1
-
-
0031003645
-
Outcome of tunneled hemodialysis catheters placed via the right internal jugular vein by interventional radiologists
-
Trerotola S.O., Johnson M.S., Harris V.J., et al. Outcome of tunneled hemodialysis catheters placed via the right internal jugular vein by interventional radiologists. Radiology 203 (1997) 489-495
-
(1997)
Radiology
, vol.203
, pp. 489-495
-
-
Trerotola, S.O.1
Johnson, M.S.2
Harris, V.J.3
-
2
-
-
0030070147
-
Outcome of tunneled hemodialysis catheters placed by radiologists
-
Lund G.B., Trerotola S.O., Scheel Jr. P.F., et al. Outcome of tunneled hemodialysis catheters placed by radiologists. Radiology 198 (1996) 467-472
-
(1996)
Radiology
, vol.198
, pp. 467-472
-
-
Lund, G.B.1
Trerotola, S.O.2
Scheel Jr., P.F.3
-
3
-
-
0035127251
-
Comparison of cuffed tunneled hemodialysis catheter survival
-
Rocklin M.A., Dwight C.A., Callen L.J., Bispham B.Z., and Spiegel D.M. Comparison of cuffed tunneled hemodialysis catheter survival. Am J Kidney Dis 37 (2001) 557-563
-
(2001)
Am J Kidney Dis
, vol.37
, pp. 557-563
-
-
Rocklin, M.A.1
Dwight, C.A.2
Callen, L.J.3
Bispham, B.Z.4
Spiegel, D.M.5
-
4
-
-
0033009068
-
Exchange of poorly functioning tunneled permanent hemodialysis catheters
-
Garofalo R.S., Zaleski G.X., Lorenz J.M., Funaki B., Rosenblum J.D., and Leef J.A. Exchange of poorly functioning tunneled permanent hemodialysis catheters. AJR Am J Roentgenol 173 (1999) 155-158
-
(1999)
AJR Am J Roentgenol
, vol.173
, pp. 155-158
-
-
Garofalo, R.S.1
Zaleski, G.X.2
Lorenz, J.M.3
Funaki, B.4
Rosenblum, J.D.5
Leef, J.A.6
-
5
-
-
0345367419
-
Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: a comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges
-
Duszak Jr. R., Haskal Z.J., Thomas-Hawkins C., et al. Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: a comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges. J Vasc Interv Radiol 9 (1998) 321-327
-
(1998)
J Vasc Interv Radiol
, vol.9
, pp. 321-327
-
-
Duszak Jr., R.1
Haskal, Z.J.2
Thomas-Hawkins, C.3
-
6
-
-
0030928646
-
A technique for inserting inadvertently removed tunneled hemodialysis catheters using existing subcutaneous tracts
-
Lin B.H., Funaki B., and Szymski G.X. A technique for inserting inadvertently removed tunneled hemodialysis catheters using existing subcutaneous tracts. AJR Am J Roentgenol 169 (1997) 1157-1158
-
(1997)
AJR Am J Roentgenol
, vol.169
, pp. 1157-1158
-
-
Lin, B.H.1
Funaki, B.2
Szymski, G.X.3
-
7
-
-
0030828839
-
Replacement of accidentally removed tunneled venous catheters through existing subcutaneous tracts
-
Egglin T.K., Rosenblatt M., Dickey K.W., Houston J.P., and Pollak J.S. Replacement of accidentally removed tunneled venous catheters through existing subcutaneous tracts. J Vasc Interv Radiol 8 (1997) 197-202
-
(1997)
J Vasc Interv Radiol
, vol.8
, pp. 197-202
-
-
Egglin, T.K.1
Rosenblatt, M.2
Dickey, K.W.3
Houston, J.P.4
Pollak, J.S.5
-
8
-
-
0032712691
-
Reinsertion of accidentally removed tunneled central venous catheter via the existing subcutaneous tract
-
Funaki B., Lorenz J., and Zaleski G.X. Reinsertion of accidentally removed tunneled central venous catheter via the existing subcutaneous tract. Pediatr Radiol 29 (1999) 911-913
-
(1999)
Pediatr Radiol
, vol.29
, pp. 911-913
-
-
Funaki, B.1
Lorenz, J.2
Zaleski, G.X.3
-
9
-
-
0024511462
-
Radiologic placement of Hickman catheters
-
Robertson L.J., Mauro M.A., and Jaques P.F. Radiologic placement of Hickman catheters. Radiology 170 (1989) 1007-1009
-
(1989)
Radiology
, vol.170
, pp. 1007-1009
-
-
Robertson, L.J.1
Mauro, M.A.2
Jaques, P.F.3
-
10
-
-
27544468720
-
Quality improvement guidelines for central venous access
-
Lewis C.A., Allen T.E., Burke D.R., et al. Quality improvement guidelines for central venous access. J Vasc Interv Radiol 14 suppl (2003) S231-S234
-
(2003)
J Vasc Interv Radiol
, vol.14
, Issue.SUPPL
-
-
Lewis, C.A.1
Allen, T.E.2
Burke, D.R.3
-
11
-
-
2342599719
-
Retrospective assessment of risk factors to predict tunneled hemodialysis catheter outcome
-
Lee O., Raque J.D., Lee L.J., Wivell W., Block C.A., and Bettmann M.A. Retrospective assessment of risk factors to predict tunneled hemodialysis catheter outcome. J Vasc Interv Radiol 15 (2004) 457-461
-
(2004)
J Vasc Interv Radiol
, vol.15
, pp. 457-461
-
-
Lee, O.1
Raque, J.D.2
Lee, L.J.3
Wivell, W.4
Block, C.A.5
Bettmann, M.A.6
-
12
-
-
0031802118
-
Treatment of infected tunneled venous access hemodialysis catheters with guidewire exchange
-
Robinson D., Suhocki P., and Schwab S.J. Treatment of infected tunneled venous access hemodialysis catheters with guidewire exchange. Kidney Int 53 (1998) 1792-1794
-
(1998)
Kidney Int
, vol.53
, pp. 1792-1794
-
-
Robinson, D.1
Suhocki, P.2
Schwab, S.J.3
-
13
-
-
0034770506
-
Recent trends in central venous catheter placement: a comparison of interventional radiology with other specialties
-
Reeves A.R., Seshadri R., and Trerotola S.O. Recent trends in central venous catheter placement: a comparison of interventional radiology with other specialties. J Vasc Interv Radiol 12 (2001) 1211-1214
-
(2001)
J Vasc Interv Radiol
, vol.12
, pp. 1211-1214
-
-
Reeves, A.R.1
Seshadri, R.2
Trerotola, S.O.3
-
14
-
-
33748190135
-
Restoration of patency in failing tunneled hemodialysis catheters: a comparison of catheter exchange, exchange and balloon disruption of the fibrin sheath, and femoral stripping
-
d'Othee B.J., Tham J.C., and Sheiman R.G. Restoration of patency in failing tunneled hemodialysis catheters: a comparison of catheter exchange, exchange and balloon disruption of the fibrin sheath, and femoral stripping. J Vasc Interv Radiol 17 (2006) 1011-1015
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 1011-1015
-
-
d'Othee, B.J.1
Tham, J.C.2
Sheiman, R.G.3
-
15
-
-
0028568504
-
Technical report: Hickman catheter rescue
-
Brown P.W., McBride K.D., and Gaines P.A. Technical report: Hickman catheter rescue. Clin Radiol 49 (1994) 891-894
-
(1994)
Clin Radiol
, vol.49
, pp. 891-894
-
-
Brown, P.W.1
McBride, K.D.2
Gaines, P.A.3
-
16
-
-
0034038705
-
Hemodialysis catheter placement and management
-
Trerotola S.O. Hemodialysis catheter placement and management. Radiology 215 (2000) 651-658
-
(2000)
Radiology
, vol.215
, pp. 651-658
-
-
Trerotola, S.O.1
-
17
-
-
0033036544
-
Cost comparison of radiologic versus surgical placement of long-term hemodialysis catheters
-
Noh H.M., Kaufman J.A., Rhea J.T., Kim S.Y., Geller S.C., and Waltman A.C. Cost comparison of radiologic versus surgical placement of long-term hemodialysis catheters. AJR Am J Roentgenol 172 (1999) 673-675
-
(1999)
AJR Am J Roentgenol
, vol.172
, pp. 673-675
-
-
Noh, H.M.1
Kaufman, J.A.2
Rhea, J.T.3
Kim, S.Y.4
Geller, S.C.5
Waltman, A.C.6
-
18
-
-
29944445378
-
Central venous catheters: the role of radiology
-
Tan P.L., and Gibson M. Central venous catheters: the role of radiology. Clin Radiol 61 (2006) 13-22
-
(2006)
Clin Radiol
, vol.61
, pp. 13-22
-
-
Tan, P.L.1
Gibson, M.2
-
19
-
-
0034065575
-
Bacteremia associated with tunneled dialysis catheters: comparison of two treatment strategies
-
Tanriover B., Carlton D., Saddekni S., et al. Bacteremia associated with tunneled dialysis catheters: comparison of two treatment strategies. Kidney Int 57 (2000) 2151-2155
-
(2000)
Kidney Int
, vol.57
, pp. 2151-2155
-
-
Tanriover, B.1
Carlton, D.2
Saddekni, S.3
-
20
-
-
0036774564
-
Central venous catheters in home infusion care: outcomes analysis in 50,470 patients
-
Moureau N., Poole S., Murdock M.A., Gray S.M., and Semba C.P. Central venous catheters in home infusion care: outcomes analysis in 50,470 patients. J Vasc Interv Radiol 13 (2002) 1009-1016
-
(2002)
J Vasc Interv Radiol
, vol.13
, pp. 1009-1016
-
-
Moureau, N.1
Poole, S.2
Murdock, M.A.3
Gray, S.M.4
Semba, C.P.5
-
21
-
-
0032811796
-
Radiologic placement of tunneled central catheters: rates of success and of immediate complications in a large series
-
Docktor B.L., Sadler D.J., Gray R.R., Saliken J.C., and So C.B. Radiologic placement of tunneled central catheters: rates of success and of immediate complications in a large series. AJR Am J Roentgenol 173 (1999) 457-460
-
(1999)
AJR Am J Roentgenol
, vol.173
, pp. 457-460
-
-
Docktor, B.L.1
Sadler, D.J.2
Gray, R.R.3
Saliken, J.C.4
So, C.B.5
-
22
-
-
0033974019
-
Internal jugular and upper extremity central venous access in interventional radiology: is a postprocedure chest radiograph necessary?
-
Caridi J.G., West J.H., Stavropoulos S.W., and Hawkins Jr. I.F. Internal jugular and upper extremity central venous access in interventional radiology: is a postprocedure chest radiograph necessary?. AJR Am J Roentgenol 174 (2000) 363-366
-
(2000)
AJR Am J Roentgenol
, vol.174
, pp. 363-366
-
-
Caridi, J.G.1
West, J.H.2
Stavropoulos, S.W.3
Hawkins Jr., I.F.4
-
23
-
-
0031862926
-
Central venous access: low internal jugular vein approach using imaging guidance
-
Silberzweig J.E., and Mitty H.A. Central venous access: low internal jugular vein approach using imaging guidance. AJR Am J Roentgenol 170 (1998) 1617-1620
-
(1998)
AJR Am J Roentgenol
, vol.170
, pp. 1617-1620
-
-
Silberzweig, J.E.1
Mitty, H.A.2
-
24
-
-
11444251316
-
Improved results using ultrasound guidance for central venous access
-
Gann Jr. M., and Sardi A. Improved results using ultrasound guidance for central venous access. Am Surg 69 (2003) 1104-1107
-
(2003)
Am Surg
, vol.69
, pp. 1104-1107
-
-
Gann Jr., M.1
Sardi, A.2
-
25
-
-
0033779644
-
Fibrin sheath stripping versus catheter exchange for the treatment of failed tunneled hemodialysis catheters: randomized clinical trial
-
Merport M., Murphy T.P., Egglin T.K., and Dubel G.J. Fibrin sheath stripping versus catheter exchange for the treatment of failed tunneled hemodialysis catheters: randomized clinical trial. J Vasc Interv Radiol 11 (2000) 1115-1120
-
(2000)
J Vasc Interv Radiol
, vol.11
, pp. 1115-1120
-
-
Merport, M.1
Murphy, T.P.2
Egglin, T.K.3
Dubel, G.J.4
|