메뉴 건너뛰기




Volumn 35, Issue 1, 2008, Pages 39-43

Corneal thickness in pigs measured by ultrasound pachymetry in vivo

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; CORNEA TRANSPLANTATION; ECHOGRAPHY; FEMALE; GENERAL ANESTHESIA; IN VIVO STUDY; MEASUREMENT; NONHUMAN; SWINE; XENOTRANSPLANTATION;

EID: 44149105666     PISSN: 09013393     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (65)

References (20)
  • 1
    • 0035320504 scopus 로고    scopus 로고
    • Density of corneal endothelial cells and corneal thickness in eyes of euthanatized horses
    • Andrew S E, D T Ramsey, J G Hauptman & D E Brooks. Density of corneal endothelial cells and corneal thickness in eyes of euthanatized horses. Am J Vet Res. 2001, 62, 479-482.
    • (2001) Am J Vet Res , vol.62 , pp. 479-482
    • Andrew, S.E.1    Ramsey, D.T.2    Hauptman, J.G.3    Brooks, D.E.4
  • 2
    • 0036521193 scopus 로고    scopus 로고
    • Density of corneal endothelial cells, corneal thickness, and corneal diameters in normal eyes of llamas and alpacas
    • Andrew S E, A M Willis & D E Anderson. Density of corneal endothelial cells, corneal thickness, and corneal diameters in normal eyes of llamas and alpacas. Am J Vet Res. 2002, 63, 326-329.
    • (2002) Am J Vet Res , vol.63 , pp. 326-329
    • Andrew, S.E.1    Willis, A.M.2    Anderson, D.E.3
  • 4
    • 0842326971 scopus 로고    scopus 로고
    • Continuous non-contact corneal pachymetry with a high speed reflectometer
    • Bohnke M, P Chavanne, R Gianotti & R P Salathe. Continuous non-contact corneal pachymetry with a high speed reflectometer. J Refract Surg. 1998, 14, 140-146.
    • (1998) J Refract Surg , vol.14 , pp. 140-146
    • Bohnke, M.1    Chavanne, P.2    Gianotti, R.3    Salathe, R.P.4
  • 5
    • 0020546449 scopus 로고
    • Corneal thickness profiles in rabbits using an ultrasonic pachometer
    • Chan T, S Payor & B A Holden. Corneal thickness profiles in rabbits using an ultrasonic pachometer. Invest Ophthalmol Vis Sci. 1983, 24, 1408-1410.
    • (1983) Invest Ophthalmol Vis Sci , vol.24 , pp. 1408-1410
    • Chan, T.1    Payor, S.2    Holden, B.A.3
  • 6
    • 28444453721 scopus 로고    scopus 로고
    • Current advances in xenotrans-plantation
    • Cox A & R Zhong. Current advances in xenotrans-plantation. Hepatobiliary Pancreat Dis Int. 2005, 4, 490-494.
    • (2005) Hepatobiliary Pancreat Dis Int , vol.4 , pp. 490-494
    • Cox, A.1    Zhong, R.2
  • 7
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty M J & M L Zaman. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000, 44, 367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 8
    • 2442674323 scopus 로고    scopus 로고
    • Corneal transplantation: The forgotten graft
    • George A J & D F Larkin. Corneal transplantation: the forgotten graft. Am J Transplant. 2004, 4, 678-685.
    • (2004) Am J Transplant , vol.4 , pp. 678-685
    • George, A.J.1    Larkin, D.F.2
  • 11
    • 0020045007 scopus 로고
    • Decrease in canine corneal endothelial cell density and increase in corneal thickness as functions of age
    • Gwin R M, I Lerner, J K Warren & G Gum. Decrease in canine corneal endothelial cell density and increase in corneal thickness as functions of age. Invest Ophthalmol Vis Sci. 1982, 22, 267-271.
    • (1982) Invest Ophthalmol Vis Sci , vol.22 , pp. 267-271
    • Gwin, R.M.1    Lerner, I.2    Warren, J.K.3    Gum, G.4
  • 12
    • 1342321932 scopus 로고    scopus 로고
    • Postnatal development of central corneal thickness in chicks of Gallus gallus domesticus
    • Montiani-Ferreira F, F Cardoso & S Petersen-Jones. Postnatal development of central corneal thickness in chicks of Gallus gallus domesticus. Vet Ophthalmol. 2004, 7, 37-39.
    • (2004) Vet Ophthalmol , vol.7 , pp. 37-39
    • Montiani-Ferreira, F.1    Cardoso, F.2    Petersen-Jones, S.3
  • 14
    • 0037501114 scopus 로고    scopus 로고
    • Assessment of corneal thickness, intraocular pressure, optical corneal diameter, and axial globe dimensions in Miniature Horses
    • Plummer C E, D T Ramsey & J G Hauptman. Assessment of corneal thickness, intraocular pressure, optical corneal diameter, and axial globe dimensions in Miniature Horses. Am J Vet Res. 2003, 64, 661-665.
    • (2003) Am J Vet Res , vol.64 , pp. 661-665
    • Plummer, C.E.1    Ramsey, D.T.2    Hauptman, J.G.3
  • 15
    • 0033206003 scopus 로고    scopus 로고
    • Corneal thickness, intraocular pressure, and optical corneal diameter in Rocky Mountain Horses with cornea globosa or clinically normal corneas
    • Ramsey D T, J G Hauptman & S M Petersen-Jones. Corneal thickness, intraocular pressure, and optical corneal diameter in Rocky Mountain Horses with cornea globosa or clinically normal corneas. Am J Vet Res. 1999, 60, 1317-1321.
    • (1999) Am J Vet Res , vol.60 , pp. 1317-1321
    • Ramsey, D.T.1    Hauptman, J.G.2    Petersen-Jones, S.M.3
  • 16
    • 33846286531 scopus 로고    scopus 로고
    • Progress in xenotransplantation following the introduction of gene-knockout technology
    • Tai H C, M Ezzelarab, H Hara, D Ayares & D K Cooper. Progress in xenotransplantation following the introduction of gene-knockout technology. Transpl Int. 2007, 20, 107-117.
    • (2007) Transpl Int , vol.20 , pp. 107-117
    • Tai, H.C.1    Ezzelarab, M.2    Hara, H.3    Ayares, D.4    Cooper, D.K.5
  • 17
    • 0028895933 scopus 로고
    • Effect of auriculopalpebral nerve block and intravenous administration of xylazine on intraocular pressure and corneal thickness in horses
    • van der Woerdt A, B C Gilger, D A Wilkie & S M Strauch. Effect of auriculopalpebral nerve block and intravenous administration of xylazine on intraocular pressure and corneal thickness in horses. Am J Vet Res. 1995, 56, 155-158.
    • (1995) Am J Vet Res , vol.56 , pp. 155-158
    • van der Woerdt, A.1    Gilger, B.C.2    Wilkie, D.A.3    Strauch, S.M.4
  • 18
  • 19
    • 0026507928 scopus 로고
    • Precision of lenticular thickness in relation to full stroma corneal thickness. Experimental results with the lamellar microkeratome]
    • Wilmes C, J Draeger & M Kohlhaas. [Precision of lenticular thickness in relation to full stroma corneal thickness. Experimental results with the lamellar microkeratome]. Ophthalmologe. 1992, 89, 147-150.
    • (1992) Ophthalmologe , vol.89 , pp. 147-150
    • Wilmes, C.1    Draeger, J.2    Kohlhaas, M.3
  • 20
    • 33845609235 scopus 로고    scopus 로고
    • Gal knockout and beyond
    • Zhong R. Gal knockout and beyond. Am J Transplant. 2007, 7, 5-11.
    • (2007) Am J Transplant , vol.7 , pp. 5-11
    • Zhong, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.