메뉴 건너뛰기




Volumn 71, Issue 6, 2008, Pages 792-798

Methods to reduce patients' maximum skin dose during percutaneous coronary intervention for chronic total occlusion

Author keywords

Angioplasty; Catheterization; Coronary intervention; Dosage; Radiation

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION COEFFICIENT; FEMALE; FLUOROSCOPY; HUMAN; MALE; PERCUTANEOUS CORONARY INTERVENTION; PERIPHERAL OCCLUSIVE ARTERY DISEASE; RADIATION DOSE; RADIATION HAZARD; RISK REDUCTION; SKIN INJURY; SKIN TOXICITY; STATISTICAL SIGNIFICANCE; TIME; X RAY;

EID: 43249108566     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.21481     Document Type: Article
Times cited : (18)

References (21)
  • 1
    • 46849103267 scopus 로고
    • Avoidance of Serious X-Ray Induced Skin Injuries to Patients During Fluoroscopically-Guided Procedures
    • Food and Drug Administration, 9 September, Rockville, MD: Food and Drug Administration;
    • Food and Drug Administration. Avoidance of Serious X-Ray Induced Skin Injuries to Patients During Fluoroscopically-Guided Procedures. Statement 9 September 1994. Rockville, MD: Food and Drug Administration; 1994.
    • (1994) Statement
  • 2
    • 46849112089 scopus 로고
    • Recording Information in the Patient's Medical Record That Identifies the Potential for Serious X-Ray-Induced Skin Injuries Following Fluoroscopic Guided Procedures
    • Food and Drug Administration, 15 September, Rockville, MD: Food and Drug Administration;
    • Food and Drug Administration. Recording Information in the Patient's Medical Record That Identifies the Potential for Serious X-Ray-Induced Skin Injuries Following Fluoroscopic Guided Procedures. Statement 15 September 1995. Rockville, MD: Food and Drug Administration; 1995.
    • (1995) Statement
  • 3
    • 0028185452 scopus 로고
    • Potential biological effects following high X-ray dose interventional procedures
    • Wagner LK, Eifel PJ, Geise RA. Potential biological effects following high X-ray dose interventional procedures. J Vasc Interv Radiol 1994;5:71-84.
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 71-84
    • Wagner, L.K.1    Eifel, P.J.2    Geise, R.A.3
  • 4
    • 9644283113 scopus 로고    scopus 로고
    • Hirshfeld JW Jr, Balter S, Brinker JA, Kern MJ, Klein LW, Lindsay BD, Tommaso CL, Tracy CM, Wagner LK, Creager MA, Elnicki M, Hirshfeld JW Jr, Lorell BH, Rodgers GP, Tracy CM, Weitz HH; American College of Cardiology Foundation; American Heart Association; American College of Physicians. ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures. A report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training. J Am Coll Cardiol 2004;44:2259-2282.
    • Hirshfeld JW Jr, Balter S, Brinker JA, Kern MJ, Klein LW, Lindsay BD, Tommaso CL, Tracy CM, Wagner LK, Creager MA, Elnicki M, Hirshfeld JW Jr, Lorell BH, Rodgers GP, Tracy CM, Weitz HH; American College of Cardiology Foundation; American Heart Association; American College of Physicians. ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures. A report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training. J Am Coll Cardiol 2004;44:2259-2282.
  • 5
    • 29644447277 scopus 로고    scopus 로고
    • Radiation exposure to patient's skin during percutaneous coronary intervention for various lesions, including chronic total occlusion
    • Suzuki S, Furui S, Kohtake H, Yokoyama N, Kozuma K, Yamamoto Y, Isshiki T. Radiation exposure to patient's skin during percutaneous coronary intervention for various lesions, including chronic total occlusion. Circ J 2006;70:44-48.
    • (2006) Circ J , vol.70 , pp. 44-48
    • Suzuki, S.1    Furui, S.2    Kohtake, H.3    Yokoyama, N.4    Kozuma, K.5    Yamamoto, Y.6    Isshiki, T.7
  • 6
    • 33846580645 scopus 로고    scopus 로고
    • Factors affecting the patient's skin dose during percutaneous coronary intervention for chronic total occlusion
    • Suzuki S, Furui S, Isshiki T, Kozuma K, Endo G, Yamamoto Y, Yokoyama N. Factors affecting the patient's skin dose during percutaneous coronary intervention for chronic total occlusion. Circ J 2007;71:229-233.
    • (2007) Circ J , vol.71 , pp. 229-233
    • Suzuki, S.1    Furui, S.2    Isshiki, T.3    Kozuma, K.4    Endo, G.5    Yamamoto, Y.6    Yokoyama, N.7
  • 8
    • 33645800787 scopus 로고    scopus 로고
    • Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures
    • Chida K, Saito H, Otani H, Kohzuki M, Takahashi S, Yamada S, Shirato K, Zuguchi M. Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. Am J Roentgenol 2006;186:774-778.
    • (2006) Am J Roentgenol , vol.186 , pp. 774-778
    • Chida, K.1    Saito, H.2    Otani, H.3    Kohzuki, M.4    Takahashi, S.5    Yamada, S.6    Shirato, K.7    Zuguchi, M.8
  • 9
    • 0030868194 scopus 로고    scopus 로고
    • Radiation exposure to patients undergoing diagnostic and interventional cardiac catheterization procedures
    • Bakalyar DM, Castellani MD, Safian RD. Radiation exposure to patients undergoing diagnostic and interventional cardiac catheterization procedures. Cathet Cardiovasc Diagn 1997;42:121-125.
    • (1997) Cathet Cardiovasc Diagn , vol.42 , pp. 121-125
    • Bakalyar, D.M.1    Castellani, M.D.2    Safian, R.D.3
  • 10
    • 0030983107 scopus 로고    scopus 로고
    • Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty
    • Zorzetto M, Bernardi G, Morocutti G, Fontanelli A. Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty. Cathet Cardiovasc Diagn 1997; 40:48-51.
    • (1997) Cathet Cardiovasc Diagn , vol.40 , pp. 48-51
    • Zorzetto, M.1    Bernardi, G.2    Morocutti, G.3    Fontanelli, A.4
  • 13
    • 0029884484 scopus 로고    scopus 로고
    • Effective doses for coronary angiography
    • Leung KC, Martin CJ. Effective doses for coronary angiography. Br J Radiol 1996;69:426-431.
    • (1996) Br J Radiol , vol.69 , pp. 426-431
    • Leung, K.C.1    Martin, C.J.2
  • 14
    • 0003179172 scopus 로고
    • Recommendations of the International Commission on Radiological Protection. ICRP Publication 60
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann ICRP 1990;21:11-25.
    • (1990) Ann ICRP , vol.21 , pp. 11-25
  • 15
    • 29644447855 scopus 로고    scopus 로고
    • Avoidance of radiation injuries from Medical Interventional Procedures. ICRP Publication 85
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. Avoidance of radiation injuries from Medical Interventional Procedures. ICRP Publication 85. Ann ICRP 2000;30:25-43.
    • (2000) Ann ICRP , vol.30 , pp. 25-43
  • 17
    • 0042573918 scopus 로고    scopus 로고
    • Scientific Research Group, Japanese Society of Radiological Technology. [Research on the measurement of patient dose and protection in IVR]. [Article in Japanese]
    • Mizutani H; Scientific Research Group, Japanese Society of Radiological Technology. [Research on the measurement of patient dose and protection in IVR]. [Article in Japanese]. Nippon Hoshasen Gijutsu Gakkai Zasshi 2003;59:369-381.
    • (2003) Nippon Hoshasen Gijutsu Gakkai Zasshi , vol.59 , pp. 369-381
    • Mizutani, H.1
  • 20
    • 0034146244 scopus 로고    scopus 로고
    • Patient radiation exposure during coronary angiography and intervention
    • Fransson SG, Persliden J. Patient radiation exposure during coronary angiography and intervention. Acta Radiol 2000;41:142-144.
    • (2000) Acta Radiol , vol.41 , pp. 142-144
    • Fransson, S.G.1    Persliden, J.2
  • 21
    • 4544350201 scopus 로고    scopus 로고
    • Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access
    • Geijer H, Persliden J. Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access. Eur Radiol 2004;14:1674-1680.
    • (2004) Eur Radiol , vol.14 , pp. 1674-1680
    • Geijer, H.1    Persliden, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.