메뉴 건너뛰기




Volumn 36, Issue 6, 2008, Pages 1072-1077

A new four-electrode Focused Impedance Measurement (FIM) system for physiological study

Author keywords

Electrical impedance measurement; Focused admittance measurement; Focused impedance measurement

Indexed keywords

BIOLOGICAL ORGANS; ELECTRODES; MEDICAL APPLICATIONS;

EID: 43449102781     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-008-9470-7     Document Type: Article
Times cited : (27)

References (13)
  • 2
    • 0021844045 scopus 로고
    • Applied potential tomography: Possible clinical applications
    • Brown B. H., D. C. Barber, A. D. Seager. Applied potential tomography: possible clinical applications. Clin. Phys. Physiol. Meas. 6:109-121, 1985
    • (1985) Clin. Phys. Physiol. Meas. , vol.6 , pp. 109-121
    • Brown, B.H.1    Barber, D.C.2    Seager, A.D.3
  • 3
    • 0034635774 scopus 로고    scopus 로고
    • The relationship between tissue structure and imposed electrical current flow in cervical neoplasia
    • Brown B. H., J. A. Tidy, K. Boston, A. D. Blackett, R. H. Smallwood, F. Sharp. The relationship between tissue structure and imposed electrical current flow in cervical neoplasia. Lancet 355:892-895, 2000
    • (2000) Lancet , vol.355 , pp. 892-895
    • Brown, B.H.1    Tidy, J.A.2    Boston, K.3    Blackett, A.D.4    Smallwood, R.H.5    Sharp, F.6
  • 4
    • 0014986362 scopus 로고
    • An application of electrocardiographic lead theory to impedance plethysmography
    • Geselowitz D. B. An application of electrocardiographic lead theory to impedance plethysmography. IEEE Trans. Biomed. Eng. BME 18:38-41, 1971
    • (1971) IEEE Trans. Biomed. Eng. BME , vol.18 , pp. 38-41
    • Geselowitz, D.B.1
  • 5
    • 0028276263 scopus 로고
    • A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and lungs with pulmonary emboli
    • Leathard A. D., B. H. Brown, J. Campbell, F. Zhang, A. H. Morice, D. Tayler. A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and lungs with pulmonary emboli. Physiol. Meas. 15:A137-A146, 1994
    • (1994) Physiol. Meas. , vol.15
    • Leathard, A.D.1    Brown, B.H.2    Campbell, J.3    Zhang, F.4    Morice, A.H.5    Tayler, D.6
  • 7
    • 0029786452 scopus 로고
    • 3D object localisation using EIT measurements at two levels
    • Rabbani K. S., M. Hassan, A. Kiber. 3D object localisation using EIT measurements at two levels. Physiol. Meas. 17:189-199, 1993
    • (1993) Physiol. Meas. , vol.17 , pp. 189-199
    • Rabbani, K.S.1    Hassan, M.2    Kiber, A.3
  • 8
    • 0026254051 scopus 로고
    • Studies on the effect of the third dimension on a two dimensional electrical impedance tomography system
    • Rabbani K. S., H. Kabir. Studies on the effect of the third dimension on a two dimensional electrical impedance tomography system. Clin. Phys. Physiol. Meas. 12:393-402, 1991
    • (1991) Clin. Phys. Physiol. Meas. , vol.12 , pp. 393-402
    • Rabbani, K.S.1    Kabir, H.2
  • 12
    • 0030047395 scopus 로고    scopus 로고
    • Feasibility of neonatal lung imaging using electrical impedance tomography
    • Taktak A., A. Spencer, P. Record, R. Gadd, P. Rolfe. Feasibility of neonatal lung imaging using electrical impedance tomography. Early Hum. Dev. 44:131-138, 1996
    • (1996) Early Hum. Dev. , vol.44 , pp. 131-138
    • Taktak, A.1    Spencer, A.2    Record, P.3    Gadd, R.4    Rolfe, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.