메뉴 건너뛰기




Volumn 6913, Issue , 2008, Pages

Measurement of small lesions near metallic implants with megavoltage cone beam CT

Author keywords

Hi Z materials; Hip prostheses imaging; Metal artifact; MVCT; X ray computed tomography

Indexed keywords

COMPUTERIZED TOMOGRAPHY; HIP PROSTHESES; RADIOTHERAPY; SURGERY;

EID: 43149113926     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.773210     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 1
    • 0028798063 scopus 로고
    • The problem is Osteolysis
    • Harris WH. The problem is Osteolysis. CWH Orthop. 1995; 311:46-53.
    • (1995) CWH Orthop , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 2
    • 0031709401 scopus 로고    scopus 로고
    • Predictive value of early radiographic findings in cementless total hip arthroplasty femoral components: An 8- to 12-year follow-up
    • Khalily, C. and LA. Whiteside, Predictive value of early radiographic findings in cementless total hip arthroplasty femoral components: an 8- to 12-year follow-up. J Arthroplasty, 1998.13(7): p. 768-73
    • (1998) J Arthroplasty , vol.13 , Issue.7 , pp. 768-773
    • Khalily, C.1    Whiteside, L.A.2
  • 3
    • 0041633552 scopus 로고    scopus 로고
    • Radiographic definition of pelvic osteolysis following total hip arthroplasty
    • Claus, A.M., et al., Radiographic definition of pelvic osteolysis following total hip arthroplasty. J Bone Joint Surg Am, 2003. 85-A(8): p. 1519-26.
    • (2003) J Bone Joint Surg Am , vol.85-A , Issue.8 , pp. 1519-1526
    • Claus, A.M.1
  • 4
    • 33748313414 scopus 로고    scopus 로고
    • The Use of Megavoltage Cone-Beam CT To Complement CT for Target Definition In Pelvic Radiotherapy In the Presence of Hip Replacement
    • Aubin M., Morin O., Chen J., Gillis A., Pickett B., Aubry J.F., Akazawa C, Speight J., Roach III M. and Pouliot J., "The Use of Megavoltage Cone-Beam CT To Complement CT for Target Definition In Pelvic Radiotherapy In the Presence of Hip Replacement", Br J Radiol. 79: 918-921, 2006.
    • (2006) Br J Radiol , vol.79 , pp. 918-921
    • Aubin, M.1    Morin, O.2    Chen, J.3    Gillis, A.4    Pickett, B.5    Aubry, J.F.6    Akazawa, C.7    Speight, J.8    Roach III, M.9    Pouliot, J.10
  • 5
    • 33748335530 scopus 로고    scopus 로고
    • Image Guided Radiotherapy using Megavoltage Cone-Beam CT for Treatment of Paraspinous Tumors in the Presence of Orthopedic Hardware
    • Hansen E.K., Larson D.A., Morin O., et al., Image Guided Radiotherapy using Megavoltage Cone-Beam CT for Treatment of Paraspinous Tumors in the Presence of Orthopedic Hardware, Int. J. Radiation Oncology Biol. Phys. 66(2), 323-326; 2006.
    • (2006) Int. J. Radiation Oncology Biol. Phys , vol.66 , Issue.2 , pp. 323-326
    • Hansen, E.K.1    Larson, D.A.2    Morin, O.3
  • 6
    • 19944432829 scopus 로고    scopus 로고
    • Low-dose megavoltage cone-beam CT for radiation therapy
    • Pouliot J, Bani-Hashemi A, Chen J, et al. "Low-dose megavoltage cone-beam CT for radiation therapy". Int J Radiat Oncol Biol Phys. 2005;61(2):238-246.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , Issue.2 , pp. 238-246
    • Pouliot, J.1    Bani-Hashemi, A.2    Chen, J.3
  • 7
    • 33644932630 scopus 로고    scopus 로고
    • Megavoltage Cone Beam CT: System Description and Clinical Applications
    • Morin O., Gillis A, Chen J. et al. "Megavoltage Cone Beam CT: System Description and Clinical Applications", Med Dosim. 31:51-61, 2006.
    • (2006) Med Dosim , vol.31 , pp. 51-61
    • Morin, O.1    Gillis, A.2    Chen, J.3
  • 9
    • 41449094240 scopus 로고    scopus 로고
    • Physical Performance and Image quality of Megavoltage Cone-Beam CT
    • O. Morin et al., Physical Performance and Image quality of Megavoltage Cone-Beam CT, Med. Phys. 34, 2572, (2007).
    • (2007) Med. Phys , vol.34 , pp. 2572
    • Morin, O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.