메뉴 건너뛰기




Volumn 71, Issue 3-4, 2004, Pages 683-692

Detectors for medical radioisotope imaging: Demands and perspectives

Author keywords

Gamma camera; Medical imaging; PET; Radiation detectors; SPECT

Indexed keywords

LIVING ORGANISMS; RADIOISOTOPE IMAGING;

EID: 4344710504     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radphyschem.2004.04.058     Document Type: Conference Paper
Times cited : (6)

References (40)
  • 1
    • 36849139664 scopus 로고
    • Scintillation camera
    • Anger H.O. Scintillation camera. Rev. Sci. Instr. 29:1958;27-33
    • (1958) Rev. Sci. Instr. , vol.29 , pp. 27-33
    • Anger, H.O.1
  • 2
    • 4244180299 scopus 로고
    • Charge transport in arrays of semiconductor gamma-ray detectors
    • Barret H.H., Eskin J.D., Barber H.B. Charge transport in arrays of semiconductor gamma-ray detectors. Phys. Rev. Lett. 75(1):1995;156-159
    • (1995) Phys. Rev. Lett. , vol.75 , Issue.1 , pp. 156-159
    • Barret, H.H.1    Eskin, J.D.2    Barber, H.B.3
  • 5
    • 0033870513 scopus 로고    scopus 로고
    • A combined PET/CT scanner for clinical oncology
    • Beyer T., et al. A combined PET/CT scanner for clinical oncology. J. Nucl. Med. 41:2000;1369-1379
    • (2000) J. Nucl. Med. , vol.41 , pp. 1369-1379
    • Beyer, T.1
  • 7
    • 0030784192 scopus 로고    scopus 로고
    • A high pressure xenon self-triggered scintillation drift chamber with 3 D sensitivity in the range 20-140 keV deposited energy
    • Bolozdynya A., Egorov V., Koutchenkov A., et al. A high pressure xenon self-triggered scintillation drift chamber with 3 D sensitivity in the range 20-140. keV deposited energy Nucl. Instrum. Methods A. 385:1997;225-238
    • (1997) Nucl. Instrum. Methods a , vol.385 , pp. 225-238
    • Bolozdynya, A.1    Egorov, V.2    Koutchenkov, A.3
  • 8
    • 0001237415 scopus 로고    scopus 로고
    • Novel electrode design for single-carrier charge collection in semiconductor nuclear radiation detectors
    • Butler J.F. Novel electrode design for single-carrier charge collection in semiconductor nuclear radiation detectors. Nucl. Instrum. Methods A. 396:1997;427-430
    • (1997) Nucl. Instrum. Methods a , vol.396 , pp. 427-430
    • Butler, J.F.1
  • 9
    • 0032099857 scopus 로고    scopus 로고
    • CdZnTe solid-state gamma camera
    • Butler J.F., et al. CdZnTe solid-state gamma camera. IEEE Trans. Nucl. Sci. 45(3):1998;359-363
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.3 , pp. 359-363
    • Butler, J.F.1
  • 10
    • 84939045331 scopus 로고
    • A multicrystal two dimensional BGO detector system for positron emission tomography
    • Casey M.E., Nutt R. A multicrystal two dimensional BGO detector system for positron emission tomography. IEEE Trans. Nucl. Sci. 37:1986;460-463
    • (1986) IEEE Trans. Nucl. Sci. , vol.37 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2
  • 16
    • 0034450430 scopus 로고    scopus 로고
    • Gamma-ray imaging using a CdZnTe Pixel array and a high resolution parallel-hole collimator
    • Kastis G.A., et al. Gamma-ray imaging using a CdZnTe Pixel array and a high resolution parallel-hole collimator. IEEE Trans. Nucl. Sci. 47(6):2000;1923-1927
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.6 , pp. 1923-1927
    • Kastis, G.A.1
  • 17
    • 0030211551 scopus 로고    scopus 로고
    • Simultaneous SPECT and CT with an opposed dual head gamma camera system and conventional parallel hole collimators
    • Kimiaei S., Larsson S.A. Simultaneous SPECT and CT with an opposed dual head gamma camera system and conventional parallel hole collimators. IEEE Trans. Nucl. Sci. 43(4):1996;2239-2243
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.4 , pp. 2239-2243
    • Kimiaei, S.1    Larsson, S.A.2
  • 19
    • 3743051310 scopus 로고    scopus 로고
    • Radioisotopes in medicine
    • Lima J.J.P. Radioisotopes in medicine. Eur. J. Phys. 19:1998;485-497
    • (1998) Eur. J. Phys. , vol.19 , pp. 485-497
    • Lima, J.J.P.1
  • 21
    • 0032587211 scopus 로고    scopus 로고
    • 99mTc-MIBI scintimammography using a dedicated nuclear mammograph
    • 99mTc-MIBI scintimammography using a dedicated nuclear mammograph. J. Nucl. Med. 40(1):1999;46-51
    • (1999) J. Nucl. Med. , vol.40 , Issue.1 , pp. 46-51
    • Maini, C.L.1
  • 22
    • 0035250737 scopus 로고    scopus 로고
    • A new design for a high resolution, high efficiency CZT gamma camera detector
    • Mestais C., et al. A new design for a high resolution, high efficiency CZT gamma camera detector. Nucl. Instrum. Methods A. 458:2001;62-67
    • (2001) Nucl. Instrum. Methods a , vol.458 , pp. 62-67
    • Mestais, C.1
  • 25
    • 33747026167 scopus 로고
    • A xenon high-pressure proportional scintillation camera for X and γ-ray imaging
    • Nguen Ngoc H., Jeanjean J., Itoh H., Charpak G. A xenon high-pressure proportional scintillation camera for X and γ-ray imaging. Nucl. Instrum. Methods. 172:1980;603-608
    • (1980) Nucl. Instrum. Methods , vol.172 , pp. 603-608
    • Nguen Ngoc, H.1    Jeanjean, J.2    Itoh, H.3    Charpak, G.4
  • 26
    • 0030365381 scopus 로고    scopus 로고
    • First results from YAP:Ce gamma camera for small animal studies
    • Notaristefani F., et al. First results from YAP:Ce gamma camera for small animal studies. Trans. Nucl. Sci. 43(6):1996;3264-3270
    • (1996) Trans. Nucl. Sci. , vol.43 , Issue.6 , pp. 3264-3270
    • Notaristefani, F.1
  • 27
    • 0032318334 scopus 로고    scopus 로고
    • Dedicated gamma camera for single photon emission mammography (SPEM)
    • Pani R., et al. Dedicated gamma camera for single photon emission mammography (SPEM). Trans. Nucl. Sci. 45(6):1998;3127-3133
    • (1998) Trans. Nucl. Sci. , vol.45 , Issue.6 , pp. 3127-3133
    • Pani, R.1
  • 29
    • 0033887446 scopus 로고    scopus 로고
    • Image fusion using an integrated dual-head coincidence camera with X-ray tube based attenuation maps
    • Patton J.A., Delbeke D., Sandler M.P. Image fusion using an integrated dual-head coincidence camera with X-ray tube based attenuation maps. J. Nucl. Med. 41:2000;1364-1379
    • (2000) J. Nucl. Med. , vol.41 , pp. 1364-1379
    • Patton, J.A.1    Delbeke, D.2    Sandler, M.P.3
  • 30
    • 0035250743 scopus 로고    scopus 로고
    • Medical applications of CdTe and CdZnTe detectors
    • Scheiber C., Giakos G. Medical applications of CdTe and CdZnTe detectors. Nucl. Instrum. Methods A. 458:2001;12-25
    • (2001) Nucl. Instrum. Methods a , vol.458 , pp. 12-25
    • Scheiber, C.1    Giakos, G.2
  • 32
    • 0032685817 scopus 로고    scopus 로고
    • Optimum spectroscopic performance from CZT γ- And X-ray detectors with pad and strip segmentation
    • Shor A., Eisen Y., Mardor I. Optimum spectroscopic performance from CZT γ- and X-ray detectors with pad and strip segmentation. Nucl. Instrum. Methods A. 428:1999;182-192
    • (1999) Nucl. Instrum. Methods a , vol.428 , pp. 182-192
    • Shor, A.1    Eisen, Y.2    Mardor, I.3
  • 36
    • 0028493581 scopus 로고
    • Positioning and energy response of PET block detectors with different light sharing schemes
    • Tornai M.P., Germano T.M., Hoffmman E.J. Positioning and energy response of PET block detectors with different light sharing schemes. IEEE Trans. Nucl. Sci. 41(4):1994;1458
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , Issue.4 , pp. 1458
    • Tornai, M.P.1    Germano, T.M.2    Hoffmman, E.J.3
  • 37
    • 0035277432 scopus 로고    scopus 로고
    • Inorganic-scintillator development
    • Van Eijk C. Inorganic-scintillator development. Nucl. Instrum. Methods A. 460:2001;1-14
    • (2001) Nucl. Instrum. Methods a , vol.460 , pp. 1-14
    • Van Eijk, C.1
  • 38
    • 0035250949 scopus 로고    scopus 로고
    • Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    • Verger L., et al. Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications. Nucl. Instrum. Methods A. 458:2001;297-309
    • (2001) Nucl. Instrum. Methods a , vol.458 , pp. 297-309
    • Verger, L.1
  • 40
    • 0036464422 scopus 로고    scopus 로고
    • The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph
    • Wienhard K., et al. The ECAT HRRT. performance and first clinical application of the new high resolution research tomograph IEEE Trans. Nucl. Sci. 49(1):2002;104-110
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.1 , pp. 104-110
    • Wienhard, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.