1
-
-
0024122491
-
The ability of diagnostic tests to estimate the remaining life of stator insulation
-
Stone G C, Sedding H G, Lloyd B A, et al. The ability of diagnostic tests to estimate the remaining life of stator insulation [J]. IEEE Trans. Energy Conversion, 1988, 3 (4): 833-840.
-
(1988)
IEEE Trans. Energy Conversion
, vol.3
, Issue.4
, pp. 833-840
-
-
Stone, G.C.1
Sedding, H.G.2
Lloyd, B.A.3
-
2
-
-
0026914386
-
Assessment of insulation condition in rotating machine stators
-
Gupta B K, Culbert I M. Assessment of insulation condition in rotating machine stators [J]. IEEE Trans. Energy Conversion, 1992, 7 (3): 500-508.
-
(1992)
IEEE Trans. Energy Conversion
, vol.7
, Issue.3
, pp. 500-508
-
-
Gupta, B.K.1
Culbert, I.M.2
-
3
-
-
0027594202
-
Progress of insulation aging and diagnostics of HV rotating machine windings in Japan
-
Kimura K. Progress of insulation aging and diagnostics of HV rotating machine windings in Japan [J]. IEEE Electrical Insulation Magazine, 1993, 9: 13-20.
-
(1993)
IEEE Electrical Insulation Magazine
, vol.9
, pp. 13-20
-
-
Kimura, K.1
-
4
-
-
0029528055
-
Analysis of inservice aged stator bars
-
Morin R, Novak J P, Bartnikas R, et al. Analysis of inservice aged stator bars [J]. IEEE Trans. Energy Conversion, 1995, 10 (4): 645-652.
-
(1995)
IEEE Trans. Energy Conversion
, vol.10
, Issue.4
, pp. 645-652
-
-
Morin, R.1
Novak, J.P.2
Bartnikas, R.3
-
5
-
-
0025469714
-
Pulse-count distribution as a possible diagnostic tool for assessing the level of degradation of rotating machine insulation
-
Geetha H N, Srinivas M B, Ramu T S. Pulse-count distribution as a possible diagnostic tool for assessing the level of degradation of rotating machine insulation [J]. IEEE Trans. Electr. Insul., 1990, 25 (4): 747-756.
-
(1990)
IEEE Trans. Electr. Insul.
, vol.25
, Issue.4
, pp. 747-756
-
-
Geetha, H.N.1
Srinivas, M.B.2
Ramu, T.S.3
-
6
-
-
0141905032
-
Diagnosis of stator winding insulation of large generator
-
Invited Paper, Nagoya, Japan, June 1-5
-
Xie H K, Yue B, Hao Y P. Diagnosis of stator winding insulation of large generator [C]. Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials, Invited Paper, Nagoya, Japan, June 1-5, 2003: 274-277.
-
(2003)
Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials
, pp. 274-277
-
-
Xie, H.K.1
Yue, B.2
Hao, Y.P.3
-
7
-
-
0028748501
-
An acoustic diagnostic technique for use with electric machine Insulation
-
Lee Y-S, Nelson J K, Scarton H A, et al. An acoustic diagnostic technique for use with electric machine Insulation [J]. IEEE Trans. Dielectr. Electr. Insul., 1994, 1 (6): 1186-1193.
-
(1994)
IEEE Trans. Dielectr. Electr. Insul.
, vol.1
, Issue.6
, pp. 1186-1193
-
-
Lee, Y.-S.1
Nelson, J.K.2
Scarton, H.A.3
-
8
-
-
0041661033
-
Assessment of insulation condition of generator stator bars based on velocity of ultrasonic waves
-
Hao Y P, Xie H K, Wang G L, et al. Assessment of insulation condition of generator stator bars based on velocity of ultrasonic waves [J]. IEEE Trans. Dielectr. Electr. Insul., 2003, 10 (3): 539-547.
-
(2003)
IEEE Trans. Dielectr. Electr. Insul.
, vol.10
, Issue.3
, pp. 539-547
-
-
Hao, Y.P.1
Xie, H.K.2
Wang, G.L.3
-
9
-
-
0036824961
-
Study on the application of ultrasonic technique to stator insulation diagnosis
-
Hao Y P, Yan B, Chen X L, et al. Study on the application of ultrasonic technique to stator insulation diagnosis [J]. Transactions of China Electrotechnical Society, 2002, 17 (5): 65-70.
-
(2002)
Transactions of China Electrotechnical Society
, vol.17
, Issue.5
, pp. 65-70
-
-
Hao, Y.P.1
Yan, B.2
Chen, X.L.3
-
10
-
-
0031383250
-
Thermal aging properties of mica/epoxy stator winding insulations
-
Minneapolis, Oct. 19-22
-
Kim H D, Kim T W, Kim J H, et al. Thermal aging properties of mica/epoxy stator winding insulations [C]. IEEE Annual Report-Conference on Electrical Insulation and Dielectric Phenomena, Minneapolis, Oct. 19-22, 1997: 419-422.
-
(1997)
IEEE Annual Report-Conference on Electrical Insulation and Dielectric Phenomena
, pp. 419-422
-
-
Kim, H.D.1
Kim, T.W.2
Kim, J.H.3
-
11
-
-
33646400856
-
The degradation assessment of epoxy/mica insulation under multi-stresses aging
-
Jia Z D, Hao Y P, Xie H K. The degradation assessment of epoxy/mica insulation under multi-stresses aging [J]. IEEE Trans. on Dielectrics and Electrical Insulation, 2006, 13 (2): 415-422.
-
(2006)
IEEE Trans. on Dielectrics and Electrical Insulation
, vol.13
, Issue.2
, pp. 45-422
-
-
Jia, Z.D.1
Hao, Y.P.2
Xie, H.K.3
-
12
-
-
0033733926
-
Degradation and breakdown of mica under partial discharge stressing
-
Shields A J, Kemp I J. Degradation and breakdown of mica under partial discharge stressing [J]. IEE Proc.-Sci. Meas. Technol., 2000, 147 (3): 105-109.
-
(2000)
IEE Proc.-Sci. Meas. Technol.
, vol.147
, Issue.3
, pp. 105-109
-
-
Shields, A.J.1
Kemp, I.J.2
-
13
-
-
0033732447
-
Degradation of epoxy resin by partial discharges
-
Hepburn D M, Kemp I J, Shields A J, et al. Degradation of epoxy resin by partial discharges [J]. IEE Proc.-Sci. Meas. Technol., 2000, 147 (3): 97-104.
-
(2000)
IEE Proc.-Sci. Meas. Technol.
, vol.147
, Issue.3
, pp. 97-104
-
-
Hepburn, D.M.1
Kemp, I.J.2
Shields, A.J.3
-
14
-
-
43249109044
-
-
Chinese source
-
-
-
-
15
-
-
43249101322
-
-
Chinese source
-
-
-
-
16
-
-
43249084408
-
Research on the occurrence of Fe in sericite, Chuzhou, Anhui Province, Shotheast China
-
Zhao Ren, Yin Lin, Zhao Lianze, et al. Research on the occurrence of Fe in sericite, Chuzhou, Anhui Province, Shotheast China [J]. Mineral Transaction, 2004, 24 (3): 319-314.
-
(2004)
Mineral Transaction
, vol.24
, Issue.3
, pp. 314-319
-
-
Zhao, R.1
Yin, L.2
Zhao, L.3
|