메뉴 건너뛰기




Volumn 22, Issue 5, 2004, Pages 1035-1043

Bioactive cement or ceramic/porous coating vs. conventional cement to obtain early stability of the acetabular cup. Randomised study of 96 hips followed with radiostereometry

Author keywords

Bone cement; Fixation; Fluoride; Osteoporosis; Porous coated; RSA; THR

Indexed keywords

BONE CEMENT; FLUORIDE; GENTAMICIN BONE CEMENT; PALACOS;

EID: 4344687196     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.orthres.2003.09.012     Document Type: Article
Times cited : (14)

References (39)
  • 1
    • 0028275977 scopus 로고
    • Periarticular bone in rheumatoid arthritis versus arthrosis. Histomorphometry in 103 hip biopsies
    • Akesson K. Onsten I. Obrant K.J. Periarticular bone in rheumatoid arthritis versus arthrosis. Histomorphometry in 103 hip biopsies Acta. Orthop. Scand. 65 1994 135-138
    • (1994) Acta. Orthop. Scand. , vol.65 , pp. 135-138
    • Akesson, K.1    Onsten, I.2    Obrant, K.J.3
  • 2
    • 0026527960 scopus 로고
    • Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review
    • Barrack R.L. Mulroy R.D.Jr. Harris W.H. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review J. Bone Jnt. Surg. Br. 74B 1992 385-389
    • (1992) J. Bone Jnt. Surg. Br. , vol.74 B , pp. 385-389
    • Barrack, R.L.1    Mulroy Jr., R.D.2    Harris, W.H.3
  • 4
    • 0022646071 scopus 로고
    • Socket loosening after hip arthroplasty. Radiographic observations in 241 cases up to 15 years
    • Carlsson A.S. Gentz C.F. Sanzen L. Socket loosening after hip arthroplasty. Radiographic observations in 241 cases up to 15 years Acta. Orthop. Scand. 57 1986 97-100
    • (1986) Acta. Orthop. Scand. , vol.57 , pp. 97-100
    • Carlsson, A.S.1    Gentz, C.F.2    Sanzen, L.3
  • 5
    • 0034880594 scopus 로고    scopus 로고
    • The Harris-Galante total hip arthroplasty: A minimum 8-year follow-up study
    • Cruz-Pardos A. Garcia-Cimbrelo E. The Harris-Galante total hip arthroplasty: a minimum 8-year follow-up study J. Arthroplasty 16 2001 586-597
    • (2001) J. Arthroplasty , vol.16 , pp. 586-597
    • Cruz-Pardos, A.1    Garcia-Cimbrelo, E.2
  • 6
    • 0344629811 scopus 로고    scopus 로고
    • Highly cross-linked polyethylene in cemented THA: Randomized study of 61 hips
    • Digas G. Karrholm J. Thanner J. Malchau H. Herberts P. Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips Clin. Orthop. 417 2003 126-138
    • (2003) Clin. Orthop. , vol.417 , pp. 126-138
    • Digas, G.1    Karrholm, J.2    Thanner, J.3    Malchau, H.4    Herberts, P.5
  • 7
    • 33644499782 scopus 로고    scopus 로고
    • Fluoride containing acrylic bone cement in total hip arthroplasty. Randomisedevaluation of 97 stems using radiostereometry and DEXA
    • In press
    • Digas G, Thanner J, Anderberg C, Kärrholm J. Fluoride containing acrylic bone cement in total hip arthroplasty. Randomisedevaluation of 97 stems using radiostereometry and DEXA. J Arthroplasty, in press
    • J. Arthroplasty
    • Digas, G.1    Thanner, J.2    Anderberg, C.3    Kärrholm, J.4
  • 8
    • 0142147210 scopus 로고    scopus 로고
    • Increase in early polyethylene wear after sterilization with ethylene oxide: Radiostereometric analyses of 201 total hips
    • Digas G. Thanner J. Nivbrant B. Rohrl S. Strom H. Karrholm J. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips Acta. Orthop. Scand. 74 2003 531-541
    • (2003) Acta. Orthop. Scand. , vol.74 , pp. 531-541
    • Digas, G.1    Thanner, J.2    Nivbrant, B.3    Rohrl, S.4    Strom, H.5    Karrholm, J.6
  • 9
    • 0018186475 scopus 로고
    • The radiation improvement of polyethylene prostheses. A preliminary study
    • Grobbelaar C.J. du Plessis T.A. Marais F. The radiation improvement of polyethylene prostheses. A preliminary study J. Bone Jnt. Surg. Br. 60B 1978 370-374
    • (1978) J. Bone Jnt. Surg. Br. , vol.60 B , pp. 370-374
    • Grobbelaar, C.J.1    du Plessis, T.A.2    Marais, F.3
  • 10
    • 0348049448 scopus 로고    scopus 로고
    • Radiographic evaluation of Charnley cups used in first-time revision: Repeated observations for 7-15 years
    • Hultmark P. Hostner J. Herberts P. Karrholm J. Radiographic evaluation of Charnley cups used in first-time revision: repeated observations for 7-15 years J. Arthroplasty 18 2003 1005-1015
    • (2003) J. Arthroplasty , vol.18 , pp. 1005-1015
    • Hultmark, P.1    Hostner, J.2    Herberts, P.3    Karrholm, J.4
  • 12
    • 0026497889 scopus 로고
    • Migration of porous coated acetabular prostheses fixed with screws: Roentgen stereophotogrammetric analysis
    • Karrholm J. Snorrason F. Migration of porous coated acetabular prostheses fixed with screws: Roentgen stereophotogrammetric analysis J. Orthop. Res. 10 1992 826-835
    • (1992) J. Orthop. Res. , vol.10 , pp. 826-835
    • Karrholm, J.1    Snorrason, F.2
  • 14
    • 0033798709 scopus 로고    scopus 로고
    • Radiopacity and fatigue characterization of a novel acrylic bone cement with sodium fluoride
    • Minari C. Cristofolini L. Baruffaldi F. Pierotti L. Radiopacity and fatigue characterization of a novel acrylic bone cement with sodium fluoride Artif. Organs. 24 2000 751-757
    • (2000) Artif. Organs. , vol.24 , pp. 751-757
    • Minari, C.1    Cristofolini, L.2    Baruffaldi, F.3    Pierotti, L.4
  • 15
    • 0028243001 scopus 로고
    • Theories of wear and loosening in hip prostheses. Wear-induced loosening vs loosening-induced wear - A review
    • Mjoberg B. Theories of wear and loosening in hip prostheses. Wear-induced loosening vs loosening-induced wear--a review Acta. Orthop. Scand. 65 1994 361-371
    • (1994) Acta. Orthop. Scand. , vol.65 , pp. 361-371
    • Mjoberg, B.1
  • 16
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties
    • Recipient of the 1999 HAP Paul Award
    • Muratoglu O.K. Bragdon C.R. O'Connor D.O. Jasty M. Harris W.H. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award J. Arthroplasty 16 2001 149-160
    • (2001) J. Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 17
    • 0035664852 scopus 로고    scopus 로고
    • Bone cement with reduced proportion of monomer in total hip arthroplasty: Preclinical evaluation and randomized study of 47 cases with 5 years' follow-up
    • Nivbrant B. Karrholm J. Rohrl S. Hassander H. Wesslen B. Bone cement with reduced proportion of monomer in total hip arthroplasty: preclinical evaluation and randomized study of 47 cases with 5 years' follow-up Acta. Orthop. Scand. 72 2001 572-584
    • (2001) Acta. Orthop. Scand. , vol.72 , pp. 572-584
    • Nivbrant, B.1    Karrholm, J.2    Rohrl, S.3    Hassander, H.4    Wesslen, B.5
  • 18
    • 0033372584 scopus 로고    scopus 로고
    • Increased migration of the SHP prosthesis: Radiostereometric comparison with the Lubinus SP2 design in 40 cases
    • Nivbrant B. Karrholm J. Soderlund P. Increased migration of the SHP prosthesis: radiostereometric comparison with the Lubinus SP2 design in 40 cases Acta. Orthop. Scand. 70 1999 569-577
    • (1999) Acta. Orthop. Scand. , vol.70 , pp. 569-577
    • Nivbrant, B.1    Karrholm, J.2    Soderlund, P.3
  • 19
    • 0036714484 scopus 로고    scopus 로고
    • Charnley low-friction arthroplasty: A worldwide retrospective review at 15 to 20 years
    • Older J. Charnley low-friction arthroplasty: a worldwide retrospective review at 15 to 20 years J. Arthroplasty 17 2002 675-680
    • (2002) J. Arthroplasty , vol.17 , pp. 675-680
    • Older, J.1
  • 20
    • 0028966191 scopus 로고
    • Micromotion of the acetabular component and periacetabular bone morphology
    • Onsten I. Akesson K. Obrant K.J. Micromotion of the acetabular component and periacetabular bone morphology Clin. Orthop. 310 1995 103-110
    • (1995) Clin. Orthop. , vol.310 , pp. 103-110
    • Onsten, I.1    Akesson, K.2    Obrant, K.J.3
  • 21
    • 0027170489 scopus 로고
    • Socket migration after Charnley arthroplasty in rheumatoid arthritis and osteoarthritis. A Roentgen stereophotogrammetric study
    • Onsten I. Bengner U. Besjakov J. Socket migration after Charnley arthroplasty in rheumatoid arthritis and osteoarthritis. A Roentgen stereophotogrammetric study J. Bone Jnt. Surg. Br. 75B 1993 677-680
    • (1993) J. Bone Jnt. Surg. Br. , vol.75 B , pp. 677-680
    • Onsten, I.1    Bengner, U.2    Besjakov, J.3
  • 22
    • 0028157703 scopus 로고
    • Improved radiographic survival of the Charnley prosthesis in rheumatoid arthritis and osteoarthritis. Results of new versus old operative techniques in 402 hips
    • Onsten I. Besjakov J. Carlsson A.S. Improved radiographic survival of the Charnley prosthesis in rheumatoid arthritis and osteoarthritis. Results of new versus old operative techniques in 402 hips J. Arthroplasty 9 1994 3-8
    • (1994) J. Arthroplasty , vol.9 , pp. 3-8
    • Onsten, I.1    Besjakov, J.2    Carlsson, A.S.3
  • 23
    • 0028587802 scopus 로고
    • Cemented versus uncemented socket in hip arthroplasty. A radiostereometric study of 60 randomized hips followed for 2 years
    • Onsten I. Carlsson A.S. Cemented versus uncemented socket in hip arthroplasty. A radiostereometric study of 60 randomized hips followed for 2 years Acta. Orthop. Scand. 65 1994 517-521
    • (1994) Acta. Orthop. Scand. , vol.65 , pp. 517-521
    • Onsten, I.1    Carlsson, A.S.2
  • 24
    • 0028329997 scopus 로고
    • Migration of acetabular components, inserted with and without cement, in one-stage bilateral hip arthroplasty. A controlled, randomized study using Roentgen stereophotogrammetric analysis
    • Onsten I. Carlsson A.S. Ohlin A. Nilsson J.A. Migration of acetabular components, inserted with and without cement, in one-stage bilateral hip arthroplasty. A controlled, randomized study using Roentgen stereophotogrammetric analysis J. Bone Jnt. Surg. Am. 76A 1994 185-194
    • (1994) J. Bone Jnt. Surg. Am. , vol.76 A , pp. 185-194
    • Onsten, I.1    Carlsson, A.S.2    Ohlin, A.3    Nilsson, J.A.4
  • 25
    • 0033922311 scopus 로고    scopus 로고
    • Wear of high-dose gamma-irradiated polyethylene in total hip replacements
    • Oonishi H. Kadoya Y. Wear of high-dose gamma-irradiated polyethylene in total hip replacements J. Orthop. Sci. 5 2000 223-228
    • (2000) J. Orthop. Sci. , vol.5 , pp. 223-228
    • Oonishi, H.1    Kadoya, Y.2
  • 28
    • 0018940066 scopus 로고
    • Total hip arthroplasty in protrusio acetabuli of rheumatoid arthritis
    • Ranawat C.S. Dorr L.D. Inglis A.E. Total hip arthroplasty in protrusio acetabuli of rheumatoid arthritis J. Bone Jnt. Surg. Am. 62A 1980 1059-1065
    • (1980) J. Bone Jnt. Surg. Am. , vol.62 A , pp. 1059-1065
    • Ranawat, C.S.1    Dorr, L.D.2    Inglis, A.E.3
  • 29
    • 0025675531 scopus 로고
    • Total hip arthroplasty with cement. A long-term radiographic analysis in patients who are older than fifty and younger than fifty years
    • Sarmiento A. Ebramzadeh E. Gogan W.J. McKellop H.A. Total hip arthroplasty with cement. A long-term radiographic analysis in patients who are older than fifty and younger than fifty years J. Bone Jnt. Surg. Am. 72A 1990 1470-1476
    • (1990) J. Bone Jnt. Surg. Am. , vol.72 A , pp. 1470-1476
    • Sarmiento, A.1    Ebramzadeh, E.2    Gogan, W.J.3    McKellop, H.A.4
  • 30
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system Acta. Orthop. Scand. Suppl. 232 1989 1-51
    • (1989) Acta. Orthop. Scand. Suppl. , vol.232 , pp. 1-51
    • Selvik, G.1
  • 31
    • 0027156993 scopus 로고
    • Fixation of cemented acetabular prostheses. The influence of preoperative diagnosis
    • Snorrason F. Karrholm J. Holmgren C. Fixation of cemented acetabular prostheses. The influence of preoperative diagnosis J. Arthroplasty 8 1993 83-90
    • (1993) J. Arthroplasty , vol.8 , pp. 83-90
    • Snorrason, F.1    Karrholm, J.2    Holmgren, C.3
  • 32
    • 0027897660 scopus 로고
    • Determining the movements of the skeleton using well-configured markers
    • Soderkvist I. Wedin P.A. Determining the movements of the skeleton using well-configured markers J. Biomech. 26 1993 1473-1477
    • (1993) J. Biomech. , vol.26 , pp. 1473-1477
    • Soderkvist, I.1    Wedin, P.A.2
  • 33
    • 0036829582 scopus 로고    scopus 로고
    • Does sodium fluoride in bone cement affect implant fixation - Part II: Evaluation of the effect of sodium fluoride additions to acrylic bone cement and the fixation of titanium implants in ovariectomized rabbits
    • Sundfeldt M. Persson J. Swanpalmer J. Wennerberg A. Karrholm J. Johansson C.B. et al. Does sodium fluoride in bone cement affect implant fixation--Part II: Evaluation of the effect of sodium fluoride additions to acrylic bone cement and the fixation of titanium implants in ovariectomized rabbits J. Mater. Sci. Mater. Med. 13 2002 1045-1050
    • (2002) J. Mater. Sci. Mater. Med. , vol.13 , pp. 1045-1050
    • Sundfeldt, M.1    Persson, J.2    Swanpalmer, J.3    Wennerberg, A.4    Karrholm, J.5    Johansson, C.B.6
  • 34
    • 0028989434 scopus 로고
    • Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties
    • Thanner J. Freij-Larsson C. Karrholm J. Malchau H. Wesslen B. Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties Acta. Orthop. Scand. 66 1995 207-214
    • (1995) Acta. Orthop. Scand. , vol.66 , pp. 207-214
    • Thanner, J.1    Freij-Larsson, C.2    Karrholm, J.3    Malchau, H.4    Wesslen, B.5
  • 35
    • 0034047218 scopus 로고    scopus 로고
    • Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: A randomized study of 64 hips
    • Thanner J. Karrholm J. Herberts P. Malchau H. Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips J. Arthroplasty 15 2000 405-412
    • (2000) J. Arthroplasty , vol.15 , pp. 405-412
    • Thanner, J.1    Karrholm, J.2    Herberts, P.3    Malchau, H.4
  • 36
    • 0032908207 scopus 로고    scopus 로고
    • Porous cups with and without hydroxyapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry
    • Thanner J. Karrholm J. Herberts P. Malchau H. Porous cups with and without hydroxyapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry J. Arthroplasty 14 1999 266-271
    • (1999) J. Arthroplasty , vol.14 , pp. 266-271
    • Thanner, J.1    Karrholm, J.2    Herberts, P.3    Malchau, H.4
  • 37
    • 0030483297 scopus 로고    scopus 로고
    • Migration of press-fit cups fixed with poly-l-lactic acid or titanium screws: A randomized study using radiostereometry
    • Thanner J. Karrholm J. Malchau H. Wallinder L. Herberts P. Migration of press-fit cups fixed with poly-l-lactic acid or titanium screws: a randomized study using radiostereometry J. Orthop. Res. 14 1996 895-900
    • (1996) J. Orthop. Res. , vol.14 , pp. 895-900
    • Thanner, J.1    Karrholm, J.2    Malchau, H.3    Wallinder, L.4    Herberts, P.5
  • 39
    • 0032922181 scopus 로고    scopus 로고
    • Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report
    • Wroblewski B.M. Siney P.D. Fleming P.A. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report J. Bone Jnt. Surg. Br. 81 1999 54-55
    • (1999) J. Bone Jnt. Surg. Br. , vol.81 , pp. 54-55
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.