Volumn 18, Issue 2, 2004, Pages 75-79

Performance of a digital PCO2/SpO2 ear sensor

Author keywords

Analog; Digital; Hyper hypocapnia; PCO2; Pulse oximetry

Indexed keywords

ALGORITHMS; CARBON DIOXIDE; MEDICAL IMAGING; OXIMETERS; PARTIAL PRESSURE; SENSORS; SIGNAL PROCESSING; VENTILATION;

EID: 4344704967     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1023/B:JOCM.0000032693.78829.42     Document Type: Article
Times cited : (36)

References (11)
  • 1
    • 0005445261 scopus 로고    scopus 로고
    • The current status of transcutaneous blood gas analysis and monitoring
    • Severinghaus JW. The current status of transcutaneous blood gas analysis and monitoring. Blood Gas News 1998; 7 (2): 4-9
    • (1998) Blood Gas News , vol.7 , Issue.2 , pp. 4-9
    • Severinghaus, J.W.1
  • 2
    • 0034072367 scopus 로고    scopus 로고
    • Pulse oximeters' reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximeters
    • Bohnhorst B, Peter CS, Poets, CF. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters. Crit Care Med 2000; 28: 1565-1568
    • (2000) Crit. Care Med. , vol.28 , pp. 1565-1568
    • Bohnhorst, B.1    Peter, C.S.2    Poets, C.F.3
  • 4
    • 0023549911 scopus 로고
    • Accuracy of response of six pulse oximeters to profound hypoxia
    • Severinghaus JW, Naifeh KH. Accuracy of response of six pulse oximeters to profound hypoxia. Anesthesiology 1987; 67 (4): 551-558
    • (1987) Anesthesiology , vol.67 , Issue.4 , pp. 551-558
    • Severinghaus, J.W.1    Naifeh, K.H.2
  • 6
    • 4344677341 scopus 로고    scopus 로고
    • Standard specification for alarm signals in medical equipment
    • American Society for Testing and Materials (ASTM) West Conshohocken, PA. ASTM
    • American Society for Testing and Materials (ASTM). Standard specification for alarm signals in medical equipment. West Conshohocken, PA. ASTM 1999; F1463-F1493
    • (1999)
  • 7
    • 4344699134 scopus 로고    scopus 로고
    • World's first combined digital pulse oximetry and carbon dioxide tension ear sensor
    • ISIAPO Meeting Abstract A6
    • Hayoz J, Rohling R, Tschupp A. World's first combined digital pulse oximetry and carbon dioxide tension ear sensor. ISIAPO 2001; Meeting Abstract A6
    • (2001)
    • Hayoz, J.1    Rohling, R.2    Tschupp, A.3
  • 9
    • 0032867708 scopus 로고    scopus 로고
    • Effect of peripheral perfusion on accuracy of pulse oximetry in children
    • Villanueva R, Bell C, Kain ZN, Colingo KA. Effect of peripheral perfusion on accuracy of pulse oximetry in children. J Clin Anesth 1999; 11 (4): 317-322
    • (1999) J. Clin. Anesth. , vol.11 , Issue.4 , pp. 317-322
    • Villanueva, R.1    Bell, C.2    Kain, Z.N.3    Colingo, K.A.4
  • 10
    • 0035954012 scopus 로고    scopus 로고
    • Nocturnal hypoxaemia and central-nervous-system events in sickle-cell disease
    • Kirkham FJ, Hewes DK, Prengler M, Wade A, Lane R, Evans JP. Nocturnal hypoxaemia and central-nervous-system events in sickle-cell disease. Lancet 2001; 357 (9269): 1656-1659
    • (2001) Lancet , vol.357 , Issue.9269 , pp. 1656-1659
    • Kirkham, F.J.1    Hewes, D.K.2    Prengler, M.3    Wade, A.4    Lane, R.5    Evans, J.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.