메뉴 건너뛰기




Volumn 20, Issue 3, 2004, Pages 531-537

New FOCI pulses with reduced radiofrequency power requirements

Author keywords

Adiabaticity; RF power deposition; RF pulse; Spin echo imaging

Indexed keywords

ARTICLE; CALCULATION; EXCITATION; FREQUENCY OFFSET CORRECTED INVERSION PULSE; IMAGING SYSTEM; IN VIVO STUDY; MATHEMATICAL ANALYSIS; POWER SPECTRUM; PRIORITY JOURNAL; RADIATION ABSORPTION; RADIATION PHYSICS; RADIOFREQUENCY; VARIABLE RATE SELECTIVE EXCITATION;

EID: 4344685477     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20134     Document Type: Article
Times cited : (18)

References (15)
  • 2
    • 4243461379 scopus 로고
    • Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equations
    • Silver MS, Joseph RI, Hoult DI. Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equations. Phys Rev A 1985;31:2753-2755.
    • (1985) Phys Rev A , vol.31 , pp. 2753-2755
    • Silver, M.S.1    Joseph, R.I.2    Hoult, D.I.3
  • 3
    • 0030716493 scopus 로고    scopus 로고
    • Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system
    • Payne GS, Leach MO. Implementation and evaluation of frequency offset corrected inversion (FOCI) pulses on a clinical MR system. Magn Reson Med 1997;38:828-833.
    • (1997) Magn Reson Med , vol.38 , pp. 828-833
    • Payne, G.S.1    Leach, M.O.2
  • 4
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995:34:293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 6
    • 0032749944 scopus 로고    scopus 로고
    • Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: Comparison with hyperbolic secant
    • Yongbi MN, Yang Y, Frank JA, Duyn JH. Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant. Magn Reson Med 1999:42:1098-1105.
    • (1999) Magn Reson Med , vol.42 , pp. 1098-1105
    • Yongbi, M.N.1    Yang, Y.2    Frank, J.A.3    Duyn, J.H.4
  • 7
  • 9
    • 0030207289 scopus 로고    scopus 로고
    • Use of amplitude and frequency transformations to generate adiabatic pulses of wide bandwidth and low RF power deposition
    • Shen J. Use of amplitude and frequency transformations to generate adiabatic pulses of wide bandwidth and low RF power deposition. J Magn Reson B 1996;112:131-140.
    • (1996) J Magn Reson B , vol.112 , pp. 131-140
    • Shen, J.1
  • 10
    • 0030634087 scopus 로고    scopus 로고
    • Adiabatic slice-selective excitation for surface coils
    • Shen J, Rothman DL. Adiabatic slice-selective excitation for surface coils, J Magn Reson 1997;24:72-79.
    • (1997) J Magn Reson , vol.24 , pp. 72-79
    • Shen, J.1    Rothman, D.L.2
  • 13
    • 0024493728 scopus 로고
    • Localized high-resolution proton NMR spectroscopy using stimulated echoes: Initial applications to human brain in vivo
    • Frahm J, Bruhn H, Gyngell ML, Merboldt KD, Hanicke W, Sauter R. Localized high-resolution proton NMR spectroscopy using stimulated echoes: initial applications to human brain in vivo. Magn Reson Med 1989:9:79-93.
    • (1989) Magn Reson Med , vol.9 , pp. 79-93
    • Frahm, J.1    Bruhn, H.2    Gyngell, M.L.3    Merboldt, K.D.4    Hanicke, W.5    Sauter, R.6
  • 14
    • 0026116321 scopus 로고
    • Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm
    • Pauly J, Le Roux P, Nishimura D, Macovski A. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm. IEEE Trans Med Imaging 1991;10:53-65.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 53-65
    • Pauly, J.1    Le Roux, P.2    Nishimura, D.3    Macovski, A.4
  • 15
    • 0002290966 scopus 로고
    • Experimental study of the optimal selective 180 degree radiofrequency pulses
    • Mao J, Mareci TH, Andrew ER. Experimental study of the optimal selective 180 degree radiofrequency pulses. J Magn Reson 1988;79:1-10.
    • (1988) J Magn Reson , vol.79 , pp. 1-10
    • Mao, J.1    Mareci, T.H.2    Andrew, E.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.