-
1
-
-
0031594091
-
Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
-
Wang A, Essner A, Polineni VK, Stark C, Dumbleton JH. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribol Int 1998;31:17-33.
-
(1998)
Tribol Int
, vol.31
, pp. 17-33
-
-
Wang, A.1
Essner, A.2
Polineni, V.K.3
Stark, C.4
Dumbleton, J.H.5
-
2
-
-
42649129876
-
-
Grobbelaar CJ, Weber FA, Spirakis A, Plessis TD, Cappaert G, Cakic JN. Clinical experience with γ irradiation-cross-linked polyethylene - A 14 to 20 year follow-up report. S Afr Bone Joint Surg 1999;9:140-147.
-
Grobbelaar CJ, Weber FA, Spirakis A, Plessis TD, Cappaert G, Cakic JN. Clinical experience with γ irradiation-cross-linked polyethylene - A 14 to 20 year follow-up report. S Afr Bone Joint Surg 1999;9:140-147.
-
-
-
-
3
-
-
0032927112
-
Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacement
-
McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacement. J Orthop Res 1999;17:157-167.
-
(1999)
J Orthop Res
, vol.17
, pp. 157-167
-
-
McKellop, H.1
Shen, F.W.2
Lu, B.3
Campbell, P.4
Salovey, R.5
-
4
-
-
0032922181
-
Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene
-
Wroblewski BM, Siney PD, Fleming PA. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. J Bone Joint Surg Br 1999;81:54-55.
-
(1999)
J Bone Joint Surg Br
, vol.81
, pp. 54-55
-
-
Wroblewski, B.M.1
Siney, P.D.2
Fleming, P.A.3
-
5
-
-
0033922311
-
Wear of high-dose γ-irradiated polyethylene in total hip replacements
-
Oonishi H, Kadoya Y. Wear of high-dose γ-irradiated polyethylene in total hip replacements. J Orthop Sci 2000;5:223-228.
-
(2000)
J Orthop Sci
, vol.5
, pp. 223-228
-
-
Oonishi, H.1
Kadoya, Y.2
-
6
-
-
0347596747
-
Assessment of wear in extensively irradiated UHMWPE cups in simulator studies
-
Oonishi H, Clarke IC, Yamamoto K, Masaoka T, Fujisawa A, Masuda H. Assessment of wear in extensively irradiated UHMWPE cups in simulator studies. J Biomed Mater Res A 2004;68:52-60.
-
(2004)
J Biomed Mater Res A
, vol.68
, pp. 52-60
-
-
Oonishi, H.1
Clarke, I.C.2
Yamamoto, K.3
Masaoka, T.4
Fujisawa, A.5
Masuda, H.6
-
7
-
-
42649091644
-
Knee simulator wear of cross-linked UHMWPE with normal and mal-rotation kinematics
-
In the Society for Biomaterials, NV
-
Asano T, Clarke IC, Williams P, Akagi M, Shisido T, Mizoue T. Knee simulator wear of cross-linked UHMWPE with normal and mal-rotation kinematics. In the Proceedings of 29th Annual Meeting Society for Biomaterials, NV, 2003, p 307.
-
(2003)
Proceedings of 29th Annual Meeting
, pp. 307
-
-
Asano, T.1
Clarke, I.C.2
Williams, P.3
Akagi, M.4
Shisido, T.5
Mizoue, T.6
-
8
-
-
0019543365
-
Effect of radiation sterilization and aging on ultrahigh molecular weight polyethylene
-
Roe RJ, Grood ES, Shastri R, Grosselin CA, Noyes FR. Effect of radiation sterilization and aging on ultrahigh molecular weight polyethylene. J Biomed Mater Res 1981;15:209-230.
-
(1981)
J Biomed Mater Res
, vol.15
, pp. 209-230
-
-
Roe, R.J.1
Grood, E.S.2
Shastri, R.3
Grosselin, C.A.4
Noyes, F.R.5
-
9
-
-
0028102058
-
Post-irradiation aging of ultra-high molecular weight polyethylene
-
Clare M, Rimnac M, Robert WK, Foster B, Timothy MW. Post-irradiation aging of ultra-high molecular weight polyethylene. J Bone Joint Surg Am 1994;76:1052-1056.
-
(1994)
J Bone Joint Surg Am
, vol.76
, pp. 1052-1056
-
-
Clare, M.1
Rimnac, M.2
Robert, W.K.3
Foster, B.4
Timothy, M.W.5
-
10
-
-
0032486507
-
Comparison of the effects of γ radiation and low temperature hydrogen peroxide gas plasma sterilization on behavior of UHMWPE
-
Goldman M, Pruitt L. Comparison of the effects of γ radiation and low temperature hydrogen peroxide gas plasma sterilization on behavior of UHMWPE. J Biomed Mater Res 1998;40:378-384.
-
(1998)
J Biomed Mater Res
, vol.40
, pp. 378-384
-
-
Goldman, M.1
Pruitt, L.2
-
11
-
-
0033179629
-
Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions
-
Kurtz SM, Pruitt LA, Jewett CW, Foulds JR, Edidin AA. Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions. Biomaterials 1999;20:1449-1462.
-
(1999)
Biomaterials
, vol.20
, pp. 1449-1462
-
-
Kurtz, S.M.1
Pruitt, L.A.2
Jewett, C.W.3
Foulds, J.R.4
Edidin, A.A.5
-
12
-
-
0028129938
-
Current concepts review ultra-high molecular weight polyethylene
-
Li S, Burstein AH. Current concepts review ultra-high molecular weight polyethylene. J Bone Joint Surg Am 1994;76:1080-1090.
-
(1994)
J Bone Joint Surg Am
, vol.76
, pp. 1080-1090
-
-
Li, S.1
Burstein, A.H.2
-
13
-
-
0001200651
-
Influence of ultra high molecular weight polyethylene resin type and manufacturing method on real time oxidation
-
New Orleans, LA
-
Gillis AM, Furman BD, Li S. Influence of ultra high molecular weight polyethylene resin type and manufacturing method on real time oxidation. Read at the 44th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, 1998, p 360.
-
(1998)
Read at the 44th Annual Meeting of the Orthopaedic Research Society
, pp. 360
-
-
Gillis, A.M.1
Furman, B.D.2
Li, S.3
-
14
-
-
0033047781
-
Clinical wear of 63 ultra molecular weight polyethylene acetabular components: Effect of starting resin and forming method
-
James SP, Lee KR, Beauregard GP, Rentfrow ED, McLaughlin JR. Clinical wear of 63 ultra molecular weight polyethylene acetabular components: Effect of starting resin and forming method. J Biomed Mater Res 1999;48:374-384.
-
(1999)
J Biomed Mater Res
, vol.48
, pp. 374-384
-
-
James, S.P.1
Lee, K.R.2
Beauregard, G.P.3
Rentfrow, E.D.4
McLaughlin, J.R.5
-
15
-
-
0029024043
-
Comparison of polyethylene wear in machined versus molded polyethylene
-
Bankston AB, Keating EM, Ranawat C, Faris PM, Ritter MA. Comparison of polyethylene wear in machined versus molded polyethylene. Clin Orthop Relat Res 1995;317:37-43.
-
(1995)
Clin Orthop Relat Res
, vol.317
, pp. 37-43
-
-
Bankston, A.B.1
Keating, E.M.2
Ranawat, C.3
Faris, P.M.4
Ritter, M.A.5
-
16
-
-
0001125458
-
Material and performance differences between retrieved machined and molded Insall/Burtein type total knee arthroplasties
-
San Francisco, CA
-
Furman BD, Awad JN, Chastain KE, Li S. Material and performance differences between retrieved machined and molded Insall/Burtein type total knee arthroplasties. Read at the 43th Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, 1997, p 643.
-
(1997)
Read at the 43th Annual Meeting of the Orthopaedic Research Society
, pp. 643
-
-
Furman, B.D.1
Awad, J.N.2
Chastain, K.E.3
Li, S.4
-
17
-
-
42649121476
-
A comparison of Directory molded and machined retrieved acetabular cups of a single design
-
In the, San Diego, CA
-
Furman BD, Lee CL, Block A, Lefebvre FK, Li S. A comparison of Directory molded and machined retrieved acetabular cups of a single design. In the Proceedings of 29th Annual Meeting Society for Biomaterials, San Diego, CA, 2003, p 443.
-
(2003)
Proceedings of 29th Annual Meeting Society for Biomaterials
, pp. 443
-
-
Furman, B.D.1
Lee, C.L.2
Block, A.3
Lefebvre, F.K.4
Li, S.5
-
18
-
-
0027478984
-
Long-term results of the total condylar knee arthroplasty. 15-year survivorship study
-
Ranawat CS, Flynn WF, Saddler S. Long-term results of the total condylar knee arthroplasty. 15-year survivorship study. Clin Orthop Relat Res 1993;286:94-102.
-
(1993)
Clin Orthop Relat Res
, vol.286
, pp. 94-102
-
-
Ranawat, C.S.1
Flynn, W.F.2
Saddler, S.3
-
21
-
-
0034959851
-
Long-term followup of anatomic graduated components posterior cruciate-retaining total knee replacement
-
Ritter MA, Berend ME, Meding JB, Keating EM, Faris PM, Crites BM. Long-term followup of anatomic graduated components posterior cruciate-retaining total knee replacement. Clin Orthop Relat Res 2001;388:51-57.
-
(2001)
Clin Orthop Relat Res
, vol.388
, pp. 51-57
-
-
Ritter, M.A.1
Berend, M.E.2
Meding, J.B.3
Keating, E.M.4
Faris, P.M.5
Crites, B.M.6
-
23
-
-
0035145862
-
Long-term clinical and radiographic results of a pegged tibial baseplate in primary total knee arthroplasty
-
Miller CW, Pettygrow R. Long-term clinical and radiographic results of a pegged tibial baseplate in primary total knee arthroplasty. J Arthroplasty 2001;16:70-75.
-
(2001)
J Arthroplasty
, vol.16
, pp. 70-75
-
-
Miller, C.W.1
Pettygrow, R.2
-
24
-
-
0034984004
-
Instability after total knee artroplasty with the Miller-Gallante II total knee
-
Mitts K, Muldoon MP, Gladden M, Padgett DE. Instability after total knee artroplasty with the Miller-Gallante II total knee. J Arthroplasty 2001;16:422-427.
-
(2001)
J Arthroplasty
, vol.16
, pp. 422-427
-
-
Mitts, K.1
Muldoon, M.P.2
Gladden, M.3
Padgett, D.E.4
-
25
-
-
0036704094
-
Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design
-
O'Rourke MR, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design. J Bone Joint Surg Am 2002;84:1362-1371.
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 1362-1371
-
-
O'Rourke, M.R.1
Callaghan, J.J.2
Goetz, D.D.3
Sullivan, P.M.4
Johnston, R.C.5
-
26
-
-
0028849719
-
Effect of component fixation method on osteolysis in total knee arthroplasty
-
Ezzet KA, Garcia R, Barrack RL. Effect of component fixation method on osteolysis in total knee arthroplasty. Clin Orthop Relat Res 1995;321:86-91.
-
(1995)
Clin Orthop Relat Res
, vol.321
, pp. 86-91
-
-
Ezzet, K.A.1
Garcia, R.2
Barrack, R.L.3
-
27
-
-
0035169050
-
An algorithm for the posterior cruciate ligament in total knee arthroplasty
-
Lombardi AV, Mallory TH, Fada RA, Hartman JF, Capps SG, Kefauver CA, Adams JB. An algorithm for the posterior cruciate ligament in total knee arthroplasty. Clin Orthop Relat Res 2001;392:75-87.
-
(2001)
Clin Orthop Relat Res
, vol.392
, pp. 75-87
-
-
Lombardi, A.V.1
Mallory, T.H.2
Fada, R.A.3
Hartman, J.F.4
Capps, S.G.5
Kefauver, C.A.6
Adams, J.B.7
-
28
-
-
0033922918
-
Effect of resin type and manufacturing method on wear of polyethylene tibial components
-
Won CH, Rohatgi S, Kraay MJ, Goldberg VM, Rimnac CM. Effect of resin type and manufacturing method on wear of polyethylene tibial components. Clin Orthop Relat Res 2000;376:161-171.
-
(2000)
Clin Orthop Relat Res
, vol.376
, pp. 161-171
-
-
Won, C.H.1
Rohatgi, S.2
Kraay, M.J.3
Goldberg, V.M.4
Rimnac, C.M.5
-
31
-
-
0032774199
-
The Insall-Burstein total knee replacement in osteoarthritis
-
Aglietti P, Buzzi R, Felice RD, Giron F. The Insall-Burstein total knee replacement in osteoarthritis. J Arthroplasty 1999;14:560-565.
-
(1999)
J Arthroplasty
, vol.14
, pp. 560-565
-
-
Aglietti, P.1
Buzzi, R.2
Felice, R.D.3
Giron, F.4
-
32
-
-
0033751999
-
Ten-to-12 year followup of the Insall-Burstein I total knee prosthesis
-
Thadani PJ, Vince KG, Ortaaslan SG, Blackburn DC, Cudiamat CV. Ten-to-12 year followup of the Insall-Burstein I total knee prosthesis. Clin Orthop Relat Res 2000;380:17-29.
-
(2000)
Clin Orthop Relat Res
, vol.380
, pp. 17-29
-
-
Thadani, P.J.1
Vince, K.G.2
Ortaaslan, S.G.3
Blackburn, D.C.4
Cudiamat, C.V.5
-
33
-
-
0021673354
-
Property changes of UHMW polyethylene hip cup endoprostheses during implantation
-
Eyerer P, Ke YC. Property changes of UHMW polyethylene hip cup endoprostheses during implantation. J Biomed Mater Res 1984;18:1137-1151.
-
(1984)
J Biomed Mater Res
, vol.18
, pp. 1137-1151
-
-
Eyerer, P.1
Ke, Y.C.2
-
34
-
-
0035809851
-
Effects of A-P translation and rotation on the wear of UHMWPE in a total knee joint simulator
-
Kawanabe K, Clarke IC, Tamura J, Akagi M, Good VD, Williams PA, Yamamoto K. Effects of A-P translation and rotation on the wear of UHMWPE in a total knee joint simulator. J Biomed Mater Res 2001;54:400-406.
-
(2001)
J Biomed Mater Res
, vol.54
, pp. 400-406
-
-
Kawanabe, K.1
Clarke, I.C.2
Tamura, J.3
Akagi, M.4
Good, V.D.5
Williams, P.A.6
Yamamoto, K.7
-
35
-
-
0036268869
-
Micro-wear patterns on UHMWPE tibial inserts in total knee joint simulation
-
Tamura J, Clarke IC, Kawanabe K, Akagi M, Good VD, Williams PA, Masaoka T, Schroeder D, Oonishi H. Micro-wear patterns on UHMWPE tibial inserts in total knee joint simulation. J Biomed Mater Res 2003;61:218-225.
-
(2003)
J Biomed Mater Res
, vol.61
, pp. 218-225
-
-
Tamura, J.1
Clarke, I.C.2
Kawanabe, K.3
Akagi, M.4
Good, V.D.5
Williams, P.A.6
Masaoka, T.7
Schroeder, D.8
Oonishi, H.9
-
36
-
-
42649110522
-
Oxidized zirconium femoral component reduce polyethylene wear in a knee wear simulator
-
In the, San Francisco, CA
-
Hermida J, Patil S, D'Lima DD, Colwell CW, Ezzet KA. Oxidized zirconium femoral component reduce polyethylene wear in a knee wear simulator. In the 50th Annual Meeting of the American Association of Orthopaedic Surgeons, San Francisco, CA, 2004, p 138.
-
(2004)
50th Annual Meeting of the American Association of Orthopaedic Surgeons
, pp. 138
-
-
Hermida, J.1
Patil, S.2
D'Lima, D.D.3
Colwell, C.W.4
Ezzet, K.A.5
-
37
-
-
0037254896
-
Comparison of the wear properties of polyethylene plate in total knee prostheses (TKP) using different femoral component materials
-
Ueno M, Ikeuchi K, Nakamura T, Akagi M. Comparison of the wear properties of polyethylene plate in total knee prostheses (TKP) using different femoral component materials. Key Eng Mater 2003;15:801-804.
-
(2003)
Key Eng Mater
, vol.15
, pp. 801-804
-
-
Ueno, M.1
Ikeuchi, K.2
Nakamura, T.3
Akagi, M.4
-
38
-
-
0028594009
-
Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components
-
White SE, Whiteside LA, McCarthy DS, Anthony M, Poggie RA. Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components. Clin Orthop Rel Res 1994;309:176-184.
-
(1994)
Clin Orthop Rel Res
, vol.309
, pp. 176-184
-
-
White, S.E.1
Whiteside, L.A.2
McCarthy, D.S.3
Anthony, M.4
Poggie, R.A.5
-
39
-
-
0012563189
-
Markedly improved adhesive wear and delamination resistance with a highly cross-linked UHMWPE for use in total knee arthroplasty
-
In the, USA
-
Muratoglu OK, Bragdon CR, O'Connor D, Perinchief RS, Travers JT, Rubash HE, Harris WH. Markedly improved adhesive wear and delamination resistance with a highly cross-linked UHMWPE for use in total knee arthroplasty. In the 27th Annual Meeting of the Society for Biomaterials, USA, 2001, p 29.
-
(2001)
27th Annual Meeting of the Society for Biomaterials
, pp. 29
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.3
Perinchief, R.S.4
Travers, J.T.5
Rubash, H.E.6
Harris, W.H.7
-
40
-
-
33749866654
-
Wear and toughness if cross-linked polyethylene for total knee replacements: A study using a simulator and small-punch testing
-
Akagi M, Asano T, Clarke IC, Niiyama N, Kyomoto M, Nakamura T, Hamanichi C. Wear and toughness if cross-linked polyethylene for total knee replacements: A study using a simulator and small-punch testing. J Orthop Res 2006;24:2021-2027.
-
(2006)
J Orthop Res
, vol.24
, pp. 2021-2027
-
-
Akagi, M.1
Asano, T.2
Clarke, I.C.3
Niiyama, N.4
Kyomoto, M.5
Nakamura, T.6
Hamanichi, C.7
-
41
-
-
42649090966
-
Hip wear performance of a next generation cross-linked and annealed polyethylene
-
Washington, DC
-
Essner A, Schmidig G, Herrera L, Yau SS, Wang A, Dumbleton JH, Manley MT. Hip wear performance of a next generation cross-linked and annealed polyethylene. Read at the 51st Annual Meeting of the Orthopaedic Research Society, Washington, DC, 2005, p 830.
-
(2005)
Read at the 51st Annual Meeting of the Orthopaedic Research Society
, pp. 830
-
-
Essner, A.1
Schmidig, G.2
Herrera, L.3
Yau, S.S.4
Wang, A.5
Dumbleton, J.H.6
Manley, M.T.7
-
42
-
-
42649134946
-
Sequentially crosslinked and annealed UHMWPE CR knee wear
-
Washington, DC
-
Essner A, Herrera L, Yau SS, Wang A, Dumbleton JH, Manley MT. Sequentially crosslinked and annealed UHMWPE CR knee wear. Read at the 51st Annual Meeting of the Orthopaedic Research Society, Washington, DC, 2005, p 312.
-
(2005)
Read at the 51st Annual Meeting of the Orthopaedic Research Society
, pp. 312
-
-
Essner, A.1
Herrera, L.2
Yau, S.S.3
Wang, A.4
Dumbleton, J.H.5
Manley, M.T.6
-
43
-
-
0006581415
-
Implants for surgery - Wear of total knee-joint prosthesis, Part 1: Loading and displacement parameters for wear - Testing machines with load control and corresponding environment conditions for test
-
ISO, Report No. 14243-1
-
ISO. Implants for surgery - Wear of total knee-joint prosthesis, Part 1: Loading and displacement parameters for wear - Testing machines with load control and corresponding environment conditions for test, 2002. Report No. 14243-1.
-
(2002)
-
-
-
44
-
-
34248168269
-
Implants for surgery - Wear of total knee-joint prostheses, Part 2: Methods of measurement
-
ISO, Report No. 14243-2
-
ISO. Implants for surgery - Wear of total knee-joint prostheses, Part 2: Methods of measurement, 2000. Report No. 14243-2.
-
(2000)
-
-
-
45
-
-
0000398086
-
Friction lubrication and wear of CoCr, Alumina and Zirconia hip prostheses compared on a joint simulator
-
Washington, DC
-
McKellop H, Lu B, Benya P. Friction lubrication and wear of CoCr, Alumina and Zirconia hip prostheses compared on a joint simulator. Read at the Annual Meeting of the Orthopaedic Research Society, Washington, DC, 1992, p 402.
-
(1992)
Read at the Annual Meeting of the Orthopaedic Research Society
, pp. 402
-
-
McKellop, H.1
Lu, B.2
Benya, P.3
-
46
-
-
0032784606
-
Potential thermal artifacts in hip joint wear simulators
-
Lu Z, McKellop H, Liao P, Benya P. Potential thermal artifacts in hip joint wear simulators. J Biomed Mater Res 1999;48:458-464.
-
(1999)
J Biomed Mater Res
, vol.48
, pp. 458-464
-
-
Lu, Z.1
McKellop, H.2
Liao, P.3
Benya, P.4
-
47
-
-
0021910197
-
Fluid-sorption phenomena in sterilized polyethylene acetabular prostheses
-
Clarke IC. Fluid-sorption phenomena in sterilized polyethylene acetabular prostheses. Biomaterials 1985;6:184-188.
-
(1985)
Biomaterials
, vol.6
, pp. 184-188
-
-
Clarke, I.C.1
-
48
-
-
34548707139
-
Highly crosslinked polyethylenes in hip replacements improved wear performance or paradox?
-
Williams PA, Yamamoto K, Masaoka T, Oonishi H, Clarke IC. Highly crosslinked polyethylenes in hip replacements improved wear performance or paradox? Tribol Trans 2007;50:277-290.
-
(2007)
Tribol Trans
, vol.50
, pp. 277-290
-
-
Williams, P.A.1
Yamamoto, K.2
Masaoka, T.3
Oonishi, H.4
Clarke, I.C.5
|