Volumn , Issue , 2007, Pages

Temporal analysis of power system measurements for condition assessment purposes

Author keywords

Condition assessment; Distribution system; Incipient abnormality; Severity; Temporal analysis; Underground cable

Indexed keywords

INTELLIGENT ELECTRONIC DEVICES; ONLINE CURRENT MEASUREMENTS;

EID: 42549165948     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2007.386009     Document Type: Conference Paper
Times cited : (3)

References (23)
  • 1
    • 18844367688 scopus 로고    scopus 로고
    • Time management for assets -chronological strategies for power system asset management
    • May/June
    • M. Shahidehpour and R. Ferrero, "Time management for assets -chronological strategies for power system asset management", IEEE P&EMagazine, vol.3, no.3, May/June 2005, pp. 32-38.
    • (2005) IEEE P&EMagazine , vol.3 , Issue.3 , pp. 32-38
    • Shahidehpour, M.1    Ferrero, R.2
  • 2
    • 0035078363 scopus 로고    scopus 로고
    • Ageing mechanisms and diagnostics for power cables - an overview
    • January, February
    • J. Densley, "Ageing mechanisms and diagnostics for power cables - an overview", IEEE Electrical Insulation Magazine, vol. 17, no. 1, January - February 2001, pp. 14-22.
    • (2001) IEEE Electrical Insulation Magazine , vol.17 , Issue.1 , pp. 14-22
    • Densley, J.1
  • 5
    • 0028758527 scopus 로고    scopus 로고
    • S. M. Miri and A. Privette, A survey of incipient fault detection and location techniques for extruded shielded power cables, presented at the 26th Annual Southeastern Symposium on System Theory, Athens, OH, 1994, pp.402-405.
    • S. M. Miri and A. Privette, "A survey of incipient fault detection and location techniques for extruded shielded power cables", presented at the 26th Annual Southeastern Symposium on System Theory, Athens, OH, 1994, pp.402-405.
  • 9
    • 0020153065 scopus 로고
    • The detection of incipient faults in transmission cables using time domain reflectometry techniques: Technical challenges
    • July
    • W. E. Anderson, J. D. Ramboz, and A. R. Ondrejka, "The detection of incipient faults in transmission cables using time domain reflectometry techniques: Technical challenges", IEEE Transactions on Power Apparatus and Systems, vol. PAS-101, no. 7, July 1982, pp. 1928-1934,
    • (1982) IEEE Transactions on Power Apparatus and Systems , vol.PAS-101 , Issue.7 , pp. 1928-1934
    • Anderson, W.E.1    Ramboz, J.D.2    Ondrejka, A.R.3
  • 10
    • 0024705813 scopus 로고
    • Development of new type insulation diagnostic method for hot-line XLPE cables
    • Jan
    • S. Yamaguchi, S. Soda, and N. Takada, "Development of new type insulation diagnostic method for hot-line XLPE cables", IEEE Transactions on Power Delivery, vol. 4, no. 3, Jan. 1989, pp. 1513-1520.
    • (1989) IEEE Transactions on Power Delivery , vol.4 , Issue.3 , pp. 1513-1520
    • Yamaguchi, S.1    Soda, S.2    Takada, N.3
  • 13
    • 10244221033 scopus 로고    scopus 로고
    • Evaluation of feeder monitoring parameters for incipient fault detection using Laplace trend statistic
    • Nov-Dec
    • C. J. Kim, Seung-Jae Lee, and Sang-Hee Kang, "Evaluation of feeder monitoring parameters for incipient fault detection using Laplace trend statistic", IEEE Transactions on Industry Applications, vol. 40, no. 6, Nov-Dec 2004, pp. 1718-1724.
    • (2004) IEEE Transactions on Industry Applications , vol.40 , Issue.6 , pp. 1718-1724
    • Kim, C.J.1    Lee, S.-J.2    Kang, S.-H.3
  • 14
    • 0242620056 scopus 로고    scopus 로고
    • Identification of symptom parameters for failure anticipation by timed-event trend analysis
    • September
    • C. J. Kim, "Identification of symptom parameters for failure anticipation by timed-event trend analysis", IEEE Power Engineering Review, vol. 20, no. 9, September 2000, pp. 48-49.
    • (2000) IEEE Power Engineering Review , vol.20 , Issue.9 , pp. 48-49
    • Kim, C.J.1
  • 15
    • 0842330546 scopus 로고    scopus 로고
    • Characterization and detection of incipient underground cable failures
    • M.S. thesis, Texas A&M University, College Station, TX
    • R. Chaturbedi, "Characterization and detection of incipient underground cable failures", M.S. thesis, Texas A&M University, College Station, TX, 2002.
    • (2002)
    • Chaturbedi, R.1
  • 16
    • 42549103924 scopus 로고    scopus 로고
    • Underground distribution cable incipient fault diagnosis system
    • Ph. D. dissertation, Texas A&M University, College Station, TX
    • M. J. Mousavi, "Underground distribution cable incipient fault diagnosis system", Ph. D. dissertation, Texas A&M University, College Station, TX, 2005.
    • (2005)
    • Mousavi, M.J.1
  • 17
    • 0036529581 scopus 로고    scopus 로고
    • Expert system for classification and analysis of power system events
    • April
    • E. Styvaktakis, M. H. J. Bollen, and I. Y. H. Gu, "Expert system for classification and analysis of power system events", IEEE Transactions on Power Delivery, vol. 17, no. 2, April 2002, pp. 423-428.
    • (2002) IEEE Transactions on Power Delivery , vol.17 , Issue.2 , pp. 423-428
    • Styvaktakis, E.1    Bollen, M.H.J.2    Gu, I.Y.H.3
  • 19
    • 0842266698 scopus 로고    scopus 로고
    • Classification of load change transients and incipient abnormalities in underground cable using pattern analysis techniques
    • Dallas, TX, Sept
    • M. J. Mousavi and K. L. Butler-Purry, "Classification of load change transients and incipient abnormalities in underground cable using pattern analysis techniques", IEEE/PES Transmission and Distribution Conference, Dallas, TX, Sept. 2003, vol. 1, pp. 175-180.
    • (2003) IEEE/PES Transmission and Distribution Conference , vol.1 , pp. 175-180
    • Mousavi, M.J.1    Butler-Purry, K.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.