of load transmission and bracket deformation between titanium and stainless steel brackets. Am J Orthod Dentofacial Orthop. 1999;116:275-278.
    • (1999) Am J Orthod Dentofacial Orthop , vol.116 , pp. 275-278
    • Kapur, R.1    Sinha, P.2    Nanda, R.3
  • 11
    • 0036011429 scopus 로고    scopus 로고
    • Torque capacity of metal and plastic brackets with reference to materials, application, technology and biomechanics
    • Gmyrek H, Bourauel C, Richter G, Harzer W. Torque capacity of metal and plastic brackets with reference to materials, application, technology and biomechanics. J Orofac Orthop. 2002;63:113-128.
    • (2002) J Orofac Orthop , vol.63 , pp. 113-128
    • Gmyrek, H.1    Bourauel, C.2    Richter, G.3    Harzer, W.4
  • 12
    • 0032066469 scopus 로고    scopus 로고
    • On the variability of cross-sectional dimensions and torsional properties of rectangular nickel-titanium arch wires
    • Meling T, Ødegaard J. On the variability of cross-sectional dimensions and torsional properties of rectangular nickel-titanium arch wires. Am J Dentofacial Orthop. 1998;113:546-557.
    • (1998) Am J Dentofacial Orthop , vol.113 , pp. 546-557
    • Meling, T.1    Ødegaard, J.2
  • 13
    • 0037264357 scopus 로고    scopus 로고
    • Three-dimensional relationship between the critical contact angle and the torque angle
    • Kang B, Baek S, Mah J, Yang W. Three-dimensional relationship between the critical contact angle and the torque angle. Am J Orthod Dentofacial Orthop. 2003;123:64-73.
    • (2003) Am J Orthod Dentofacial Orthop , vol.123 , pp. 64-73
    • Kang, B.1    Baek, S.2    Mah, J.3    Yang, W.4
  • 14
    • 0033649416 scopus 로고    scopus 로고
    • Torque transmission between square wire and bracket as a function of measurement, form and hardness parameters
    • Fischer-Brandies H, Orthuber W, Es-Souni M, Meyer S. Torque transmission between square wire and bracket as a function of measurement, form and hardness parameters. J Orofac Orthop. 2000;61:258-265.
    • (2000) J Orofac Orthop , vol.61 , pp. 258-265
    • Fischer-Brandies, H.1    Orthuber, W.2    Es-Souni, M.3    Meyer, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.