메뉴 건너뛰기




Volumn 85, Issue 5, 2008, Pages 359-363

Agreement and repeatability of the Sonogage ultrasound pachometer compared with a Mitutoyo micrometer

Author keywords

Orthokeratology; Pachometry; Pachymetry; Polymacon lenses; Ultrasound

Indexed keywords

DISKS (MACHINE COMPONENTS); MEASUREMENT THEORY; MICROMETERS; OPTOMETERS; STATISTICAL METHODS; THICKNESS MEASUREMENT; VISION AIDS;

EID: 43149122695     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/OPX.0b013e31816bf55d     Document Type: Article
Times cited : (4)

References (21)
  • 2
    • 16544367104 scopus 로고    scopus 로고
    • How does the cornea change under corneal reshaping contact lenses?
    • Choo J, Caroline P, Harlin D. How does the cornea change under corneal reshaping contact lenses? Eye Contact Lens 2004;30:211-13.
    • (2004) Eye Contact Lens , vol.30 , pp. 211-213
    • Choo, J.1    Caroline, P.2    Harlin, D.3
  • 5
    • 0038485796 scopus 로고    scopus 로고
    • The effects of overnight orthokeratology lens wear on corneal thickness
    • Alharbi A, Swarbrick HA. The effects of overnight orthokeratology lens wear on corneal thickness. Invest Ophthalmol Vis Sci 2003;44:2518-23.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 2518-2523
    • Alharbi, A.1    Swarbrick, H.A.2
  • 6
    • 16544393168 scopus 로고    scopus 로고
    • What does overnight lens wear do to the corneal epithelium? Is corneal refractive therapy different?
    • Ladage PM. What does overnight lens wear do to the corneal epithelium? Is corneal refractive therapy different? Eye Contact Lens 2004;30:194-7.
    • (2004) Eye Contact Lens , vol.30 , pp. 194-197
    • Ladage, P.M.1
  • 7
    • 0022401943 scopus 로고
    • Determination of corneal thickness using ultrasonic pachometry
    • Kremer FB, Walton P, Gensheimer G. Determination of corneal thickness using ultrasonic pachometry. Ann Ophthalmol 1985;17:506-7.
    • (1985) Ann Ophthalmol , vol.17 , pp. 506-507
    • Kremer, F.B.1    Walton, P.2    Gensheimer, G.3
  • 8
    • 0027958626 scopus 로고
    • Clinical evaluation of a portable ultrasonic and a standard optical pachometer
    • Patel S, Stevenson RW. Clinical evaluation of a portable ultrasonic and a standard optical pachometer. Optom Vis Sci 1994;71:43-6.
    • (1994) Optom Vis Sci , vol.71 , pp. 43-46
    • Patel, S.1    Stevenson, R.W.2
  • 9
    • 0021035876 scopus 로고
    • Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters
    • Salz JJ, Azen SP, Berstein J, Caroline P, Villasenor RA, Schanzlin DJ. Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters. Ophthalmic Surg 1983;14:750-4.
    • (1983) Ophthalmic Surg , vol.14 , pp. 750-754
    • Salz, J.J.1    Azen, S.P.2    Berstein, J.3    Caroline, P.4    Villasenor, R.A.5    Schanzlin, D.J.6
  • 11
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound
    • Lackner B, Schmidinger G, Pieh S, Funovics MA, Skorpik C. Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom Vis Sci 2005;82:892-9.
    • (2005) Optom Vis Sci , vol.82 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3    Funovics, M.A.4    Skorpik, C.5
  • 13
    • 0347355073 scopus 로고    scopus 로고
    • Central corneal thickness as a risk factor for advanced glaucoma damage
    • Herndon LW, Weizer JS, Stinnett SS. Central corneal thickness as a risk factor for advanced glaucoma damage. Arch Ophthalmol 2004;122:17-21.
    • (2004) Arch Ophthalmol , vol.122 , pp. 17-21
    • Herndon, L.W.1    Weizer, J.S.2    Stinnett, S.S.3
  • 15
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Available at:, Accessed January 16, 2008
    • Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Statistician 1983;32:307-17. Available at: http://www-users.york.ac.uk/~mb55/meas/ab83.pdf. Accessed January 16, 2008.
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 33746300231 scopus 로고    scopus 로고
    • Reproducibility of ultrasound pachymetry using the Sonogage Corneo-Gage Plus 2
    • Rah MJ, Deng L, Jackson JM. Reproducibility of ultrasound pachymetry using the Sonogage Corneo-Gage Plus 2. Optometry 2006;77:392-6.
    • (2006) Optometry , vol.77 , pp. 392-396
    • Rah, M.J.1    Deng, L.2    Jackson, J.M.3
  • 21
    • 16544363969 scopus 로고    scopus 로고
    • Corneal and epithelial thickness changes after 4 weeks of overnight corneal refractive therapy lens wear, measured with optical coherence tomography
    • Haque S, Fonn D, Simpson T, Jones L. Corneal and epithelial thickness changes after 4 weeks of overnight corneal refractive therapy lens wear, measured with optical coherence tomography. Eye Contact Lens 2004;30:189-93.
    • (2004) Eye Contact Lens , vol.30 , pp. 189-193
    • Haque, S.1    Fonn, D.2    Simpson, T.3    Jones, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.